메뉴 건너뛰기




Volumn 94, Issue 3, 1996, Pages 452-459

Insights from three-dimensional echocardiographic laser stereolithography: Effect of leaflet funnel geometry on the coefficient of orifice contraction, pressure loss, and the Gorlin formula in mitral stenosis

Author keywords

echocardiography; mitral valve; pressure; stenosis

Indexed keywords

ARTICLE; ECHOCARDIOGRAPHY; LASER; MITRAL VALVE STENOSIS; PRIORITY JOURNAL; STATISTICAL ANALYSIS; THREE DIMENSIONAL IMAGING;

EID: 9444229892     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.CIR.94.3.452     Document Type: Article
Times cited : (49)

References (49)
  • 1
    • 0020421192 scopus 로고
    • Dynamic three-dimensional echocardiographic reconstruction of the intact human left ventricle: Technique and initial observations in patients
    • Geiser EA, Ariet M. Conetta DA, Lupkiewicz SM, Christie LG Jr, Conti CR. Dynamic three-dimensional echocardiographic reconstruction of the intact human left ventricle: technique and initial observations in patients. Am Heart J. 1982;103:1056-1065.
    • (1982) Am Heart J , vol.103 , pp. 1056-1065
    • Geiser, E.A.1    Ariet, M.2    Conetta, D.A.3    Lupkiewicz, S.M.4    Christie Jr., L.G.5    Conti, C.R.6
  • 2
    • 0020335046 scopus 로고
    • Three-dimensional reconstruction of echocardiographic images using the, rotation method
    • Ghosh A. Nanda NC, Maurer G. Three-dimensional reconstruction of echocardiographic images using the, rotation method. Ultrasound Med Biol. 1982;8:655-661.
    • (1982) Ultrasound Med Biol , vol.8 , pp. 655-661
    • Ghosh, A.1    Nanda, N.C.2    Maurer, G.3
  • 5
    • 0023593495 scopus 로고
    • Left ventricular shape, wall thickness, and function based on three-dimensional reconstruction echocardiography
    • Sapoznikov D, Fine DG, Mosseri M, Gotsman MS. Left ventricular shape, wall thickness, and function based on three-dimensional reconstruction echocardiography. Comput Cardiol. 1981;495-498.
    • (1981) Comput Cardiol , pp. 495-498
    • Sapoznikov, D.1    Fine, D.G.2    Mosseri, M.3    Gotsman, M.S.4
  • 7
    • 0024337891 scopus 로고
    • Measurement of left ventricular ejection fraction and volumes with three-dimensional reconstructed transesophageal ultrasound scans: Comparison to radio-nuclide dilution measurements
    • Martin RM, Graham MM, Kao R. Bashein G. Measurement of left ventricular ejection fraction and volumes with three-dimensional reconstructed transesophageal ultrasound scans: comparison to radio-nuclide dilution measurements. J Cardiothorac Vasc Anesth. 1989;3: 260-268.
    • (1989) J Cardiothorac Vasc Anesth , vol.3 , pp. 260-268
    • Martin, R.M.1    Graham, M.M.2    Kao, R.3    Bashein, G.4
  • 8
    • 0024423585 scopus 로고
    • Three-dimensional echocardio-graphic reconstruction of the mitral valve, with implications for the diagnosis of mitral valve prolapse
    • Levine RA, Handschumacher MD, Sanfilippo AJ, Hagege AA, Harrigan P, Marshall JE, Weyman AE. Three-dimensional echocardio-graphic reconstruction of the mitral valve, with implications for the diagnosis of mitral valve prolapse. Circulation. 1989;80:589-598.
    • (1989) Circulation , vol.80 , pp. 589-598
    • Levine, R.A.1    Handschumacher, M.D.2    Sanfilippo, A.J.3    Hagege, A.A.4    Harrigan, P.5    Marshall, J.E.6    Weyman, A.E.7
  • 9
    • 0025144490 scopus 로고
    • Three-dimensional spatial registration and interactive display of position and orientation of real-time ultrasound images
    • King DL, King DL Jr, Shao MYC. Three-dimensional spatial registration and interactive display of position and orientation of real-time ultrasound images. J Ultrasound Med. 1990;9:525-532.
    • (1990) J Ultrasound Med , vol.9 , pp. 525-532
    • King, D.L.1    King Jr., D.L.2    Shao, M.Y.C.3
  • 10
    • 0026831209 scopus 로고
