메뉴 건너뛰기




Volumn 73, Issue 16, 1998, Pages 2296-2298

Picojoule and submillisecond calorimetry with micromechanical probes

Author keywords

[No Author keywords available]

Indexed keywords


EID: 0000631370     PISSN: 00036951     EISSN: None     Source Type: Journal    
DOI: 10.1063/1.121802     Document Type: Article
Times cited : (27)

References (12)
  • 7
    • 21944456359 scopus 로고    scopus 로고
    • note
    • According to the procedure described in Ref. 6 we have determined the spring constant with an accuracy of ±20%. The precision of the resonance frequency measurements was ≈25 Hz, which gives the mass detection limit of ≈20 pg for a triangular cantilever and ≈15 pg for a rectangular cantilever.
  • 10
    • 21944456115 scopus 로고    scopus 로고
    • note
    • -1 from the width w=18 μm, length l=185 μm, and the other values the same as above.
  • 11
    • 21944455986 scopus 로고    scopus 로고
    • note
    • -1 was assumed.
  • 12
    • 21944449584 scopus 로고    scopus 로고
    • note
    • -1 for a rectangular cantilever.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.