메뉴 건너뛰기




Volumn 11, Issue 5, 2004, Pages 870-880

Electrical performance of ice-covered insulators at high altitudes

Author keywords

Atmospheric ice; Flashover; Low pressure; Outdoor insulation; Pollution

Indexed keywords

ATMOSPHERICS; CURRENT DENSITY; ELECTRIC INSULATION; ELECTRIC POTENTIAL; FLASHOVER; MATHEMATICAL MODELS; PERFORMANCE; POLLUTION; PRESSURE EFFECTS;

EID: 9144224426     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2004.1349793     Document Type: Conference Paper
Times cited : (30)

References (31)
  • 1
    • 0027629159 scopus 로고
    • Long range transported pollution and conductivity on atmospheric ice on insulators
    • S. M. Fikke, J. E. Hanssen and L. Rolfseng, "Long Range Transported Pollution and Conductivity on Atmospheric Ice on Insulators", IEEE Trans. Power Del., Vol. 8, pp. 1311-1321, 1993.
    • (1993) IEEE Trans. Power Del. , vol.8 , pp. 1311-1321
    • Fikke, S.M.1    Hanssen, J.E.2    Rolfseng, L.3
  • 2
    • 0006672875 scopus 로고
    • The influence of snow and ice deposits on supertension transmission line insulator strings with special reference to high altitude operation
    • London, England
    • A. Meier and W. M. Niggli, "The Influence of Snow and Ice Deposits on Supertension Transmission Line Insulator Strings with Special Reference to High Altitude Operation", IEEE Conf. Publ. 44, London, England, pp. 386-395, 1968.
    • (1968) IEEE Conf. Publ. 44 , pp. 386-395
    • Meier, A.1    Niggli, W.M.2
  • 6
    • 0020950943 scopus 로고
    • Minimum flashover voltage of iced insulators
    • C. Phan and H. Matsuo, "Minimum Flashover Voltage of Iced Insulators", IEEE Trans. Electr. Insul., Vol. 18, pp. 605-618, 1983.
    • (1983) IEEE Trans. Electr. Insul. , vol.18 , pp. 605-618
    • Phan, C.1    Matsuo, H.2
  • 7
    • 0026191180 scopus 로고
    • Withstand voltage characteristics of insulator strings covered with snow or ice
    • H. Matsuda, H. Komuro and K. Takasu, "Withstand Voltage Characteristics of Insulator Strings Covered with Snow or Ice", IEEE Trans. Power Del., Vol. 6, pp. 1243-1250, 1991.
    • (1991) IEEE Trans. Power Del. , vol.6 , pp. 1243-1250
    • Matsuda, H.1    Komuro, H.2    Takasu, K.3
  • 9
    • 0031258323 scopus 로고    scopus 로고
    • Flashover performance of IEEE standard insulators under ice conditions
    • M. Farzaneh and J. Kiernicki, "Flashover Performance of IEEE Standard Insulators Under Ice Conditions", IEEE Trans. on Power Delivery, Vol. 12, pp. 1602-1613, 1997.
    • (1997) IEEE Trans. on Power Delivery , vol.12 , pp. 1602-1613
    • Farzaneh, M.1    Kiernicki, J.2
  • 10
    • 0006631063 scopus 로고
    • Review of the effect of pollution on high-voltage insulators and metal-oxide arresters
    • Austria, Paper
    • F. A. M. Rizk, "Review of the Effect of Pollution on High-Voltage Insulators and Metal-Oxide Arresters", Proc. 9th Intern. Sympos. HV Engineering (ISH), Austria, Paper 9003, 1995.
    • (1995) Proc. 9th Intern. Sympos. HV Engineering (ISH) , pp. 9003
    • Rizk, F.A.M.1
  • 12
    • 0024479565 scopus 로고
    • Influence of low air pressure on flashover voltages of polluted insulators: Test data, generalization attempts and some recommendations
    • V. M. Rudakova and N. N. Tikhodeev, "Influence of Low Air Pressure on Flashover Voltages of Polluted Insulators: Test Data, Generalization Attempts and Some Recommendations", IEEE Trans. Power Del., Vol. 4, pp. 607-613, 1989.
    • (1989) IEEE Trans. Power Del. , vol.4 , pp. 607-613
    • Rudakova, V.M.1    Tikhodeev, N.N.2
  • 13
    • 0028749324 scopus 로고
    • Discharge performance of different models at low pressure air
    • Z. Guan and C. Huang, "Discharge Performance of Different Models at Low Pressure Air", Proc. 4th ICPADM, Brisbane, Australia, pp. 463-466, 1994.
    • (1994) Proc. 4th ICPADM, Brisbane, Australia , pp. 463-466
    • Guan, Z.1    Huang, C.2
  • 14
    • 0020087881 scopus 로고
    • Pressure dependence of DC breakdown of contaminated insulators
    • T. Kawamura, M. Ishii, M. Akbar and K. Nagai, "Pressure Dependence of DC Breakdown of Contaminated Insulators", IEEE Trans. Electr. Insul., Vol. 17, pp. 39-45, 1982.
    • (1982) IEEE Trans. Electr. Insul. , vol.17 , pp. 39-45
    • Kawamura, T.1    Ishii, M.2    Akbar, M.3    Nagai, K.4
  • 16
    • 85013578909 scopus 로고    scopus 로고
    • Critical flashover voltage of short HV insulator covered with ice at low atmospheric pressure
    • Beijing, China
