-
1
-
-
0023239950
-
Evaluation of hydroxylapatite-coated titanium dental implants in dogs
-
Block MS, Kent JN, Kay JF. Evaluation of hydroxylapatite-coated titanium dental implants in dogs. J Oral Maxillofac Surg 1987;45:601-607.
-
(1987)
J Oral Maxillofac Surg
, vol.45
, pp. 601-607
-
-
Block, M.S.1
Kent, J.N.2
Kay, J.F.3
-
3
-
-
0023688524
-
Hydroxyapatite-coated titanium for orthopedic implant applications
-
Cook SD, Thomas KA, Kay JF, Jarcho M. Hydroxyapatite-coated titanium for orthopedic implant applications. Clin Orthop 1988;232:225-243.
-
(1988)
Clin Orthop
, vol.232
, pp. 225-243
-
-
Cook, S.D.1
Thomas, K.A.2
Kay, J.F.3
Jarcho, M.4
-
4
-
-
0023982042
-
Calcium phosphate-coated porous titanium implants for enhanced skeletal fixation
-
Rivero DP, Fox J, Skipor AK, Urban RM, Galante JO. Calcium phosphate-coated porous titanium implants for enhanced skeletal fixation. J Biomed Mater Res 1988;22:191-201.
-
(1988)
J Biomed Mater Res
, vol.22
, pp. 191-201
-
-
Rivero, D.P.1
Fox, J.2
Skipor, A.K.3
Urban, R.M.4
Galante, J.O.5
-
5
-
-
0025082451
-
Hydroxyapatite coating enhances fixation of porous coated implants. A comparison in dogs between press fit and noninterference fit
-
Soballe K, Hansen ES, Brockstedt-Rasmussen H, Pedersen CM, Hunger C. Hydroxyapatite coating enhances fixation of porous coated implants. A comparison in dogs between press fit and noninterference fit. Acta Orthop Scand 1990;61:299-306.
-
(1990)
Acta Orthop Scand
, vol.61
, pp. 299-306
-
-
Soballe, K.1
Hansen, E.S.2
Brockstedt-Rasmussen, H.3
Pedersen, C.M.4
Hunger, C.5
-
6
-
-
0025900565
-
Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs
-
Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mater Res 1991;25:889-902.
-
(1991)
J Biomed Mater Res
, vol.25
, pp. 889-902
-
-
Buser, D.1
Schenk, R.K.2
Steinemann, S.3
Fiorellini, J.P.4
Fox, C.H.5
Stich, H.6
-
7
-
-
0026206791
-
Histologic evaluation of the osseous adaptation to titanium and hydroxyapatite-coated titanium implants
-
Jansen JA, van de Waerden JP, Wolke JG, de Groot K. Histologic evaluation of the osseous adaptation to titanium and hydroxyapatite-coated titanium implants. J Biomed Mater Res 1991;25:973-989.
-
(1991)
J Biomed Mater Res
, vol.25
, pp. 973-989
-
-
Jansen, J.A.1
Van De Waerden, J.P.2
Wolke, J.G.3
De Groot, K.4
-
8
-
-
0026300431
-
Histomorphometric studies of hydroxylapatite-coated and uncoated CP titanium threaded implants in bone
-
Gottlander M, Albrektsson T. Histomorphometric studies of hydroxylapatite-coated and uncoated CP titanium threaded implants in bone. Int J Oral Maxillofac Imp 1991;6:339-404.
-
(1991)
Int J Oral Maxillofac Imp
, vol.6
, pp. 339-404
-
-
Gottlander, M.1
Albrektsson, T.2
-
9
-
-
0027637392
-
A histomorphometric study on osteoconduction and osseointegration of titanium alloy with and without plasma-sprayed hydroxyapatite coating using back scattered electron images
-
Wang BC, Chang E, Yang CY, Tu D. A histomorphometric study on osteoconduction and osseointegration of titanium alloy with and without plasma-sprayed hydroxyapatite coating using back scattered electron images. J Mater Sci Mater Med 1993;4:394-403.
-
(1993)
J Mater Sci Mater Med
, vol.4
, pp. 394-403
-
-
Wang, B.C.1
Chang, E.2
Yang, C.Y.3
Tu, D.4
-
10
-
-
0027686549
-
The shear strength and the failure mode of plasma-sprayed hydroxyapatite coating to bone: The effect of coating thickness
-
Wang BC, Lee TM, Chang E, Yang CY. The shear strength and the failure mode of plasma-sprayed hydroxyapatite coating to bone: the effect of coating thickness. J Biomed Mater Res 1993;27:1315-1327.
