Volumn 28, Issue 2, 1996, Pages 71-78

Significant safety advantages gained with an improved pressure-regulated blood pump

Author keywords

cardiopulmonary bypass; centrifugal pump; non occlusive pump; roller pump; safety

Indexed keywords

ARTICLE; BLOOD PRESSURE REGULATION; BLOOD PUMP; CARDIOPULMONARY BYPASS; OXYGENATOR; RISK ASSESSMENT; TECHNICAL AID; TECHNOLOGY;

EID: 8944220718     PISSN: 00221058     EISSN: 29698960     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (23)

References (7)
  • 2
    • 0025015683 scopus 로고
    • Beware centrifugal pumps: Not a one-way street, but a potentially dangerous "siphon"
    • Kolff J, McClurken JB, Alpern JB. Beware centrifugal pumps: Not a one-way street, but a potentially dangerous "siphon." [letter] Ann Thorac Surg. 1990;50(3):512.
    • (1990) Ann Thorac Surg. , vol.50 , Issue.3 , pp. 512
    • Kolff, J.1    McClurken, J.B.2    Alpern, J.B.3
  • 3
    • 85160894418 scopus 로고
    • Sarns Delphin II centrifugal system, Technical Compendium
    • Ann Arbor, MI.
    • Sarns Delphin II centrifugal system, Technical Compendium. Sarns 3M Health Care. 1993; Ann Arbor, MI.
    • (1993) Sarns 3M Health Care
  • 4
    • 85160881025 scopus 로고
    • Medtronic Bio-Medicus Presents More than Just a Pump
    • Eden Prairie, MN
    • Medtronic Bio-Medicus Presents More than Just a Pump, Medtronic Bio-Medicus. 1991; Eden Prairie, MN
    • (1991) Medtronic Bio-Medicus
  • 5
    • 2442754795 scopus 로고
    • A comparison of three centrifugal pumps' ability to expel micro-air under conditions of cavitation or bolus air injection
    • Ann Arbor, MI
    • Pacheco DA, Ingram JM, Pacheco SL. A comparison of three centrifugal pumps' ability to expel micro-air under conditions of cavitation or bolus air injection. Sarns 3M Health Care. 1993; Ann Arbor, MI.
    • (1993) Sarns 3M Health Care
    • Pacheco, D.A.1    Ingram, J.M.2    Pacheco, S.L.3
  • 6
    • 0026611253 scopus 로고
    • Tubing spallation in extracorporeal circuits. An in vitro study using an electronic particle counter
    • Briceño, JC, Runge TM. Tubing spallation in extracorporeal circuits. An in vitro study using an electronic particle counter. Int J Artif Organs. 1992; 15(4):222-228.
    • (1992) Int J Artif Organs , vol.15 , Issue.4 , pp. 222-228
    • Briceño, J.C.1    Runge, T.M.2
  • 7
    • 0027732923 scopus 로고
    • The effects of pressure and flow on hemolysis caused by Bio-Medicus centrifugal pumps and roller pumps
    • Tamari Y, Lee-Sensiba K, Leonard EF. The effects of pressure and flow on hemolysis caused by Bio-Medicus centrifugal pumps and roller pumps. J Thorac Cardiovasc Surg. 1993;106(6):997-1007
    • (1993) J Thorac Cardiovasc Surg. , vol.106 , Issue.6 , pp. 997-1007
    • Tamari, Y.1    Lee-Sensiba, K.2    Leonard, E.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.