    • Y. Li, M. Farzaneh and J. Zhang, "Critical Flashover Voltage of Short HV Insulator Covered with Ice at Low Atmospheric Pressure", Proc. Intern. Conf. Power Syst. Techn. (POWERCON 1998), Beijing, China, Vol. 1, pp. 520-523, 1998.
    • (1998) Proc. Intern. Conf. Power Syst. Techn. (POWERCON 1998) , vol.1 , pp. 520-523
    • Li, Y.1    Farzaneh, M.2    Zhang, J.3
  • 20
    • 0035181666 scopus 로고    scopus 로고
    • AC flashover performance of polluted insulators covered with artificial ice at low atmospheric pressure
    • Kitchener, Canada
    • L. Shu, M. Farzaneh, Y. Li and W. Sima, "AC Flashover Performance of Polluted Insulators Covered with Artificial Ice at Low Atmospheric Pressure", IEEE Conf. Electr. Insul. Dielectric Phenomena (CEIDP), Kitchener, Canada, pp. 609-612, 2001.
    • (2001) IEEE Conf. Electr. Insul. Dielectric Phenomena (CEIDP) , pp. 609-612
    • Shu, L.1    Farzaneh, M.2    Li, Y.3    Sima, W.4
  • 21
    • 9144250998 scopus 로고    scopus 로고
    • Correction of flashover characteristics of insulators in special environment
    • Bangalore, India, Paper 5-35
    • L. Shu, W. Sima, C. Sun and L. Gu, "Correction of Flashover Characteristics of Insulators in Special Environment", Proc. 12th Intern. Sympos. HV Eng. (ISH 2001), Bangalore, India, Vol. 3, Paper 5-35, 2001.
    • (2001) Proc. 12th Intern. Sympos. HV Eng. (ISH 2001) , vol.3
    • Shu, L.1    Sima, W.2    Sun, C.3    Gu, L.4
  • 22
    • 0347933364 scopus 로고    scopus 로고
    • Ice accretions on high-voltage conductors and insulators and related phenomena
    • M. Farzaneh, "Ice Accretions on High-Voltage Conductors and Insulators and Related Phenomena", Phil. Trans. Roy. Soc., Vol. 358, No. 1776, pp. 297-3005, 2000.
    • (2000) Phil. Trans. Roy. Soc. , vol.358 , Issue.1776 , pp. 297-3005
    • Farzaneh, M.1
  • 23
    • 0003173666 scopus 로고    scopus 로고
    • Influence of ice and snow on the flashover performance of outdoor insulators, part I: Effects of Ice
    • CIGRE Task Force 33.04.09, "Influence of Ice and Snow on the Flashover Performance of Outdoor Insulators, Part I: Effects of Ice", ÉLECTRA No, 187, pp. 90-111, 1999.
    • (1999) ÉLECTRA No , vol.187 , pp. 90-111
  • 25
    • 0030733755 scopus 로고    scopus 로고
    • Modeling of the AC arc discharge on ice surfaces
    • M. Farzaneh, J. Zhang and X. Chen, "Modeling of the AC Arc Discharge on Ice Surfaces", IEEE Trans. Power Del., Vol. 12, pp. 325-338, 1997.
    • (1997) IEEE Trans. Power Del. , vol.12 , pp. 325-338
    • Farzaneh, M.1    Zhang, J.2    Chen, X.3
  • 26
    • 80052707129 scopus 로고    scopus 로고
    • Computation of AC critical flashover voltage of insulators covered with ice
    • Beijing, China
    • J. Zhang and M. Farzaneh, "Computation of AC Critical Flashover Voltage of Insulators Covered with Ice", Proc. Intern. Conf. Power Syst. Techn. (POWERCON 1998), Beijing, China, Vol. 1, pp. 524-528, 1998.
    • (1998) Proc. Intern. Conf. Power Syst. Techn. (POWERCON 1998) , vol.1 , pp. 524-528
    • Zhang, J.1    Farzaneh, M.2
  • 27
    • 77951521774 scopus 로고
    • Artificial pollution tests on high-voltage insulators to be used on A.C. systems
    • International Electrotechnical Commission (IEC), "Artificial Pollution Tests on High-voltage Insulators to be Used on A.C. Systems", International Standard 507, 1991.
    • (1991) International Standard , vol.507
  • 28
    • 34250904222 scopus 로고
    • Insulator pollution performance at high altitude: Major trends
    • H. P. Mercure, "Insulator Pollution Performance at High Altitude: Major Trends", IEEE Trans. Power Del., Vol. 4, pp. 1461-1468, 1989.
    • (1989) IEEE Trans. Power Del. , vol.4 , pp. 1461-1468
    • Mercure, H.P.1
  • 30
    • 9144245561 scopus 로고
    • Influence of air pressure on AC flashover voltage of polluted post insulators for high altitude regions
    • Japan, Paper No. 46.01
    • C. Huang, Z. Guan and R. Zhang, "Influence of Air Pressure on AC Flashover Voltage of Polluted Post Insulators for High Altitude Regions", Proc. 8th Intern. Sympos. HV Eng. (ISH), Japan, Paper No. 46.01, 1993.
    • (1993) Proc. 8th Intern. Sympos. HV Eng. (ISH)
    • Huang, C.1    Guan, Z.2    Zhang, R.3
  • 31
    • 0006671749 scopus 로고    scopus 로고
    • Modeling of altitude effects on AC flashover of polluted high voltage insulators
    • Paper 96 WM 104-0 PWRD
    • F. A. M. Rizk and A. Q. Rezazada, "Modeling of Altitude Effects on AC Flashover of Polluted High Voltage Insulators", IEEE, PES Winter Meeting, Paper 96 WM 104-0 PWRD, 1996.
    • (1996) IEEE, PES Winter Meeting
    • Rizk, F.A.M.1    Rezazada, A.Q.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.