-
(1993)
J Biomed Mater Res
, vol.27
, pp. 1315-1327
-
-
Wang, B.C.1
Lee, T.M.2
Chang, E.3
Yang, C.Y.4
-
11
-
-
0025608937
-
Hydroxyapatite-coated total hip prostheses. Two-year clinical and roentgenographic results of 100 cases
-
Geesink RG. Hydroxyapatite-coated total hip prostheses. Two-year clinical and roentgenographic results of 100 cases. Clin Orthop 1990;61:39-58.
-
(1990)
Clin Orthop
, vol.61
, pp. 39-58
-
-
Geesink, R.G.1
-
12
-
-
0026352034
-
Hydroxyapatite-coated femoral stems. Histological analysis of components retrieved at autopsy
-
Bauer TW, Geesink RC, Zimmerman R, McMahon JT. Hydroxyapatite-coated femoral stems. Histological analysis of components retrieved at autopsy. J Bone Joint Surg 1991;73A: 1439-1452.
-
(1991)
J Bone Joint Surg
, vol.73 A
, pp. 1439-1452
-
-
Bauer, T.W.1
Geesink, R.C.2
Zimmerman, R.3
McMahon, J.T.4
-
14
-
-
0028918271
-
Comparison of bone-implant interface shear strength of hydroxyapatite-coated and alumina-coated metal implants
-
Inadome T, Hayashi K, Nakashima Y, Tsumura H, Sugioka Y. Comparison of bone-implant interface shear strength of hydroxyapatite-coated and alumina-coated metal implants. J Biomed Mater Res 1995;29:19-24.
-
(1995)
J Biomed Mater Res
, vol.29
, pp. 19-24
-
-
Inadome, T.1
Hayashi, K.2
Nakashima, Y.3
Tsumura, H.4
Sugioka, Y.5
-
15
-
-
0028533742
-
Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength
-
Hayashi K, Inadome T, Tsumura H, Nakashima Y, Sugioka Y. Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength. Biomaterials 1994;15:1187-1191.
-
(1994)
Biomaterials
, vol.15
, pp. 1187-1191
-
-
Hayashi, K.1
Inadome, T.2
Tsumura, H.3
Nakashima, Y.4
Sugioka, Y.5
-
19
-
-
0031125279
-
Plasma spraying of Zirconia-reinforced hydroxyapatite composite coatings on titanium, part I: Phase, microstructure and bonding strength
-
Chang E, Chang WJ, Wang BC, Yang CY. Plasma spraying of Zirconia-reinforced hydroxyapatite composite coatings on titanium, part I: phase, microstructure and bonding strength. J Mater Sci Mater Med 1997;8:193-200.
-
(1997)
J Mater Sci Mater Med
, vol.8
, pp. 193-200
-
-
Chang, E.1
Chang, W.J.2
Wang, B.C.3
Yang, C.Y.4
-
20
-
-
0031117752
-
Plasma spraying of Zirconia-reinforced hydroxyapatite composite coatings on titanium, part II: Dissolution behaviour in simulated body fluid and bonging degradation
-
Chang E, Chang WJ, Wang BC, Yang CY. Plasma spraying of Zirconia-reinforced hydroxyapatite composite coatings on titanium, part II: dissolution behaviour in simulated body fluid and bonging degradation. J Mater Sci Mater Med 1997;8:201-211.
-
(1997)
J Mater Sci Mater Med
, vol.8
, pp. 201-211
-
-
Chang, E.1
Chang, W.J.2
Wang, B.C.3
Yang, C.Y.4
-
22
-
-
0028380652
-
Characterization of plasma-sprayed bioactive hydroxyapatite coatings-in vitro and in vivo
-
Wang BC, Chang E, Yang CY. Characterization of plasma-sprayed bioactive hydroxyapatite coatings-in vitro and in vivo. Mater Chem Phys 1994;37:55-63.
-
(1994)
Mater Chem Phys
, vol.37
, pp. 55-63
-
-
Wang, B.C.1
Chang, E.2
Yang, C.Y.3
-
23
-
-
0031195206
-
Intramedullary implant of plasma-sprayed hydroxyapatite coating: An interface study
-
Yang CY, Wang BC, Lee TM, Chang E, Chang GL. Intramedullary implant of plasma-sprayed hydroxyapatite coating: an interface study. J Biomed Mater Res 1997;36:39-48.