    • Three-dimensional echocardiographic volume computation by polyhedral surface reconstruction: In vitro validation and comparison to magnetic resonance imaging
    • Gopal AS, King DL, Katz J, Boxt LM, King DL Jr, Shao MY. Three-dimensional echocardiographic volume computation by polyhedral surface reconstruction: in vitro validation and comparison to magnetic resonance imaging. J Am Soc Echocardiogr. 1992;5:115-124.
    • (1992) J Am Soc Echocardiogr , vol.5 , pp. 115-124
    • Gopal, A.S.1    King, D.L.2    Katz, J.3    Boxt, L.M.4    King Jr., D.L.5    Shao, M.Y.6
  • 11
  • 12
  • 13
    • 50449114923 scopus 로고
    • Hydraulic formula for calculations of the area of the stenotic mitral valve, other cardiac valves, and central circulation shunts
    • Gorlin R, Gorlin SG. Hydraulic formula for calculations of the area of the stenotic mitral valve, other cardiac valves, and central circulation shunts. Am Heart J. 1951;41:1-29.
    • (1951) Am Heart J , vol.41 , pp. 1-29
    • Gorlin, R.1    Gorlin, S.G.2
  • 14
    • 0015477999 scopus 로고
    • Modified orifice equation for the calculations of mitral valve area
    • Cohen MV, Gorlin R. Modified orifice equation for the calculations of mitral valve area. Am Heart J. 1972;84:839-840.
    • (1972) Am Heart J , vol.84 , pp. 839-840
    • Cohen, M.V.1    Gorlin, R.2
  • 15
    • 0025156756 scopus 로고
    • A generalized formulation of the Gorlin formula for calculating the area of the stenotic mitral valve and other stenotic cardiac valves
    • Gorlin WB, Gorlin R. A generalized formulation of the Gorlin formula for calculating the area of the stenotic mitral valve and other stenotic cardiac valves. J Am Coll Cardiol. 1990;15:246-247.
    • (1990) J Am Coll Cardiol , vol.15 , pp. 246-247
    • Gorlin, W.B.1    Gorlin, R.2
  • 18
    • 0011095349 scopus 로고
    • Stenosis: Theoretical background and clinical measurements
    • Sugawara M, Kajiya F, Kitabatake A, Matsuo H, eds. Tokyo, Japan: Springer-Verlag
    • Sugawara M. Stenosis: theoretical background and clinical measurements. In: Sugawara M, Kajiya F, Kitabatake A, Matsuo H, eds. Blood Flow in the Heart and Large Vessels. Tokyo, Japan: Springer-Verlag; 1989:105-131.
    • (1989) Blood Flow in the Heart and Large Vessels , pp. 105-131
    • Sugawara, M.1
  • 19
    • 0025232311 scopus 로고
    • Influence of orifice geometry and flow rate on effective valve area: An in vitro study
    • Flachskampf FA, Weyman AE, Guererro JL, Thomas JD. Influence of orifice geometry and flow rate on effective valve area: an in vitro study. J Am Coll Cardiol. 1990;15:1173-1180.
    • (1990) J Am Coll Cardiol , vol.15 , pp. 1173-1180
    • Flachskampf, F.A.1    Weyman, A.E.2    Guererro, J.L.3    Thomas, J.D.4
  • 21
    • 0022656302 scopus 로고
    • Studies in vitro of the relationship between ultrasound and laser Doppler velocimetry and applicability of the simplified Bernoulli relationship
    • Valdes-Cruz LM, Yoganathan AP, Tamura T, Tomizuka F, Woo YR, Sahn DJ. Studies in vitro of the relationship between ultrasound and laser Doppler velocimetry and applicability of the simplified Bernoulli relationship. Circulation. 1986;73:300-308.
    • (1986) Circulation , vol.73 , pp. 300-308
    • Valdes-Cruz, L.M.1    Yoganathan, A.P.2    Tamura, T.3    Tomizuka, F.4    Woo, Y.R.5    Sahn, D.J.6
  • 23
    • 0023427268 scopus 로고
    • Calculations of cardiac valve stenosis: Restoring an old concept for advanced applications
    • Gorlin R. Calculations of cardiac valve stenosis: restoring an old concept for advanced applications. J Am Coll Cardiol. 1987;10:920-923.
    • (1987) J Am Coll Cardiol , vol.10 , pp. 920-923
    • Gorlin, R.1
  • 25
    • 0023180964 scopus 로고
    • When should Doppler-determined valve area be better than the Gorlin formula? Variation in hydraulic constants in low flow states
