Automated short-axis cardiac magnetic resonance image acquisitions: Accuracy of left ventricular dimension measurements in normal subjects and patients

Author keywords

Accuracy; Automated planning; Cardiovascular MRI; Global function; Left ventricle

Indexed keywords

ADULT; AGED; ARTICLE; AUTOMATION; CARDIOVASCULAR SYSTEM; CLINICAL ARTICLE; COMPUTER PROGRAM; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART LEFT VENTRICLE FUNCTION; HEART LEFT VENTRICLE MASS; HUMAN; IMAGE ANALYSIS; MEASUREMENT; NUCLEAR MAGNETIC RESONANCE IMAGING; PLANNING; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS;

EID: 9244247635     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004424-200412000-00006     Document Type: Article
Times cited : (7)

References (18)
  • 1
    • 0037561208 scopus 로고    scopus 로고
    • Comparison of cardiac MRI on 1.5 and 3.0 tesla clinical whole body systems
    • Hinton DP, Wald LL, Pitts JRTR, et al. Comparison of cardiac MRI on 1.5 and 3.0 tesla clinical whole body systems. Invest Radiol. 2003;38:436-442.
    • (2003) Invest Radiol , vol.38 , pp. 436-442
    • Hinton, D.P.1    Wald, L.L.2    Pitts, J.R.T.R.3
  • 2
    • 0036104746 scopus 로고    scopus 로고
    • Breath-hold FLASH and FISP cardiovascular MR imaging: Left ventricular volume differences and reproducibility
    • Moon JCC, Lorenz CH, Francis JM, et al. Breath-hold FLASH and FISP cardiovascular MR imaging: left ventricular volume differences and reproducibility. Radiology. 2002;223:789-797.
    • (2002) Radiology , vol.223 , pp. 789-797
    • Moon, J.C.C.1    Lorenz, C.H.2    Francis, J.M.3
  • 3
    • 0023031769 scopus 로고
    • Evaluation of left ventricular volumes measured by magnetic resonance imaging
    • Mogelvang J, Thomsen C, Mehlsen J, et al. Evaluation of left ventricular volumes measured by magnetic resonance imaging. Eur Heart J. 1986;7:1016-1021.
    • (1986) Eur Heart J , vol.7 , pp. 1016-1021
    • Mogelvang, J.1    Thomsen, C.2    Mehlsen, J.3
  • 4
    • 0033018548 scopus 로고    scopus 로고
    • Global left ventricular cardiac function: Comparison between magnetic resonance imaging, radionuclide angiography, and contrast angiography
    • Lethimonnier F, Furber A, Balzer P, et al. Global left ventricular cardiac function: comparison between magnetic resonance imaging, radionuclide angiography, and contrast angiography. Invest Radiol. 1999;34:199-203.
    • (1999) Invest Radiol , vol.34 , pp. 199-203
    • Lethimonnier, F.1    Furber, A.2    Balzer, P.3
  • 5
    • 0028927206 scopus 로고
    • Left ventricular quantification with breath hold MR imaging: Comparison with echocardiography
    • Bogaert JG, Bosnians HT, Rademakers FE, et al. Left ventricular quantification with breath hold MR imaging: comparison with echocardiography. MAGMA. 1995;3:5-12.
    • (1995) MAGMA , vol.3 , pp. 5-12
    • Bogaert, J.G.1    Bosnians, H.T.2    Rademakers, F.E.3
  • 6
    • 0036642629 scopus 로고    scopus 로고
    • Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy
    • Grothues F, Smith GC, Moon JCC, et al. Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. Am J Cardiol. 2002;90:29-34.
    • (2002) Am J Cardiol , vol.90 , pp. 29-34
    • Grothues, F.1    Smith, G.C.2    Moon, J.C.C.3
  • 7
    • 0023470709 scopus 로고
    • Oblique views in magnetic resonance imaging of the heart by combined axial rotation
    • van Rossum AC, Visser FC, van Eenige MJ, et al. Oblique views in magnetic resonance imaging of the heart by combined axial rotation. Acta Radiol. 1987;28:497-503.
    • (1987) Acta Radiol , vol.28 , pp. 497-503
    • Van Rossum, A.C.1    Visser, F.C.2    Van Eenige, M.J.3
  • 8
    • 0022643362 scopus 로고
    • Measurement of normal left heart dimensions using optimally oriented MR images
    • Kaul S, Wismer GL, Brady TJ, et al. Measurement of normal left heart dimensions using optimally oriented MR images. AJR Am J Roentgenol. 1986;146:75-79.
    • (1986) AJR Am J Roentgenol , vol.146 , pp. 75-79
    • Kaul, S.1    Wismer, G.L.2    Brady, T.J.3
  • 9
    • 0034761666 scopus 로고    scopus 로고
    • Automated Observer-independent acquisition of cardiac short axis MR images: A pilot study
    • Lelieveldt BPF, van der Geest RJ, Lamb HJ, et al. Automated Observer-independent acquisition of cardiac short axis MR images: a pilot study. Radiology. 2001;221:537-542.
    • (2001) Radiology , vol.221 , pp. 537-542
