메뉴 건너뛰기




Volumn 3, Issue , 2004, Pages 2268-2277

Closed-loop control in clinical pharmacology: Paradigms, benefits, and challenges

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; HEALTH CARE; LYAPUNOV METHODS; MATHEMATICAL MODELS; PHARMACODYNAMICS; PROBLEM SOLVING; ROBUSTNESS (CONTROL SYSTEMS); SYSTEM STABILITY;

EID: 8744283560     PISSN: 07431619     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.23919/acc.2004.1383800     Document Type: Conference Paper
Times cited : (9)

References (52)
  • 4
    • 0032714110 scopus 로고    scopus 로고
    • Ketamine distribution described by a recirculatory pharmacokinetic model is not stereo-selective
    • T. K. Henthom, T. C. Krejcie, C. U. Niemann, C. Enders-Klein, C. A. Shanks, and M. J. Avram, "Ketamine distribution described by a recirculatory pharmacokinetic model is not stereo-selective," Anesthesiology, vol. 91, pp. 1733-1743, 1999.
    • (1999) Anesthesiology , vol.91 , pp. 1733-1743
    • Henthom, T.K.1    Krejcie, T.C.2    Niemann, C.U.3    Enders-Klein, C.4    Shanks, C.A.5    Avram, M.J.6
  • 5
    • 0019509593 scopus 로고
    • A general method for calculating the dosage scheme in linear pharmacokinetics
    • H. Schwilden, "A general method for calculating the dosage scheme in linear pharmacokinetics," Eur. J. Clin. Pharmacol., vol. 20, no. 5, pp. 379-386, 1981.
    • (1981) Eur. J. Clin. Pharmacol. , vol.20 , Issue.5 , pp. 379-386
    • Schwilden, H.1
  • 7
    • 0019818766 scopus 로고
    • Evaluation of methods for estimating population pharmacokinetic parameters II. Biexponential model and experimental pharmacokinetic data
    • L. B. Sheiner and S. L. Beal, "Evaluation of methods for estimating population pharmacokinetic parameters II. Biexponential model and experimental pharmacokinetic data," J. Pharmacokinetics Biopharm., vol. 9, no. 5, pp. 635-651, 1981.
    • (1981) J. Pharmacokinetics Biopharm. , vol.9 , Issue.5 , pp. 635-651
    • Sheiner, L.B.1    Beal, S.L.2
  • 8
    • 0021269554 scopus 로고
    • The population approach to pharmacokinetic data analysis: Rationale and standard data analysis methods
    • L. B. Sheiner, "The population approach to pharmacokinetic data analysis: Rationale and standard data analysis methods," Drug Metabolism Reviews, vol. 15, no. 1-2, pp. 153-171, 1984.
    • (1984) Drug Metabolism Reviews , vol.15 , Issue.1-2 , pp. 153-171
    • Sheiner, L.B.1
  • 9
    • 0003043542 scopus 로고
    • The possible effects of the aggregation of the molecules of haemoglobin on its dissociation curves
    • A. V. Hill, "The possible effects of the aggregation of the molecules of haemoglobin on its dissociation curves," J. Physiol., vol. 40, pp. iv-vii, 1910.
    • (1910) J. Physiol. , vol.40
    • Hill, A.V.1
  • 10
    • 0034111171 scopus 로고    scopus 로고
    • The reliability of pharmacodynatnic analysis by logistic regression: A computer simulation study
    • W. Lu and J. M. Bailey, "The reliability of pharmacodynatnic analysis by logistic regression: A computer simulation study," Anesthesiology, vol. 92, pp. 985-992, 2000.
    • (2000) Anesthesiology , vol.92 , pp. 985-992
    • Lu, W.1    Bailey, J.M.2
  • 11
    • 0344943246 scopus 로고    scopus 로고
    • Reliability of pharmacodynamic analysis by logistic regression: Mixed-effects modeling
    • to appear
    • W. Lu, J. G. Ramsay, and J. M. Bailey, "Reliability of pharmacodynamic analysis by logistic regression: Mixed-effects modeling," Anesthesiology, to appear.
    • Anesthesiology
    • Lu, W.1    Ramsay, J.G.2    Bailey, J.M.3
  • 12
    • 0021810482 scopus 로고
    • Computer-assisted continuous infusions of fentanyl during cardiac anesthesia: Comparison with a manual method
    • J. M. Alvis, J. G. Reves, A. V. Govier, P. G. Menkhaus, C. E. Henling, J. A. Spain, and E. Bradley, "Computer-assisted continuous infusions of fentanyl during cardiac anesthesia: Comparison with a manual method," Anesthesiology, vol. 63, pp. 41-49, 1985.