    • Segal J, Lerner DJ, Miller DC, Mitchell RS, Alderman EA, Popp RL. When should Doppler-determined valve area be better than the Gorlin formula? Variation in hydraulic constants in low flow states. J Am Coil Cardiol. 1987;9:1294-1305.
    • (1987) J Am Coil Cardiol , vol.9 , pp. 1294-1305
    • Segal, J.1    Lerner, D.J.2    Miller, D.C.3    Mitchell, R.S.4    Alderman, E.A.5    Popp, R.L.6
  • 26
    • 0027400525 scopus 로고
    • A new integrated system for three-dimensional reconstruction: Development and validation for ventricular volume with application in human subjects
    • Handschumacher MD, Lethor JP, Siu SC, Mele D, Rivera JM, Picard MH, Weyman AE, Levine RA. A new integrated system for three-dimensional reconstruction: development and validation for ventricular volume with application in human subjects. J Am Coll Cardiol. 1993;21:743-753.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 743-753
    • Handschumacher, M.D.1    Lethor, J.P.2    Siu, S.C.3    Mele, D.4    Rivera, J.M.5    Picard, M.H.6    Weyman, A.E.7    Levine, R.A.8
  • 27
    • 0027367635 scopus 로고
    • Three-dimensional echocardiographic measurements of left ventricular volume in vitro: Comparison with two-dimensional echocardiography and cineventriculography
    • Sapin PM, Schroeder KD, Smith MD, DeMaria AN, King DL. Three-dimensional echocardiographic measurements of left ventricular volume in vitro: comparison with two-dimensional echocardiography and cineventriculography. J Am Coll Cardiol. 1993;22:1530-1537.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1530-1537
    • Sapin, P.M.1    Schroeder, K.D.2    Smith, M.D.3    DeMaria, A.N.4    King, D.L.5
  • 29
    • 0028094704 scopus 로고
    • Comparison of two- And three-dimensional echocardiography with cineventriculography for measurement of the left ventricular volume
    • Sapin PM, Schroder KM, Gopal AS, Smith MD, DeMaria AN, King DL. Comparison of two- and three-dimensional echocardiography with cineventriculography for measurement of the left ventricular volume. J Am Coll Cardiol. 1994;24:1054-1063.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 1054-1063
    • Sapin, P.M.1    Schroder, K.M.2    Gopal, A.S.3    Smith, M.D.4    DeMaria, A.N.5    King, D.L.6
  • 35
    • 0023710752 scopus 로고
    • Percutaneous balloon dilatation of the mitral valve: An analysis of echocardiographic variables related to outcome and the mechanism of dilatation
    • Wilkins GT, Weyman AE, Abascal VM, Block PC, Palacios IF. Percutaneous balloon dilatation of the mitral valve: an analysis of echocardiographic variables related to outcome and the mechanism of dilatation. Br Heart J. 1988;60:299-308.
    • (1988) Br Heart J , vol.60 , pp. 299-308
    • Wilkins, G.T.1    Weyman, A.E.2    Abascal, V.M.3    Block, P.C.4    Palacios, I.F.5
  • 36
    • 0024437454 scopus 로고
    • Influence of mitral valve morphology on double-balloon catheter valvuloplasty in patients with mitral stenosis
    • Reid CL, Chandraratna AN, Kawanishi DT, Kotlewski A, Rahim-toola SH. Influence of mitral valve morphology on double-balloon catheter valvuloplasty in patients with mitral stenosis. Circulation. 1989;80:515-524.
    • (1989) Circulation , vol.80 , pp. 515-524
    • Reid, C.L.1    Chandraratna, A.N.2    Kawanishi, D.T.3    Kotlewski, A.4    Rahim-toola, S.H.5
  • 37
    • 0000089520 scopus 로고
    • The spectrum of pure mitral stenosis: Hemodynamic studies in relation to clinical disability
    • Hugenholtz PG, Ryan TJ, Stein SW, Abelmann WH. The spectrum of pure mitral stenosis: hemodynamic studies in relation to clinical disability. Am J Cardiol. 1962;10:773-784.
    • (1962) Am J Cardiol , vol.10 , pp. 773-784
    • Hugenholtz, P.G.1    Ryan, T.J.2    Stein, S.W.3    Abelmann, W.H.4
  • 38
    • 9444241098 scopus 로고
    • Proximal isovelocity surface area method applied to non-planar surfaces in a pulsatile flow system: In vitro studies simulating clinical regurgitation
    • Abstract
