메뉴 건너뛰기




Volumn 3149, Issue , 1997, Pages 257-264

X-ray microtomography as a fast three-dimensional imaging technology using a CCD camera coupled with a CdWO4 single-crystal scintillator

Author keywords

CCD; Filtered back projection; Scintillator; Three dimensional image reconstruction; Tomography; X ray

Indexed keywords

CADMIUM; CAMERAS; CCD CAMERAS; CHARGE COUPLED DEVICES; DIAGNOSTIC RADIOGRAPHY; DIGITAL CAMERAS; IMAGE PROCESSING; IMAGE RECONSTRUCTION; IMAGING SYSTEMS; LIGHT EMISSION; LUMINESCENCE; MEDICAL IMAGING; MICROMETERS; MICROSCOPES; RECONSTRUCTION (STRUCTURAL); REPAIR; RESTORATION; SCINTILLATION; SCINTILLATION COUNTERS; THICKNESS MEASUREMENT; THREE DIMENSIONAL COMPUTER GRAPHICS; TOMOGRAPHY; TUNGSTEN COMPOUNDS; X RAYS;

EID: 0001402778     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.279361     Document Type: Conference Paper
Times cited : (30)

References (16)
  • 1
    • 0013412912 scopus 로고
    • Quantitative characterization of damage in a composite material using x-ray tomographic microscopy
    • A.G. Michett, G.R. Morrison, C.J. Buckely, Eds, Springer-Verlag
    • T.M. Breunig, J.C. Elliott, S.R. Stock, P. Anderson, G.R. Davis, and A. Guvenilir, "Quantitative characterization of damage in a composite material using x-ray tomographic microscopy," in X-ray Microscopy III, A.G. Michett, G.R. Morrison, C.J. Buckely, Eds. (Springer-Verlag, 1991), pp. 465-468.
    • (1991) X-ray Microscopy III , pp. 465-468
    • Breunig, T.M.1    Elliott, J.C.2    Stock, S.R.3    Anderson, P.4    Davis, G.R.5    Guvenilir, A.6
  • 2
    • 0011196780 scopus 로고
    • Nondestructive imaging of materials microstructures using x-ray tomographic microscopy
    • J. L. Ackerman and W. A. Ellingson, Eds, Materials Research Society, Pittsburgh, Pennsylvania
    • J.H. Kinney, M.C. Nichols, U. Bonse, S.R. Stock, T.M. Breunig, A. Guvenilir, and R.A. Saroyan, "Nondestructive imaging of materials microstructures using x-ray tomographic microscopy," in Materials Research Society Sym. Proc., vol. 217 J. L. Ackerman and W. A. Ellingson, Eds. (Materials Research Society, Pittsburgh, Pennsylvania, 1990), pp 85-95.
    • (1990) Materials Research Society Sym. Proc , vol.217 , pp. 85-95
    • Kinney, J.H.1    Nichols, M.C.2    Bonse, U.3    Stock, S.R.4    Breunig, T.M.5    Guvenilir, A.6    Saroyan, R.A.7
  • 3
    • 0028580651 scopus 로고
    • Three- dimensional mapping of mineral densities in carious dentin: Theory and method
    • J.H. Kinney, G.W. Marshall Jr., and S.J. Marshall, "Three- dimensional mapping of mineral densities in carious dentin: theory and method," Scanning Microscopy, vol. 8, No. 2, pp. 197-205, 1994.
    • (1994) Scanning Microscopy , vol.8 , Issue.2 , pp. 197-205
    • Kinney, J.H.1    Marshall Jr., G.W.2    Marshall, S.J.3
  • 5
    • 0002185448 scopus 로고
    • High energy high resolution monochromatic x-ray computed tomography using the Photon Factory vertical wiggler beamline
    • Y. Nagata, H. Yamaji, K Hayashi, K. Kawashima, K. Hyodo, H. Kawata, and M. Ando, "High energy high resolution monochromatic x-ray computed tomography using the Photon Factory vertical wiggler beamline," Rev. Sci. Instrum., vol. 63, pp. 615-618, 1992.
    • (1992) Rev. Sci. Instrum , vol.63 , pp. 615-618
    • Nagata, Y.1    Yamaji, H.2    Hayashi, K.3    Kawashima, K.4    Hyodo, K.5    Kawata, H.6    Ando, M.7
  • 6
    • 0000151470 scopus 로고
    • Demonstration of phase-contrast x-ray computed tomography using an x-ray interferometer
    • A. Momose, "Demonstration of phase-contrast x-ray computed tomography using an x-ray interferometer," Nucl. Instrum. Methods A352. pp. 622-628, 1995.
    • (1995) Nucl. Instrum. Methods , vol.A352 , pp. 622-628
    • Momose, A.1
  • 7
    • 58749094803 scopus 로고
    • STXM and cryo-TEM - complementary techniques for 3D image reconstruction of the centriole
    • A.G. Michett, G.R. Morrison, C.J. Buckely, Eds, Springer-Verlag
    • J.M. Kenney, "STXM and cryo-TEM - complementary techniques for 3D image reconstruction of the centriole," in X-ray Microscopy III, A.G. Michett, G.R. Morrison, C.J. Buckely, Eds. (Springer-Verlag, 1991), pp. 481-483.
