메뉴 건너뛰기




Volumn 131, Issue 5, 1996, Pages 961-965

Prospective randomized comparison of anodal monophasic shocks versus biphasic cathodal shocks on defibrillation energy requirements

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CLINICAL PROTOCOL; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DEFIBRILLATION; ELECTRIC SHOCK; ELECTRODE; ENERGY; FEMALE; HEART ARREST; HEART VENTRICLE FIBRILLATION; HUMAN; MALE; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; SINUS RHYTHM;

EID: 9244257270     PISSN: 00028703     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-8703(96)90180-5     Document Type: Article
Times cited : (8)

References (24)
  • 1
    • 0027374955 scopus 로고
    • Low-energy endocardial defibrillation using an axillary or a pectoral thoracic electrode location
    • Saksena S, DeGroot P, Krol, Raju R, Mathew P, Mehra R. Low-energy endocardial defibrillation using an axillary or a pectoral thoracic electrode location. Circulation 1993;88:2655-60.
    • (1993) Circulation , vol.88 , pp. 2655-2660
    • Saksena, S.1    DeGroot, P.2    Krol3    Raju, R.4    Mathew, P.5    Mehra, R.6
  • 3
    • 0028122160 scopus 로고
    • Implantation by electrophysiologists of 100 consecutive cardioverter defibrillators with non-thoracotomy lead systems
    • Strickberger SA, Hummel JD, Daoud E, Niebauer M, Williamson BD, Man KC, Horwood L. Implantation by electrophysiologists of 100 consecutive cardioverter defibrillators with non-thoracotomy lead systems. Circulation 1994;90:868-72.
    • (1994) Circulation , vol.90 , pp. 868-872
    • Strickberger, S.A.1    Hummel, J.D.2    Daoud, E.3    Niebauer, M.4    Williamson, B.D.5    Man, K.C.6    Horwood, L.7
  • 4
    • 0028197691 scopus 로고
    • Prospective, randomized comparison in humans of a unipolar defibrillation system with that using an additional superior vena cava electrode
    • Bardy GH, Dolack GL, Kudenchuk PJ, Poole JE, Mehra R, Johnson G. Prospective, randomized comparison in humans of a unipolar defibrillation system with that using an additional superior vena cava electrode. Circulation 1994;89:1090-3.
    • (1994) Circulation , vol.89 , pp. 1090-1093
    • Bardy, G.H.1    Dolack, G.L.2    Kudenchuk, P.J.3    Poole, J.E.4    Mehra, R.5    Johnson, G.6
  • 7
    • 0023792839 scopus 로고
    • Comparative efficacy of monophasic and biphasic truncated exponential shocks for nonthoracotomy internal defibrillation in dogs
    • Chapman PD, Vetter JW, Souza JJ, Troup PJ, Wetherbee JN, Hoffmann RG. Comparative efficacy of monophasic and biphasic truncated exponential shocks for nonthoracotomy internal defibrillation in dogs. J Am Coll Cardiol 1988;12:739-45.
    • (1988) J Am Coll Cardiol , vol.12 , pp. 739-745
    • Chapman, P.D.1    Vetter, J.W.2    Souza, J.J.3    Troup, P.J.4    Wetherbee, J.N.5    Hoffmann, R.G.6
  • 8
    • 0025696871 scopus 로고
    • Threshold reduction with biphasic defibrillator waveforms: Role of excitation channel recovery in a computer model of the ventricular action potential
    • Jones JL, Jones RE. Threshold reduction with biphasic defibrillator waveforms: role of excitation channel recovery in a computer model of the ventricular action potential. J Electrocardiol 1990;23:30-5.
    • (1990) J Electrocardiol , vol.23 , pp. 30-35
    • Jones, J.L.1    Jones, R.E.2
  • 9
    • 0024538635 scopus 로고
    • Improved internal defibrillation efficacy with a biphasic waveform
    • Fain ES, Sweeney MB, Franz MR. Improved internal defibrillation efficacy with a biphasic waveform. AM HEART J 1989;117:358-64.
    • (1989) Am Heart J , vol.117 , pp. 358-364
    • Fain, E.S.1    Sweeney, M.B.2    Franz, M.R.3
