-
1
-
-
85010163391
-
’x-ray holographic microscopy by means of photoresist recording and atomic-force microscopic readout,’
-
S. Lindaas, M. Howells, C. Jacobsen, and A. Kalinovsky, “X-ray holographic microscopy by means of photoresist recording and atomic-force microscopic readout,” J. Opt. Soc. Am. A 13, 1788–1800 (1996).
-
(1996)
J. Opt. Soc. Am
, vol.A13
, pp. 1788-1800
-
-
Lindaas, S.1
Howells, M.2
Jacobsen, C.3
Kalinovsky, A.4
-
2
-
-
0040418170
-
-
Vol. 67 of Springer Series in Optical Sciences, A. Michette, G. Morrison, and C. Buckley, eds, Springer-Verlag, Berlin
-
K. Kinoshita, T. Matsumura, Y. Inagaki, N. Hirai, M. Sugiyama, H. Kihara, N. Watanabe, Y. Shimanuki, and A. Yagashita, in X-Ray Microscopy HI, Vol. 67 of Springer Series in Optical Sciences, A. Michette, G. Morrison, and C. Buckley, eds. (Springer-Verlag, Berlin, 1992), pp. 335–337.
-
(1992)
X-Ray Microscopy HI
, pp. 335-337
-
-
Kinoshita, K.1
Matsumura, T.2
Inagaki, Y.3
Hirai, N.4
Sugiyama, M.5
Kihara, H.6
Watanabe, N.7
Shimanuki, Y.8
Yagashita, A.9
-
3
-
-
84894394713
-
Development of the computed electroradiography: Trial manufacture of digital imaging system,’
-
Y. Okamoto, T. Oguro, I. Kashima, D. Kanishi, T. Sakurai, and T. Matsuki, “Development of the computed electroradiography: trial manufacture of digital imaging system,” Radiology 185, 395 (1992).
-
(1992)
Radiology
, vol.185
, pp. 395
-
-
Okamoto, Y.1
Oguro, T.2
Kashima, I.3
Kanishi, D.4
Sakurai, T.5
Matsuki, T.6
-
4
-
-
0029489088
-
’towards a micrometer resolution x-ray tomographic microscope
-
W. Yun, ed., Proc. SPIE 2516
-
M. D. Silver, “Towards a micrometer resolution x-ray tomographic microscope,” in X-Ray Microbeam Technology and Applications, W. Yun, ed., Proc. SPIE 2516, 135–147 (1995).
-
(1995)
X-Ray Microbeam Technology and Applications
, pp. 135-147
-
-
Silver, M.D.1
-
5
-
-
0010085685
-
Development of an advanced kirkpatrick-baez microscope,’
-
R. Kodama, N. Ikeda, Y. Kato, Y. Katori, T. Iwai, and K. Takeshi, “Development of an advanced Kirkpatrick-Baez microscope,” Opt. Lett. 21, 1321–1323 (1996).
-
(1996)
Opt. Lett
, vol.21
, pp. 1321-1323
-
-
Kodama, R.1
Ikeda, N.2
Kato, Y.3
Katori, Y.4
Iwai, T.5
Takeshi, K.6
-
6
-
-
0029244659
-
’development of a hard x-ray microscope,’
-
B. Lai, W. Yun, Y. Xiao, L. Yag, D. Legnini, Z. Cai, A. Krasnoperova, F. Cerrina, E. DiFabrizio, L. Grella, and M. Gentili, “Development of a hard x-ray microscope,” Rev. Sci. Instrum. 66, 2287–2289 (1995).
-
(1995)
Rev. Sci. Instrum
, vol.66
, pp. 2287-2289
-
-
Lai, B.1
Yun, W.2
Xiao, Y.3
Yag, L.4
Legnini, D.5
Cai, Z.6
Krasnoperova, A.7
Cerrina, F.8
DiFabrizio, E.9
Grella, L.10
Gentili, M.11
-
7
-
-
0028076309
-
’ultrahigh-resolution x-ray topography
-
W. S. Haddad, I. McNulty, J. E. Trebes, E. H. Anderson, R. A. Levesque, and L. Yang, “Ultrahigh-resolution x-ray topography,” Science 266, 1213–1215 (1994).