    • (1991) X-ray Microscopy III , pp. 481-483
    • Kenney, J.M.1
  • 8
    • 0039784824 scopus 로고
    • CCD and vidicon x-ray detectors: Theory and practice (invited)
    • S.M. Gruner, "CCD and vidicon x-ray detectors: Theory and practice (invited)," Rev, Sci. Instrum., vol. 60, pp. 1545-1551, 1989, .
    • (1989) Rev, Sci. Instrum , vol.60 , pp. 1545-1551
    • Gruner, S.M.1
  • 9
    • 0028465205 scopus 로고
    • Hard x-ray imaging with high detection efficiency and high spatial resolution
    • P. Ottonello, G.A. Rottigni, G. Zanella, and R. Zannoni, "Hard x-ray imaging with high detection efficiency and high spatial resolution," Nucl. Instrum. Methods A346, pp. 379-384, 1994.
    • (1994) Nucl. Instrum. Methods , vol.A346 , pp. 379-384
    • Ottonello, P.1    Rottigni, G.A.2    Zanella, G.3    Zannoni, R.4
  • 10
    • 4344591942 scopus 로고
    • Scintillation detectors for CT applications an overview of the history and state-of the-art
    • Seoul, Korea
    • M.R. Farukhi, "Scintillation detectors for CT applications an overview of the history and state-of the-art," Workshop on transmission and emission computed tomography, Seoul, Korea, 1978.
    • (1978) Workshop on transmission and emission computed tomography
    • Farukhi, M.R.1
  • 11
    • 0020319314 scopus 로고
    • Recent developments in scintillation detectors for x-ray CT and positron CT applications
    • M.R. Farukhi, "Recent developments in scintillation detectors for x-ray CT and positron CT applications," IEEE Trans. Nuclear Science, NS-29, pp. 1237-1251, 1982.
    • (1982) IEEE Trans. Nuclear Science , vol.NS-29 , pp. 1237-1251
    • Farukhi, M.R.1
  • 12
    • 0030400199 scopus 로고    scopus 로고
    • Beamline and Exposure Station for Deep X-Ray Lithography at the Advanced Photon Source
    • B. Lai, D.C. Mancini, W. Yun, E. Gluskin, "Beamline and Exposure Station for Deep X-Ray Lithography at the Advanced Photon Source," SPIE Proc. vol. 2880, p. 171, 1996.
    • (1996) SPIE Proc , vol.2880 , pp. 171
    • Lai, B.1    Mancini, D.C.2    Yun, W.3    Gluskin, E.4
  • 13
    • 58749102207 scopus 로고    scopus 로고
    • Calculated from the software developed by 'Center for x-ray Optics' group at Lawrence Berkeley National Laboratory, http://www-cxro.lbl.gov/optical- constants.
    • Calculated from the software developed by 'Center for x-ray Optics' group at Lawrence Berkeley National Laboratory, http://www-cxro.lbl.gov/optical- constants.
  • 14
    • 0022174947 scopus 로고
    • Tomographic imaging with diffracting and non-diffracting sources
    • S. Haykin, J.H. Justice, N.L. Owsley, J.L. Yen, and A.C. Kak, Eds, Prentice-Hall, Inc, Englewood Cliffs, New Jersey
    • A.C. Kak, "Tomographic imaging with diffracting and non-diffracting sources," in Array Signal Processing, S. Haykin, J.H. Justice, N.L. Owsley, J.L. Yen, and A.C. Kak, Eds. (Prentice-Hall, Inc., Englewood Cliffs, New Jersey, 1985), pp. 351-425.
    • (1985) Array Signal Processing , pp. 351-425
    • Kak, A.C.1
  • 15
    • 0006345063 scopus 로고
    • Comparison of the filtered backpropagation and the filtered backprojection algorithms for quantitative tomography
    • T.C. Wedberg, J.J. Stamnes, and W. Singer, "Comparison of the filtered backpropagation and the filtered backprojection algorithms for quantitative tomography," Appl. Opt., vol. 34, No. 28, pp. 6575-6581, 1995.
    • (1995) Appl. Opt , vol.34 , Issue.28 , pp. 6575-6581
    • Wedberg, T.C.1    Stamnes, J.J.2    Singer, W.3
  • 16
    • 0029244830 scopus 로고
    • Reconstruction strategy suited to x-ray diffraction tomography
    • J.A. Grant, M.J. Morgan, J.R. Davis, and P. Wells, "Reconstruction strategy suited to x-ray diffraction tomography," Opt. Soc. Am. A, vol. 12, No. 2, pp. 291-300, 1995.
    • (1995) Opt. Soc. Am. A , vol.12 , Issue.2 , pp. 291-300
    • Grant, J.A.1    Morgan, M.J.2    Davis, J.R.3    Wells, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.