    • Lelieveldt, B.P.F.1    Van Der Geest, R.J.2    Lamb, H.J.3
  • 10
    • 0345686518 scopus 로고    scopus 로고
    • Automatic planning of the acquisition of cardiac MR images
    • Ellis RE, Peters TM, eds. Berlin: Springer;
    • Jackson C, Robson M, Francis J, et al. Automatic planning of the acquisition of cardiac MR images. In: Ellis RE, Peters TM, eds. Proc MICCAI LNCS 2878, vol 1. Berlin: Springer; 2003:541-548.
    • (2003) Proc MICCAI LNCS 2878 , vol.1 , pp. 541-548
    • Jackson, C.1    Robson, M.2    Francis, J.3
  • 11
    • 0032587715 scopus 로고    scopus 로고
    • Anatomical model matching with fuzzy implicit surfaces for segmentation of thoracic volume scans
    • Lelieveldt BPF, van der Geest RJ, Rezaee MR, et al. Anatomical model matching with fuzzy implicit surfaces for segmentation of thoracic volume scans. IEEE Trans Med Imaging. 1999;18:218-230.
    • (1999) IEEE Trans Med Imaging , vol.18 , pp. 218-230
    • Lelieveldt, B.P.F.1    Van Der Geest, R.J.2    Rezaee, M.R.3
  • 12
    • 0034298728 scopus 로고    scopus 로고
    • Anatomical modeling with fuzzy implicit surface templates: Application to automated localization of the heart and lungs in thoracic MR volumes
    • Lelieveldt BPF, Sonka M, Bolinger L, et al. Anatomical modeling with fuzzy implicit surface templates: application to automated localization of the heart and lungs in thoracic MR volumes. Comp Vis Img Understand. 2000;80:1-20.
    • (2000) Comp Vis Img Understand , vol.80 , pp. 1-20
    • Lelieveldt, B.P.F.1    Sonka, M.2    Bolinger, L.3
  • 13
    • 0027512694 scopus 로고
    • Left ventricular measurements with cine and spin-echo MR imaging: A study of reproducibility with variance component analysis
    • Pattynama PMT, Lamb HJ, van der Velde EA, et al. Left ventricular measurements with cine and spin-echo MR imaging: a study of reproducibility with variance component analysis. Radiology. 1993;187:261-268.
    • (1993) Radiology , vol.187 , pp. 261-268
    • Pattynama, P.M.T.1    Lamb, H.J.2    Van Der Velde, E.A.3
  • 14
    • 0030984423 scopus 로고    scopus 로고
    • Biventricular function in patients with nonischemic right ventricle tachyarrhythmias assessed with MR imaging
    • Kayser HW, Schalij MJ, van der Wall EE, et al. Biventricular function in patients with nonischemic right ventricle tachyarrhythmias assessed with MR imaging. AJR Am J Roentgenol. 1999;169:995-999.
    • (1999) AJR Am J Roentgenol , vol.169 , pp. 995-999
    • Kayser, H.W.1    Schalij, M.J.2    Van Der Wall, E.E.3
  • 15
    • 0033301605 scopus 로고    scopus 로고
    • Normal human right and left ventricular mass, systolic function, and gender differences by cine magnetic resonance imaging
    • Lorenz CH, Walker ES, Morgan VL, et al. Normal human right and left ventricular mass, systolic function, and gender differences by cine magnetic resonance imaging. J Cardiovasc Magn Reson. 1999;1:7-21.
    • (1999) J Cardiovasc Magn Reson , vol.1 , pp. 7-21
    • Lorenz, C.H.1    Walker, E.S.2    Morgan, V.L.3
  • 16
    • 0029944649 scopus 로고    scopus 로고
    • Assessment of left ventricular volume and mass by cine magnetic resonance imaging in patients with anterior myocardial infarction intra-observer and inter-observer variability on contour detection
    • Matheijssen NA, Baur LH, Reiber JH, et al. Assessment of left ventricular volume and mass by cine magnetic resonance imaging in patients with anterior myocardial infarction intra-observer and inter-observer variability on contour detection. Int J Card Imaging. 1996;12:11-19.
    • (1996) Int J Card Imaging , vol.12 , pp. 11-19
    • Matheijssen, N.A.1    Baur, L.H.2    Reiber, J.H.3
  • 17
    • 84908219488 scopus 로고
    • Statistical Methods for assessing agreement between two methods of clinical measuments
    • Bland JM, Altman DG. Statistical Methods for assessing agreement between two methods of clinical measuments. Lancet. 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 18
    • 9244226417 scopus 로고    scopus 로고
    • Automatic planning of short-axis MRI acquisition: Prospective validation study
    • Danilouchkine MG, Westenberg JJM, Lamb HJ, et al. Automatic planning of short-axis MRI acquisition: prospective validation study. J Cardiovasc Magn Reson. 2004;6:408-409.
    • (2004) J Cardiovasc Magn Reson , vol.6 , pp. 408-409
    • Danilouchkine, M.G.1    Westenberg, J.J.M.2    Lamb, H.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.