-
(1994)
Science
, vol.266
, pp. 1213-1215
-
-
Haddad, W.S.1
McNulty, I.2
Trebes, J.E.3
Anderson, E.H.4
Levesque, R.A.5
Yang, L.6
-
8
-
-
0015655012
-
’calculation of modulation transfer functions of x-ray fluorescent screens,’
-
R. K. Swank, “Calculation of modulation transfer functions of x-ray fluorescent screens,” Appl. Opt. 12, 1865–1870 (1973).
-
(1973)
Appl. Opt
, vol.12
, pp. 1865-1870
-
-
Swank, R.K.1
-
9
-
-
0011288355
-
’x-ray video camera with 10 gm spatial resolution
-
A. Koch and C. Riekel, “X-ray video camera with 10 gm spatial resolution,” Rev. Sci. Instrum. 67, 1737–1740 (1996).
-
(1996)
Rev. Sci. Instrum
, vol.67
, pp. 1737-1740
-
-
Koch, A.1
Riekel, C.2
-
10
-
-
0026777954
-
’preparation and microscopic visualization of multicolor luminescent immunophosphors,’
-
H. B. Beverloo, A. van Schadewijk, J. Bonnet, R. van der Geest, R. Runia, N. P. Verwoerd, J. Vrolijk, J. S. Ploem, and H. J. Tanke, “Preparation and microscopic visualization of multicolor luminescent immunophosphors,” Cytometry 13, 561–570 (1992).
-
(1992)
Cytometry
, vol.13
, pp. 561-570
-
-
Beverloo, H.B.1
Van Schadewijk, A.2
Bonnet, J.3
Van Der Geest, R.4
Runia, R.5
Verwoerd, N.P.6
Vrolijk, J.7
Ploem, J.S.8
Tanke, H.J.9
-
11
-
-
0008230543
-
’a csi(Na) scintillation plate with high spatial resolution,’
-
K. Oba, M. Ito, M. Yamaguchi, and M. Tanaka, “A CsI(Na) scintillation plate with high spatial resolution,” Adv. Electron. Electron Phys. 74, 247–255 (1988).
-
(1988)
Adv. Electron. Electron Phys
, vol.74
, pp. 247-255
-
-
Oba, K.1
Ito, M.2
Yamaguchi, M.3
Tanaka, M.4
-
12
-
-
0023159523
-
’three dimensional x-ray microtomography,’
-
B. P. Flannery, H. W. Deckman, W. G. Roberge, and K. L. d’Amico, “Three dimensional x-ray microtomography,” Science 237, 1439–1444 (1987).
-
(1987)
Science
, vol.237
, pp. 1439-1444
-
-
Flannery, B.P.1
Deckman, H.W.2
Roberge, W.G.3
D’Amico, K.L.4
-
13
-
-
0001660662
-
’microfabrication of cellular phosphors,’
-
H. W. Deckman, J. H. Dunsmuir, and S. M. Gruner, “Microfabrication of cellular phosphors,” J. Vac. Sci. Technol. B 7, 1832–1835 (1989).
-
(1989)
J. Vac. Sci. Technol
, vol.B7
, pp. 1832-1835
-
-
Deckman, H.W.1
Dunsmuir, J.H.2
Gruner, S.M.3
-
14
-
-
9644287761
-
’x-ray tomographic microscopy of fibre-reinforced materials,’
-
U. Bonse, R. Nusshardt, F. Busch, R. Pahl, J. H. Kinney, Q. C. Johnson, R. A. Saroyan, and M. C. Nichols, “X-ray tomographic microscopy of fibre-reinforced materials,” J. Mater. Sci. 26, 4076–4085 (1991).
-
(1991)
J. Mater. Sci
, vol.26
, pp. 4076-4085
-
-
Bonse, U.1
Nusshardt, R.2
Busch, F.3
Pahl, R.4
Kinney, J.H.5
Johnson, Q.C.6
Saroyan, R.A.7
Nichols, M.C.8
-
15
-
-
0011165517
-
’auflosungsvermogen einer mikrotomographie-kamera fur rbntgen-synchrotronstrahlung,’
-
Ph.D. dissertation University of Dortmund, Dortmund, Germany
-
F. Busch, “Auflosungsvermogen einer Mikrotomographie-Kamera fur Rbntgen-Synchrotronstrahlung,” Ph.D. dissertation (University of Dortmund, Dortmund, Germany, 1994).