    • (1985) Anesthesiology , vol.63 , pp. 41-49
    • Alvis, J.M.1    Reves, J.G.2    Govier, A.V.3    Menkhaus, P.G.4    Henling, C.E.5    Spain, J.A.6    Bradley, E.7
  • 13
    • 0025646435 scopus 로고
    • Pharmacokinetics of fentanyl administered by computer-controlled infusion pump
    • S. L. Shafer, J. R. Varvel, N. Aziz, and J. C. Scott, "Pharmacokinetics of fentanyl administered by computer-controlled infusion pump," Anesthesiology, vol. 73, pp. 1092-1102, 1990.
    • (1990) Anesthesiology , vol.73 , pp. 1092-1102
    • Shafer, S.L.1    Varvel, J.R.2    Aziz, N.3    Scott, J.C.4
  • 14
    • 0026174235 scopus 로고
    • A simple analytical solution to the three compartment pharmacokinetic model suitable for computer controlled infusion pumps
    • J. M. Bailey and S. L. Shafer, "A simple analytical solution to the three compartment pharmacokinetic model suitable for computer controlled infusion pumps," IEEE Trans. Biomed. Eng., vol. 38, no. 6, pp. 522-525, 1991.
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , Issue.6 , pp. 522-525
    • Bailey, J.M.1    Shafer, S.L.2
  • 15
    • 0026752822 scopus 로고
    • Algorithms to rapidly achieve and maintain stable drug concentrations at the site of drug effect with a computer-controlled infusion
    • S. L. Shafer and K. Gregg, "Algorithms to rapidly achieve and maintain stable drug concentrations at the site of drug effect with a computer-controlled infusion," J. Pharmacokinetics Biopharm., vol. 20, no. 2, pp. 147-169, 1992.
    • (1992) J. Pharmacokinetics Biopharm. , vol.20 , Issue.2 , pp. 147-169
    • Shafer, S.L.1    Gregg, K.2
  • 16
    • 0023692294 scopus 로고
    • Bayesian forecasting improves the prediction of intraoperative plasma concentrations of alfentanil
    • P. O. Maitre and D. R. Stanski, "Bayesian forecasting improves the prediction of intraoperative plasma concentrations of alfentanil," Anesthesiology, vol. 69, no. 5, pp. 652-659, 1988.
    • (1988) Anesthesiology , vol.69 , Issue.5 , pp. 652-659
    • Maitre, P.O.1    Stanski, D.R.2
  • 19
    • 0019273287 scopus 로고
    • Computer control of the infusion of vasoactive drugs
    • L. C. Sheppard, "Computer control of the infusion of vasoactive drugs," Ann. Biomed. Eng., vol. 8, pp. 431-444, 1980.
    • (1980) Ann. Biomed. Eng. , vol.8 , pp. 431-444
    • Sheppard, L.C.1
  • 21
    • 0022558012 scopus 로고
    • Multiple model adaptive control procedure for blood pressure control
    • W. G. He, H. Kaufman, and R. J. Roy, "Multiple model adaptive control procedure for blood pressure control," IEEE Trans. Biomed. Eng., vol. 33, no. 1, pp. 10-19, 1986.
    • (1986) IEEE Trans. Biomed. Eng. , vol.33 , Issue.1 , pp. 10-19
    • He, W.G.1    Kaufman, H.2    Roy, R.J.3
  • 23
    • 0037342417 scopus 로고    scopus 로고
    • Experimental studies on multiple-model predictive control for automated regulation of hemodynamic variables
    • R. R. Rao, B. Aufderheide, and B. W. Bequette, "Experimental studies on multiple-model predictive control for automated regulation of hemodynamic variables," IEEE Trans. Biomed. Eng., vol. 50, pp. 277-288, 2003.
    • (2003) IEEE Trans. Biomed. Eng. , vol.50 , pp. 277-288
    • Rao, R.R.1    Aufderheide, B.2    Bequette, B.W.3
  • 24
    • 0025457072 scopus 로고
    • Model reference adaptive control with constraints for postoperative blood pressure management
    • G. A. Pajunen, M. Steinmetz, and R. Shankar, "Model reference adaptive control with constraints for postoperative blood pressure management," IEEE Trans. Biomed. Eng., vol. 37, no. 7, pp. 679-687, 1990.
