메뉴 건너뛰기




Volumn 118, Issue 10, 2004, Pages 764-770

Navigation as a quality management tool in cochlear implant surgery

Author keywords

Cochlear implants; Reproducibility of Results; Surgery, Computer Assisted

Indexed keywords

ARTICLE; CADAVER; COCHLEA PROSTHESIS; COCHLEOSTOMY; COMPUTER ASSISTED SURGERY; EAR SURGERY; HUMAN; IMPLANTATION; MASTOIDECTOMY; MYRINGOTOMY; REPRODUCIBILITY; SURGICAL TECHNIQUE;

EID: 8844232696     PISSN: 00222151     EISSN: None     Source Type: Journal    
DOI: 10.1258/0022215042450643     Document Type: Article
Times cited : (72)

References (26)
  • 2
    • 0023860273 scopus 로고
    • Use of multichannel cochlear implants in obstructed and obliterated cochleas
    • Gantz BJ, McCabe BF, Tyler RS. Use of multichannel cochlear implants in obstructed and obliterated cochleas. Otolaryngol Head Neck Surg 1988;98:72-81
    • (1988) Otolaryngol Head Neck Surg , vol.98 , pp. 72-81
    • Gantz, B.J.1    McCabe, B.F.2    Tyler, R.S.3
  • 3
    • 0033071410 scopus 로고    scopus 로고
    • Extended indications for cochlear implantation. The Freiburg results in patients with residual hearing
    • Klenzner T, Stecker M, Marangos N, Laszig R. Extended indications for cochlear implantation. The Freiburg results in patients with residual hearing [in German]. HNO 1999;47:95-100
    • (1999) HNO , vol.47 , pp. 95-100
    • Klenzner, T.1    Stecker, M.2    Marangos, N.3    Laszig, R.4
  • 4
    • 0031659781 scopus 로고    scopus 로고
    • Cochlear Implant for adults obtaining marginal benefit from acoustic amplification: A European study
    • Fraysse B, Dillier N, Klenzner T, Laszig R, Manrique M, Ferez CM, et al. Cochlear Implant for adults obtaining marginal benefit from acoustic amplification: a European study. Am J Otol 1998;19:591-7
    • (1998) Am J Otol , vol.19 , pp. 591-597
    • Fraysse, B.1    Dillier, N.2    Klenzner, T.3    Laszig, R.4    Manrique, M.5    Ferez, C.M.6
  • 5
    • 0027248538 scopus 로고
    • Intracochlear placement of cochlear implant electrodes in soft surgery technique
    • Lehnhardt E. Intracochlear placement of cochlear implant electrodes in soft surgery technique [in German]. HNO 1993;41:356-9
    • (1993) HNO , vol.41 , pp. 356-359
    • Lehnhardt, E.1
  • 6
    • 0036237675 scopus 로고    scopus 로고
    • Intracochlear insertion of electrodes using hyaluronic acid in cochlear implant surgery
    • Laszig R, Ridder GJ, Fradis M. Intracochlear insertion of electrodes using hyaluronic acid in cochlear implant surgery. J Laryngol Otol 2002;116:371-2
    • (2002) J Laryngol Otol , vol.116 , pp. 371-372
    • Laszig, R.1    Ridder, G.J.2    Fradis, M.3
  • 7
    • 0036139998 scopus 로고    scopus 로고
    • Ultracision: An alternative to electrocautery in revision cochlear implant surgery
    • Laszig R, Ridder GJ, Aschendorff A, Fradis M. Ultracision: An alternative to electrocautery in revision cochlear implant surgery. Laryngoscope 2002;112:190-1
    • (2002) Laryngoscope , vol.112 , pp. 190-191
    • Laszig, R.1    Ridder, G.J.2    Aschendorff, A.3    Fradis, M.4
  • 9
    • 0035061366 scopus 로고    scopus 로고
    • Suprameatal approach: New surgical approach for cochlear implantation
    • Kronenberg J, Migirov L, Dagan T. Suprameatal approach: new surgical approach for cochlear implantation. J Laryngol Otol 2001;115:283-5
    • (2001) J Laryngol Otol , vol.115 , pp. 283-285
    • Kronenberg, J.1    Migirov, L.2    Dagan, T.3
  • 10
    • 0031660728 scopus 로고    scopus 로고
    • Distances between the cochlea and adjacent structures related to cochlear implant surgery
    • Wysocki J. Distances between the cochlea and adjacent structures related to cochlear implant surgery. Surg Radiol Anat 1998;20:267-71
    • (1998) Surg Radiol Anat , vol.20 , pp. 267-271
    • Wysocki, J.1
  • 11
    • 0032782409 scopus 로고    scopus 로고
    • Dimensions of the human vestibular and tympanic scalae
    • Wysocki J. Dimensions of the human vestibular and tympanic scalae. Hearing Res 1999;135:39-46