-
(1994)
-
-
Busch, F.1
-
16
-
-
0002964011
-
’the frequency response of a defocused optical system,’
-
H. H. Hopkins, “The frequency response of a defocused optical system,” Proc. R. Soc. London, Ser. A 231, 91–103 (1955).
-
(1955)
Proc. R. Soc. London, Ser
, vol.A231
, pp. 91-103
-
-
Hopkins, H.H.1
-
18
-
-
0004297165
-
’its version 3.0: The integrated tiger series of coupled electron/photon monte carlo transport codes,’
-
Sandia National Laboratories, Albuquerque, N.M
-
J. L. Halbleib, R. F. Kensek, T. A. Mehlhorn, G. D. Valdez, S. M. Seltzer, and M. J. Berger, “ITS version 3.0: the integrated TIGER series of coupled electron/photon Monte Carlo transport codes,” Rep. SAND91-1634 (Sandia National Laboratories, Albuquerque, N.M., 1988).
-
(1988)
Rep. SAND91-1634
-
-
Halbleib, J.L.1
Kensek, R.F.2
Mehlhorn, T.A.3
Valdez, G.D.4
Seltzer, S.M.5
Berger, M.J.6
-
19
-
-
0001923896
-
’structure and operation of the its code system,’
-
T. M. Jenkins, W. R. Nelson, and A. Rindi, eds. Plenum, New York
-
J. L. Halbleib, “Structure and operation of the ITS code system,” in Monte Carlo Transport of Electrons and Photons, T. M. Jenkins, W. R. Nelson, and A. Rindi, eds. (Plenum, New York, 1987), pp. 249–262.
-
(1987)
Monte Carlo Transport of Electrons and Photons
, pp. 249-262
-
-
Halbleib, J.L.1
-
20
-
-
0003982209
-
’radiation quantities and units,’
-
International Commission on Radiation Units and Measurements (ICRU), ICRU, Washington, D.C
-
International Commission on Radiation Units and Measurements (ICRU), “Radiation quantities and units,” Rep. 33 (ICRU, Washington, D.C., 1980).
-
(1980)
Rep
, vol.33
-
-
-
22
-
-
0002947257
-
’x-ray television area detectors for macromolecular structural studies with synchrotron radiation sources,’
-
U. W. Arndt and D. J. Gilmore, “X-ray television area detectors for macromolecular structural studies with synchrotron radiation sources,” J. Appl. Crystallogr. 12, 1–9 (1979).
-
(1979)
J. Appl. Crystallogr
, vol.12
, pp. 1-9
-
-
Arndt, U.W.1
Gilmore, D.J.2
-
23
-
-
85076019343
-
’scintillating screen-ccd camera using analog on chip storage for time-resolved x-ray absorption spectroscopy,’
-
C. N. Anagnostopoulos and M. P. Lesser, eds., Proc. SPIE 2416
-
A. Koch, M. Hagelstein, A. San Miguel, A. Fontaine, and T. Ressler, “Scintillating screen-CCD camera using analog on chip storage for time-resolved x-ray absorption spectroscopy,” in Cameras and Systems for Electronic Photography and Scientific Imaging, C. N. Anagnostopoulos and M. P. Lesser, eds., Proc. SPIE 2416, 85–93 (1995).
-
(1995)
Cameras and Systems for Electronic Photography and Scientific Imaging
, pp. 85-93
-
-
Koch, A.1
Hagelstein, M.2
San Miguel, A.3
Fontaine, A.4
Ressler, T.5
-
24
-
-
0002118646
-
’scintillation spectrometer statistics,’
-
O. R. Frisch, ed. Pergamon, New York
-
E. Breitenberger, “Scintillation spectrometer statistics,” in Progress in Nuclear Physics, O. R. Frisch, ed. (Pergamon, New York, 1955), Vol. 4, pp. 56–94.
-
(1955)
Progress in Nuclear Physics
, vol.4
, pp. 56-94
-
-
Breitenberger, E.1
-
25
-
-
0000489023
-
’a statistical technique for characterizing xray position-sensitive detectors,’
-
E. Dufresne, R. Bruning, M. Sutton, B. Rodricks, and G. B. Stephenson, “A statistical technique for characterizing xray position-sensitive detectors,” Nucl. Instrum. Methods Phys. Res. A 364, 380–393 (1995).
