메뉴 건너뛰기




Volumn 75, Issue 10 II, 2004, Pages 4324-4327

Radiation-induced thermoelectric sensitivity (RITES) in ITER prototype magnetic sensors

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRON TRANSITIONS; FREQUENCY RESPONSE; MAGNETIC DEVICES; SENSORS; THERMAL EFFECTS; TOKAMAK DEVICES;

EID: 9944257143     PISSN: 00346748     EISSN: None     Source Type: Journal    
DOI: 10.1063/1.1787580     Document Type: Conference Paper
Times cited : (28)

References (19)
  • 4
    • 0041842597 scopus 로고    scopus 로고
    • The experiments reported in T. Shikama et al., Nucl. Fusion 43, 517 (2003) measured the integrated voltage after a few hundred seconds and so integrator drift could not be distinguished from a small voltage at the output of the coil.
    • (2003) Nucl. Fusion , vol.43 , pp. 517
    • Shikama, T.1
  • 7
    • 9944233572 scopus 로고    scopus 로고
    • Kyoto, November
    • R. Villa and E. Hodgson, in Irradiation Effects in Ceramics for Heating and Current Drive, and Diagnostic Systems, Report EUR-CIEMAT 95, edited by E. Hodgson (CIEMAT, Madrid, 2003), p. 89; see also R. Villa and E. Hodgson, 11th International Conference on Fusion Reactor Materials, Kyoto, November, 2003. [Fusion Eng. Des. (to be published)].
    • (2003) 11th International Conference on Fusion Reactor Materials
    • Villa, R.1    Hodgson, E.2
  • 8
    • 0343564688 scopus 로고    scopus 로고
    • to be published
    • R. Villa and E. Hodgson, in Irradiation Effects in Ceramics for Heating and Current Drive, and Diagnostic Systems, Report EUR-CIEMAT 95, edited by E. Hodgson (CIEMAT, Madrid, 2003), p. 89; see also R. Villa and E. Hodgson, 11th International Conference on Fusion Reactor Materials, Kyoto, November, 2003. [Fusion Eng. Des. (to be published)].
    • Fusion Eng. Des.
  • 10
    • 0343564688 scopus 로고    scopus 로고
    • to be published
    • T. Nishitani et al., 11th International Conference on Fusion Reactor Materials, Kyoto, November, 2003; [Fusion Eng. Des. (to be published)].
    • Fusion Eng. Des.
  • 12
    • 9944228220 scopus 로고    scopus 로고
    • note
    • To reach similar conditions for coil B required currents in excess of the safe current carrying capacity of the (sealed) MIC to instrument cable junctions.
  • 13
    • 9944245054 scopus 로고    scopus 로고
    • note
    • The core material used was >99.99%Cu. Nonuniform work hardening during MIC and coil manufacture could have contributed to the initial (relatively low) sensitivity.
  • 18
    • 9944224276 scopus 로고    scopus 로고
    • note
    • In addition to the results cited in this article, there is a large body of work documenting thermoelectric variations arising in thermocouple pairs due to irradiation, most exhibiting significant sensitivity to neutron fluence.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.