    • (1990) IEEE Trans. Biomed. Eng. , vol.37 , Issue.7 , pp. 679-687
    • Pajunen, G.A.1    Steinmetz, M.2    Shankar, R.3
  • 25
    • 0031195192 scopus 로고    scopus 로고
    • Adaptive control of arterial blood pressure with a learning controller based on multilayer neural networks
    • C. T. Chen, W. L. Lin, and T. S. Kuo, "Adaptive control of arterial blood pressure with a learning controller based on multilayer neural networks," IEEE Trans. Biomed. Eng., vol. 44, no. 7, pp. 601-609, 1997.
    • (1997) IEEE Trans. Biomed. Eng. , vol.44 , Issue.7 , pp. 601-609
    • Chen, C.T.1    Lin, W.L.2    Kuo, T.S.3
  • 26
    • 0026173334 scopus 로고
    • A controller for regulation of mean arterial blood pressure using optimum nitroprusside infusion rate
    • K. Behbehani and R. R. Cross, "A controller for regulation of mean arterial blood pressure using optimum nitroprusside infusion rate," IEEE Trans. Biomed. Eng., vol. 38, no. 6, pp. 513-521, 1991.
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , Issue.6 , pp. 513-521
    • Behbehani, K.1    Cross, R.R.2
  • 27
    • 0026900812 scopus 로고
    • Multiple-model adaptive predictive control of mean arterial pressure and cardiac output
    • C. Yu, R. J. Roy, H. Kaufman, and B. Bequette, "Multiple-model adaptive predictive control of mean arterial pressure and cardiac output," IEEE Trans. Biomed. Eng., vol. 39, no. 8, pp. 765-778, 1992.
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , Issue.8 , pp. 765-778
    • Yu, C.1    Roy, R.J.2    Kaufman, H.3    Bequette, B.4
  • 28
    • 0029278162 scopus 로고
    • Multiple drug hemodynamic control by means of a supervisory-fuzzy rule-based adaptive control system: Validation on a model
    • C. M. Held and R. J. Roy, "Multiple drug hemodynamic control by means of a supervisory-fuzzy rule-based adaptive control system: Validation on a model," IEEE Trans. Biomed. Eng., vol. 42, no. 4, pp. 371-385, 1995.
    • (1995) IEEE Trans. Biomed. Eng. , vol.42 , Issue.4 , pp. 371-385
    • Held, C.M.1    Roy, R.J.2
  • 30
    • 0031657514 scopus 로고    scopus 로고
    • A primer for EEG signal processing in anesthesia
    • I. J. Rampil, "A primer for EEG signal processing in anesthesia," Anesthesiology, vol. 89, no. 4, pp. 980-1002, 1998.
    • (1998) Anesthesiology , vol.89 , Issue.4 , pp. 980-1002
    • Rampil, I.J.1
  • 31
    • 0021039661 scopus 로고
    • Servo-controlled closed-circuit anaesthesia. A method for the automatic control anaesthesia produced by a volatile agent in oxygen
    • J. A. Ross, R. T. Wloch, D. C. White, and D. W. Hawes, "Servo-controlled closed-circuit anaesthesia. A method for the automatic control anaesthesia produced by a volatile agent in oxygen," Brit. J. Anaesth., vol. 55, no. 11, pp. 229-230, 1982.
    • (1982) Brit. J. Anaesth. , vol.55 , Issue.11 , pp. 229-230
    • Ross, J.A.1    Wloch, R.T.2    White, D.C.3    Hawes, D.W.4
  • 32
    • 0023366118 scopus 로고
    • Closed loop control of an anesthesia delivery system: Development and animal testing
    • R. G. Ritchie, E. A. Ernst, B. L. Pate, J. D. Pearson, and L. C. Shepherd, "Closed loop control of an anesthesia delivery system: Development and animal testing," IEEE Trans. Biomed. Eng., vol. 34, pp. 437-443, 1987.
    • (1987) IEEE Trans. Biomed. Eng. , vol.34 , pp. 437-443
    • Ritchie, R.G.1    Ernst, E.A.2    Pate, B.L.3    Pearson, J.D.4    Shepherd, L.C.5
  • 33
    • 0026035631 scopus 로고
    • Adaptive control of closed-circuit anesthesia
    • R. Vishnoi and R. J. Roy, "Adaptive control of closed-circuit anesthesia," IEEE Trans. Biomed. Eng., vol. 38, no. 1, pp. 39-47, 1991.