-
(1997)
J Biomed Mater Res
, vol.36
, pp. 39-48
-
-
Yang, C.Y.1
Wang, B.C.2
Lee, T.M.3
Chang, E.4
Chang, G.L.5
-
24
-
-
0032143828
-
Development of plasma-sprayed bioceramic coatings with bond coats based on titania and zirconia
-
Kurzweg H, Heimann RB, Troczynski T, Wayman ML. Development of plasma-sprayed bioceramic coatings with bond coats based on titania and zirconia. Biomaterials 1998;19:1507-1511.
-
(1998)
Biomaterials
, vol.19
, pp. 1507-1511
-
-
Kurzweg, H.1
Heimann, R.B.2
Troczynski, T.3
Wayman, M.L.4
-
25
-
-
0036096721
-
Plasma-sprayed zirconia bond coat as an intermediate layer for hydroxyapatite coating on titanium alloy substrate
-
Chou BY, Chang E. Plasma-sprayed zirconia bond coat as an intermediate layer for hydroxyapatite coating on titanium alloy substrate. J Mater Sci Mater Med 2002;13:589-595.
-
(2002)
J Mater Sci Mater Med
, vol.13
, pp. 589-595
-
-
Chou, B.Y.1
Chang, E.2
-
26
-
-
0036510608
-
Phase transformation during plasma spraying of hydroxyapatite-10-wt%- zirconia composite coating
-
Chou BY, Chang E, Yao SY, Chen JM. Phase transformation during plasma spraying of hydroxyapatite-10-wt%-zirconia composite coating. J Am Ceram Soc 2002;85:661-669.
-
(2002)
J Am Ceram Soc
, vol.85
, pp. 661-669
-
-
Chou, B.Y.1
Chang, E.2
Yao, S.Y.3
Chen, J.M.4
-
27
-
-
0002837465
-
Bonding mechanism of bioactive glass-ceramic A-W to living bone
-
Yamamuro T, Hench LL, Wilson J, editors. Boca Raton, (FL: CRC Press
-
Kokubo T. Bonding Mechanism of Bioactive Glass-Ceramic A-W to living Bone. In: Yamamuro T, Hench LL, Wilson J, editors. CRC Handbook of Bioactive Ceramics. Boca Raton, (FL: CRC Press, 1990, pp 41-49.
-
(1990)
CRC Handbook of Bioactive Ceramics
, pp. 41-49
-
-
Kokubo, T.1
-
28
-
-
0025978275
-
Bioactive glass ceramics: Properties and applications
-
Kokubo T. Bioactive glass ceramics: properties and applications. Biomaterials 1991;12:155-163.
-
(1991)
Biomaterials
, vol.12
, pp. 155-163
-
-
Kokubo, T.1
-
30
-
-
0020715034
-
The interface of various glasses and glass ceramics with a bony implantation bed
-
Gross U, Strunz V. The interface of various glasses and glass ceramics with a bony implantation bed. J Biomed Mater Res 1985;19:251-271.
-
(1985)
J Biomed Mater Res
, vol.19
, pp. 251-271
-
-
Gross, U.1
Strunz, V.2
-
31
-
-
0019568989
-
The ultrastructure of the interface between a glass ceramic and bone
-
Gross U, Brandes J, Strunz V, Bab I, Sela J. The ultrastructure of the interface between a glass ceramic and bone. J Biomed Mater Res 1981;15:291-305.
-
(1981)
J Biomed Mater Res
, vol.15
, pp. 291-305
-
-
Gross, U.1
Brandes, J.2
Strunz, V.3
Bab, I.4
Sela, J.5
-
32
-
-
0019067118
-
The anchoring of glass ceramics of different solubility in the femur of the rat
-
Gross UM, Strunz V. The anchoring of glass ceramics of different solubility in the femur of the rat. J Biomed Mater Res 1980;14:607-618.
-
(1980)
J Biomed Mater Res
, vol.14
, pp. 607-618
-
-
Gross, U.M.1
Strunz, V.2
-
33
-
-
0028447641
-
Cytotoxicity investigations of plasma sprayed calcium phosphate coatings
-
Lugscheider E, Knepper M, Heimberg B, Dekker A, Kirkpatrick CJ. Cytotoxicity investigations of plasma sprayed calcium phosphate coatings. J Mater Sci Mater Med 1994;5:371-375.
-
(1994)
J Mater Sci Mater Med
, vol.5
, pp. 371-375
-
-
Lugscheider, E.1
Knepper, M.2
Heimberg, B.3
Dekker, A.4
Kirkpatrick, C.J.5
|