    • Tsuji S, Reid CL, Cape EG, Chuang MY, Joung K, Kalthia A, Gardin JM. Proximal isovelocity surface area method applied to non-planar surfaces in a pulsatile flow system: in vitro studies simulating clinical regurgitation. J Am Soc Echocardiogr. 1995;8:351. Abstract.
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 351
    • Tsuji, S.1    Reid, C.L.2    Cape, E.G.3    Chuang, M.Y.4    Joung, K.5    Kalthia, A.6    Gardin, J.M.7
  • 39
    • 0028959713 scopus 로고
    • Comparison of valvular resistance, stroke work loss, and Gorlin valve area for quantification of aortic stenosis
    • Voelker W, Reul H, Nienhaus G, Stelzer T, Schmitz B, Steegers A, Karsch KR. Comparison of valvular resistance, stroke work loss, and Gorlin valve area for quantification of aortic stenosis. Circulation. 1995;91:1196-1204.
    • (1995) Circulation , vol.91 , pp. 1196-1204
    • Voelker, W.1    Reul, H.2    Nienhaus, G.3    Stelzer, T.4    Schmitz, B.5    Steegers, A.6    Karsch, K.R.7
  • 40
    • 0025793356 scopus 로고
    • Theoretical and practical differences between the Gorlin formula and the continuity equation for calculating aortic and mitral valve areas
    • Dumesnil JG, Yoganathan AP. Theoretical and practical differences between the Gorlin formula and the continuity equation for calculating aortic and mitral valve areas. Am J Cardiol. 1991;67: 1268-1272.
    • (1991) Am J Cardiol , vol.67 , pp. 1268-1272
    • Dumesnil, J.G.1    Yoganathan, A.P.2
  • 42
    • 0021840799 scopus 로고
    • Hydraulic estimation of stenotic orifice area: A correction of the Gorlin formula
    • Cannon SR, Richards KL, Crawford M. Hydraulic estimation of stenotic orifice area: a correction of the Gorlin formula. Circulation. 1985;71:1170-1178.
    • (1985) Circulation , vol.71 , pp. 1170-1178
    • Cannon, S.R.1    Richards, K.L.2    Crawford, M.3
  • 43
    • 0011147065 scopus 로고
    • Non-invasive calculation of bioprosthetic valve orifice area
    • Bodnar E, ed. Proceedings of the 1989 Symposium. London, UK: ICR Publishers
    • Daboin NP, Frater RWN, Fisher U, Nanna M, Strom JA. Non-invasive calculation of bioprosthetic valve orifice area. In: Bodnar E, ed. Surgery for Heart Valve Disease. Proceedings of the 1989 Symposium. London, UK: ICR Publishers; 1990:57-64.
    • (1990) Surgery for Heart Valve Disease , pp. 57-64
    • Daboin, N.P.1    Frater, R.W.N.2    Fisher, U.3    Nanna, M.4    Strom, J.A.5
  • 44
    • 0021062242 scopus 로고
    • Three-dimensional reconstruction of the left ventricle from multiple cross sectional echo-cardiograms: Value for measuring left ventricular volume
    • Sawada H, Fujii J. Kato K, Onoe M, Kuno Y. Three-dimensional reconstruction of the left ventricle from multiple cross sectional echo-cardiograms: value for measuring left ventricular volume. Br Heart J. 1983;50:438-442.
    • (1983) Br Heart J , vol.50 , pp. 438-442
    • Sawada, H.1    Fujii, J.2    Kato, K.3    Onoe, M.4    Kuno, Y.5
  • 47
    • 0027363080 scopus 로고
    • Measurement of left ventricular volume by three-dimensional echocardiography: Present promise and potential problems
    • Pearlman AS. Measurement of left ventricular volume by three-dimensional echocardiography: present promise and potential problems. J Am Coll Cardiol. 1993;22:1538-1540.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1538-1540
    • Pearlman, A.S.1
  • 49
    • 9444290035 scopus 로고
    • Stenotic valve morphology influences measured pressure gradients and ventricular work for constant areas and flows
    • Abstract
    • Cape E, Kelly DL, Ettedgui JA, Park SC. Stenotic valve morphology influences measured pressure gradients and ventricular work for constant areas and flows. Circulation. 1992;86(suppl I):I-309. Abstract.
    • (1992) Circulation , vol.86 , Issue.1 SUPPL.
    • Cape, E.1    Kelly, D.L.2    Ettedgui, J.A.3    Park, S.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.