  • 11
    • 0024448644 scopus 로고
    • A prospective randomized evaluation of biphasic versus monophasic wave-form pulses on defibrillation efficacy in humans
    • Bardy GH, Ivey TD, Allen MD, Johnson G, Mehra R, Green HL. A prospective randomized evaluation of biphasic versus monophasic wave-form pulses on defibrillation efficacy in humans. J Am Coll Cardiol 1989;14:7288-33.
    • (1989) J Am Coll Cardiol , vol.14 , pp. 7288-7333
    • Bardy, G.H.1    Ivey, T.D.2    Allen, M.D.3    Johnson, G.4    Mehra, R.5    Green, H.L.6
  • 17
    • 0028136303 scopus 로고
    • Preliminary experience with a hybrid nonthoracotomy defibrillating system that includes a biphasic device: Comparison with a standard monophasic device using the same lead system
    • Natale A, Sra J, Axtell K, Maglio C, Dhala A, Deshpande S, Jazayeri M, Wase A, Akhtar M. Preliminary experience with a hybrid nonthoracotomy defibrillating system that includes a biphasic device: comparison with a standard monophasic device using the same lead system. J Am Coll Cardiol 1994;24:406-12.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 406-412
    • Natale, A.1    Sra, J.2    Axtell, K.3    Maglio, C.4    Dhala, A.5    Deshpande, S.6    Jazayeri, M.7    Wase, A.8    Akhtar, M.9
  • 18
    • 0028212031 scopus 로고
    • Electrode polarity is an important determinant of defibrillation efficacy using a nonthoracotomy system
    • Thakur RK, Souza JJ, Chapman PD, Troup PJ, Wetherbee JN. Electrode polarity is an important determinant of defibrillation efficacy using a nonthoracotomy system. PACE 1994;17:919-23.
    • (1994) PACE , vol.17 , pp. 919-923
    • Thakur, R.K.1    Souza, J.J.2    Chapman, P.D.3    Troup, P.J.4    Wetherbee, J.N.5
  • 19
    • 0027511198 scopus 로고
    • Transthoracic defibrillation: Effect of dual-pathway biphasic pulse shocks in a canine model
    • Scott BD, Kallok MJ, Birkett C, Kieso RA, Derber RE. Transthoracic defibrillation: effect of dual-pathway biphasic pulse shocks in a canine model. AM HEART J 1992;125:99-109.
    • (1992) Am Heart J , vol.125 , pp. 99-109
    • Scott, B.D.1    Kallok, M.J.2    Birkett, C.3    Kieso, R.A.4    Derber, R.E.5
  • 21
    • 0028210702 scopus 로고
    • Mechanisms of defibrillation for monophasic and biphasic waveforms
    • Walcott GP, Walcott KT, Knisley SB, Zhou X, Ideker RE. Mechanisms of defibrillation for monophasic and biphasic waveforms. PACE 1994; 17:400-570.
    • (1994) PACE , vol.17 , pp. 400-570
    • Walcott, G.P.1    Walcott, K.T.2    Knisley, S.B.3    Zhou, X.4    Ideker, R.E.5
  • 22
    • 0026877545 scopus 로고
    • Defibrillation threshold: Clinical utility and therapeutic implications
    • Singer I, Lang D. Defibrillation threshold: clinical utility and therapeutic implications. PACE 1992;15:932-49.
    • (1992) PACE , vol.15 , pp. 932-949
    • Singer, I.1    Lang, D.2
  • 23
    • 0004920245 scopus 로고
    • Implant support devices
    • Singer I, editor. Armond, NY: Futura Publishing Co, Inc
    • Lang DF, Ken Knight BH. Implant support devices. In Singer I, editor. Implantable cardioverter-defibrillator. Armond, NY: Futura Publishing Co, Inc, 1994:223.
    • (1994) Implantable Cardioverter-defibrillator , pp. 223
    • Lang, D.F.1    Ken Knight, B.H.2
  • 24
    • 0027469837 scopus 로고
    • Nonthoracotomy defibrillator lead systems: A welcomed addition but still a lot to learn
    • Marchlinski FE. Nonthoracotomy defibrillator lead systems: a welcomed addition but still a lot to learn. Circulation 1993;87:1410-1.
    • (1993) Circulation , vol.87 , pp. 1410-1411
    • Marchlinski, F.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.