    • (1999) Hearing Res , vol.135 , pp. 39-46
    • Wysocki, J.1
  • 12
    • 0033383613 scopus 로고    scopus 로고
    • Cochlear hook anatomy: Evaluation of the spatial relationship of the basal cochlear duct to middle ear landmarks
    • Stidham KR, Roberson JB. Cochlear hook anatomy: evaluation of the spatial relationship of the basal cochlear duct to middle ear landmarks. Acta Otolaryngol 1999;119:773-7
    • (1999) Acta Otolaryngol , vol.119 , pp. 773-777
    • Stidham, K.R.1    Roberson, J.B.2
  • 13
    • 0001557304 scopus 로고
    • Prosthèse auditive par excitation électrique àdistance du nerf sensorial a l'aide d'un bobinage inclus à demeure
    • Djourno A, Eyries C. Prosthèse auditive par excitation électrique àdistance du nerf sensorial a l'aide d'un bobinage inclus à demeure. Presse Med 1957;35:14-7
    • (1957) Presse Med , vol.35 , pp. 14-17
    • Djourno, A.1    Eyries, C.2
  • 14
    • 0017155242 scopus 로고
    • Cochlear implants
    • House WF. Cochlear implants. Ann Otol Rhinol Laryngol 1976;85(suppl 27):1-93
    • (1976) Ann Otol Rhinol Laryngol , vol.85 , Issue.SUPPL. 27 , pp. 1-93
    • House, W.F.1
  • 15
    • 0015023323 scopus 로고
    • Electrical stimulation of the human cochlea
    • Michelson RP. Electrical stimulation of the human cochlea. Arch Otolaryngol 1971;93:317-23
    • (1971) Arch Otolaryngol , vol.93 , pp. 317-323
    • Michelson, R.P.1
  • 16
    • 0013933109 scopus 로고
    • Electrical stimulation of the auditory nerve in man
    • Simmons FB. Electrical stimulation of the auditory nerve in man. Arch Otolaryngol 1966;84:24-76
    • (1966) Arch Otolaryngol , vol.84 , pp. 24-76
    • Simmons, F.B.1
  • 17
    • 0034992268 scopus 로고    scopus 로고
    • Adult cochlear implantation: The Birmingham and United Kingdom experiences
    • Proops DW. Adult cochlear implantation: the Birmingham and United Kingdom experiences. Otolaryngol Clin North Am 2001;34:447-53
    • (2001) Otolaryngol Clin North Am , vol.34 , pp. 447-453
    • Proops, D.W.1
  • 18
    • 0035990161 scopus 로고    scopus 로고
    • Modiolar proximity of three perimodiolar cochlear implant electrodes
    • Balkany TJ, Eshraghi AA, Yang N. Modiolar proximity of three perimodiolar cochlear implant electrodes. Acta Otolaryngol 2002;122:363-9
    • (2002) Acta Otolaryngol , vol.122 , pp. 363-369
    • Balkany, T.J.1    Eshraghi, A.A.2    Yang, N.3
  • 19
    • 0030638998 scopus 로고    scopus 로고
    • Dimensions of the temporal bone in small children in relation to the cochlear implant - An analysis of CT scans
    • Mack KF, Müller J, Helms J. Dimensions of the temporal bone in small children in relation to the cochlear implant - an analysis of CT scans. Adv Otorhinolaryngol 1997;52:57-9
    • (1997) Adv Otorhinolaryngol , vol.52 , pp. 57-59
    • Mack, K.F.1    Müller, J.2    Helms, J.3
  • 23
    • 0036948175 scopus 로고    scopus 로고
    • Meningitis following cochlear implantation: Pathomechanisms, clinical symptoms, conservative and surgical treatments
    • Arnold W, Bredberg G, Gstöttner W, Helms J, Hildmann H, Kiratzidis T, et al. Meningitis following cochlear implantation: pathomechanisms, clinical symptoms, conservative and surgical treatments. ORL 2002;64:382-3
    • (2002) ORL , vol.64 , pp. 382-383
    • Arnold, W.1    Bredberg, G.2    Gstöttner, W.3    Helms, J.4    Hildmann, H.5    Kiratzidis, T.6
  • 25
    • 0027946413 scopus 로고
    • Cochlear implantation in children: Labyrinthitis following pneumococcal otitis media in unimplanted and implanted cat cochleas
    • Dahm MC, Clark GM, Franz BK, Shepherd RK, Burton MJ, Robins-Browne R. Cochlear implantation in children: labyrinthitis following pneumococcal otitis media in unimplanted and implanted cat cochleas. Acta Otolaryngol 1994;114:620-5
    • (1994) Acta Otolaryngol , vol.114 , pp. 620-625
    • Dahm, M.C.1    Clark, G.M.2    Franz, B.K.3    Shepherd, R.K.4    Burton, M.J.5    Robins-Browne, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.