메뉴 건너뛰기




Volumn 354, Issue 2, 2004, Pages 91-94

Intracranial measurement of current densities induced by transcranial magnetic stimulation in the human brain

Author keywords

Depth electrode; Induced currents; Transcranial magnetic stimulation

Indexed keywords

ANTICONVULSIVE AGENT; ETIRACETAM; PHENYTOIN; TOPIRAMATE;

EID: 9144258079     PISSN: 03043940     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0304-3940(03)00861-9     Document Type: Article
Times cited : (66)

References (20)
  • 2
    • 0029144366 scopus 로고
    • An accurate 3-D model for magnetic stimulation of the brain cortex
    • Cerri G., De Leo R., Moglie F., Schiavoni A. An accurate 3-D model for magnetic stimulation of the brain cortex. J. Med. Eng. Technol. 19:1995;7-16.
    • (1995) J. Med. Eng. Technol. , vol.19 , pp. 7-16
    • Cerri, G.1    De Leo, R.2    Moglie, F.3    Schiavoni, A.4
  • 5
    • 0035280242 scopus 로고    scopus 로고
    • Sham TMS: Intracerebral measurement of the induced electrical field and the induction of motor-evoked potentials
    • Lisanby S., Gutman D., Luber B., Schroeder C., Sackeim H.A. Sham TMS: intracerebral measurement of the induced electrical field and the induction of motor-evoked potentials. Biol. Psychiatry. 49:2001;460-463.
    • (2001) Biol. Psychiatry , vol.49 , pp. 460-463
    • Lisanby, S.1    Gutman, D.2    Luber, B.3    Schroeder, C.4    Sackeim, H.A.5
  • 7
    • 0142089289 scopus 로고    scopus 로고
    • Simulation of the influence of tissue inhomogeneity on nerve excitation elicited by magnetic stimulation
    • H.K. Chang, Zhang Y.T. Hong Kong: IEEE
    • Liu R., Ueno S. Simulation of the influence of tissue inhomogeneity on nerve excitation elicited by magnetic stimulation. Chang H.K., Zhang Y.T. Proceedings of the 20th Annual International Conference of the IEEE Medicine and Biology Society. 6:1998;2998-3000 IEEE, Hong Kong.
    • (1998) Proceedings of the 20th Annual International Conference of the IEEE Medicine and Biology Society , vol.6 , pp. 2998-3000
    • Liu, R.1    Ueno, S.2
  • 8
    • 0025140622 scopus 로고
    • Spatial distribution of the electric field induced in volume by round and figure '8' magnetic coils: Relevance to activation of sensory nerve fibers
    • Maccabee P., Eberle L., Amassian V.E., Cracco R.Q., Rudell A., Jayachandra M. Spatial distribution of the electric field induced in volume by round and figure '8' magnetic coils: relevance to activation of sensory nerve fibers. Electroenceph. clin. Neurophysiol. 76:1990;131-141.
    • (1990) Electroenceph. Clin. Neurophysiol. , vol.76 , pp. 131-141
    • MacCabee, P.1    Eberle, L.2    Amassian, V.E.3    Cracco, R.Q.4    Rudell, A.5    Jayachandra, M.6
  • 9
    • 0026525873 scopus 로고
    • The heating of metal electrodes during rapid-rate magnetic stimulation: A possible safety hazard
    • Roth B.J., Pascual-Leone A., Cohen L.G., Hallett M. The heating of metal electrodes during rapid-rate magnetic stimulation: a possible safety hazard. Electroenceph. clin. Neurophysiol. 85:1992;116-123.
    • (1992) Electroenceph. Clin. Neurophysiol. , vol.85 , pp. 116-123
    • Roth, B.J.1    Pascual-Leone, A.2    Cohen, L.G.3    Hallett, M.4
  • 10
    • 0025845766 scopus 로고
    • A theoretical calculation of the electric field induced in the cortex during magnetic stimulation
    • Roth B.J., Saypol J.M., Hallett M., Cohen L.G. A theoretical calculation of the electric field induced in the cortex during magnetic stimulation. Electroenceph. clin. Neurophysiol. 81:1991;47-56.
    • (1991) Electroenceph. Clin. Neurophysiol. , vol.81 , pp. 47-56
    • Roth, B.J.1    Saypol, J.M.2    Hallett, M.3    Cohen, L.G.4
  • 11
    • 0032712328 scopus 로고    scopus 로고
    • Safety of single and repetitive focal transcranial magnetic stimuli as assessed by intracranial EEG recordings in patients with partial epilepsy
    • Schulze-Bonhage A., Scheufler K., Zentner J., Elger C.E. Safety of single and repetitive focal transcranial magnetic stimuli as assessed by intracranial EEG recordings in patients with partial epilepsy. J. Neurol. 246:1999;914-919.
    • (1999) J. Neurol. , vol.246 , pp. 914-919
    • Schulze-Bonhage, A.1    Scheufler, K.2    Zentner, J.3    Elger, C.E.4
  • 16
    • 0031930002 scopus 로고    scopus 로고
    • Risk and safety of repetitive transcranial magnetic stimulation: Report and suggested guidelines from the International Workshop on the Safety of Repetitive Transcranial Magnetic Stimulation, June 5-7, 1996
    • Wassermann E.M. Risk and safety of repetitive transcranial magnetic stimulation: report and suggested guidelines from the International Workshop on the Safety of Repetitive Transcranial Magnetic Stimulation, June 5-7, 1996. Electroenceph. clin. Neurophysiol. 108:1998;1-16.
    • (1998) Electroenceph. Clin. Neurophysiol. , vol.108 , pp. 1-16
    • Wassermann, E.M.1
  • 17
    • 0033895730 scopus 로고    scopus 로고
    • Motor cortex excitability in patients with focal epilepsy
    • Werhahn K.J., Lieber J., Classen J., Noachtar S. Motor cortex excitability in patients with focal epilepsy. Epilepsy Res. 41:2000;179-189.
    • (2000) Epilepsy Res. , vol.41 , pp. 179-189
    • Werhahn, K.J.1    Lieber, J.2    Classen, J.3    Noachtar, S.4
  • 18
    • 0025967887 scopus 로고
    • Developing a more focal magnetic stimulator. Part 2: Fabricating coils and measuring induced current distributions
    • Yunokuchi K., Cohen D. Developing a more focal magnetic stimulator. part 2: fabricating coils and measuring induced current distributions. J. Clin. Neurophys. 8:1991;112-120.
    • (1991) J. Clin. Neurophys. , vol.8 , pp. 112-120
    • Yunokuchi, K.1    Cohen, D.2
  • 20
    • 0031937558 scopus 로고    scopus 로고
    • Transcranial magnetic stimulation: Its current role in epilepsy research
    • Ziemann U., Steinhoff B.J., Tergau F., Paulus W. Transcranial magnetic stimulation: its current role in epilepsy research. Epilepsy Res. 30:1998;11-30.
    • (1998) Epilepsy Res. , vol.30 , pp. 11-30
    • Ziemann, U.1    Steinhoff, B.J.2    Tergau, F.3    Paulus, W.4