-
(1995)
Nucl. Instrum. Methods Phys. Res
, vol.A364
, pp. 380-393
-
-
Dufresne, E.1
Bruning, R.2
Sutton, M.3
Rodricks, B.4
Stephenson, G.B.5
-
26
-
-
0029244962
-
’the recent development of bragg-fresnel crystal optics: Experiments and applications at the esrf,’
-
A. Snigirev, “The recent development of Bragg-Fresnel crystal optics: experiments and applications at the ESRF,” Rev. Sci. Instrum. 66, 2053–2058 (1995).
-
(1995)
Rev. Sci. Instrum
, vol.66
, pp. 2053-2058
-
-
Snigirev, A.1
-
27
-
-
0029532089
-
’on the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation,’
-
A. Snigirev, I. Snigireva, V. Kohn, S. Kuznetsov, and I. Schelokov, “On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation,” Rev. Sci. Instrum. 66, 5486–5492 (1995).
-
(1995)
Rev. Sci. Instrum
, vol.66
, pp. 5486-5492
-
-
Snigirev, A.1
Snigireva, I.2
Kohn, V.3
Kuznetsov, S.4
Schelokov, I.5
-
28
-
-
0030247104
-
’phase-contrast microtomography with coherent high-energy synchrotron x-rays,’
-
C. Raven, A. Snigirev, I. Snigireva, P. Spanne, A. Souvorov, and V. Kohn, “Phase-contrast microtomography with coherent high-energy synchrotron x-rays,” Appl. Phys. Lett. 69, 1826–1828 (1996).
-
(1996)
Appl. Phys. Lett
, vol.69
, pp. 1826-1828
-
-
Raven, C.1
Snigirev, A.2
Snigireva, I.3
Spanne, P.4
Souvorov, A.5
Kohn, V.6
-
29
-
-
0029734368
-
’phase objects in synchrotron radiation hard xray imaging,’
-
P. Cloetens, R. Barrett, J. Baruchel, J. Guigney, and M. Schlenker, “Phase objects in synchrotron radiation hard xray imaging,” J. Phys. D 29, 133–146 (1996).
-
(1996)
J. Phys
, vol.D29
, pp. 133-146
-
-
Cloetens, P.1
Barrett, R.2
Baruchel, J.3
Guigney, J.4
Schlenker, M.5
-
30
-
-
0030080445
-
’on the requirements to the instrumentation for the new generation of the synchrotron radiation sources: Beryllium windows,’
-
A. Snigirev, I. Snigireva, V. Kohn, and S. Kuznetzov, “On the requirements to the instrumentation for the new generation of the synchrotron radiation sources: beryllium windows,” Nucl. Instrum. Methods Phys. Res. A 370, 634–640 (1996).
-
(1996)
Nucl. Instrum. Methods Phys. Res
, vol.A370
, pp. 634-640
-
-
Snigirev, A.1
Snigireva, I.2
Kohn, V.3
Kuznetzov, S.4
-
31
-
-
0022307968
-
’a transparent thin-film crt screen of y2o2:Eu with contrast-enhancement layer,’
-
2:Eu with contrast-enhancement layer,” Proc. Soc. Inf. Disp. 27, 139–143 (1986).
-
(1986)
Proc. Soc. Inf. Disp
, vol.27
, pp. 139-143
-
-
Young, R.W.1
Green, B.J.2
Camp, G.H.3
Gibb, I.G.4
Waite, M.S.5
-
32
-
-
0029056032
-
’microtomography with ionizing radiations
-
W. B. Gilboy, “Microtomography with ionizing radiations,” Appl. Radiat. Isot. 46, 689–699 (1995).
-
(1995)
Appl. Radiat. Isot
, vol.46
, pp. 689-699
-
-
Gilboy, W.B.1
-
34
-
-
0039403752
-
’spherical aberration and information content of optical images,’
-
G. Black and E. H. Linfoot, “Spherical aberration and information content of optical images,” Proc. R. Soc. London, Ser. A 239, 522–540 (1957).
-
(1957)
Proc. R. Soc. London, Ser
, vol.A239
, pp. 522-540
-
-
Black, G.1
Linfoot, E.H.2
-
35
-
-
85010145932
-
’spherical aberration in the photometrics system caused by the camera window,’
-
Application Note Photometrics, Tucson, Ariz
-
Photometries, “Spherical aberration in the photometrics system caused by the camera window,” Application Note (Photometrics, Tucson, Ariz., 1990).
-
(1990)
-
-
|