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , Issue.1 , pp. 39-47
    • Vishnoi, R.1    Roy, R.J.2
  • 34
    • 0026933248 scopus 로고
    • Adaptive control of multiplexed closedcircuit anesthesia
    • O. I. Jee and R. J. Roy, "Adaptive control of multiplexed closedcircuit anesthesia," IEEE Trans. Biomed. Eng., vol. 39, no. 10, pp. 1071-1080, 1992.
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , Issue.10 , pp. 1071-1080
    • Jee, O.I.1    Roy, R.J.2
  • 35
    • 0012208244 scopus 로고
    • Automatic electroencephalographic control of anesthesia (servo-anesthesia)
    • R. G. Bickford, "Automatic electroencephalographic control of anesthesia (servo-anesthesia)," Electroencephalographic Clin. Neurophysiol., vol. 3, pp. 83-86, 1951.
    • (1951) Electroencephalographic Clin. Neurophysiol. , vol.3 , pp. 83-86
    • Bickford, R.G.1
  • 36
    • 0023605947 scopus 로고
    • Closed-loop feedback control of methohexital anesthesia by quantitative EEG analysis in humans
    • H. Schwilden, J. Schuttler, and H. Stoeckel, "Closed-loop feedback control of methohexital anesthesia by quantitative EEG analysis in humans," Anesthesiology, vol. 67, pp. 341-347, 1987.
    • (1987) Anesthesiology , vol.67 , pp. 341-347
    • Schwilden, H.1    Schuttler, J.2    Stoeckel, H.3
  • 37
    • 0024601560 scopus 로고
    • Closed-loop feedback control of propofol anesthesia by quantitative EEG analysis in humans
    • H. Schwilden, H. Stoeckel, and J. Schuttler, "Closed-loop feedback control of propofol anesthesia by quantitative EEG analysis in humans," Brit. J. Anaesth., vol. 62, pp. 290-296, 1989.
    • (1989) Brit. J. Anaesth. , vol.62 , pp. 290-296
    • Schwilden, H.1    Stoeckel, H.2    Schuttler, J.3
  • 38
    • 0030963250 scopus 로고    scopus 로고
    • A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect
    • P. S. Sebel, E. Lang, I. J. Rampil, P. White, R. C. M. Jopling, N. T. Smith, P. S. Glass, and P. Manberg, "A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect," Anesth. Analg., vol. 84, no. 4, pp. 891-899, 1997.
    • (1997) Anesth. Analg. , vol.84 , Issue.4 , pp. 891-899
    • Sebel, P.S.1    Lang, E.2    Rampil, I.J.3    White, P.4    Jopling, R.C.M.5    Smith, N.T.6    Glass, P.S.7    Manberg, P.8
  • 39
    • 0030901893 scopus 로고    scopus 로고
    • Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in normal volunteers
    • P. S. Glass, M. Bloom, L. Kearse, C. Rosow, P. Sebel, and P. Manberg, "Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in normal volunteers," Anesthesiology, vol. 86, pp. 836-847, 1997.
    • (1997) Anesthesiology , vol.86 , pp. 836-847
    • Glass, P.S.1    Bloom, M.2    Kearse, L.3    Rosow, C.4    Sebel, P.5    Manberg, P.6
  • 40
    • 0034930564 scopus 로고    scopus 로고
    • Comparison of closed-loop controlled administration of propofol using BIS as the controlled variable versus "standard practice" controlled administration
    • M. Struys, T. De Smet, L. Versichelen, S. Van de Vilde, R. Van den Broecke, and E. Mortier, "Comparison of closed-loop controlled administration of propofol using BIS as the controlled variable versus "standard practice" controlled administration," Anesthesiology, vol. 95, pp. 6-17, 2001.
    • (2001) Anesthesiology , vol.95 , pp. 6-17
    • Struys, M.1    De Smet, T.2    Versichelen, L.3    Van De Vilde, S.4    Van Den Broecke, R.5    Mortier, E.6
  • 41
    • 0034934646 scopus 로고    scopus 로고
    • Automated anesthesia: Fact or fantasy?
    • P. S. A. Glass and I. J. Rampil, "Automated anesthesia: Fact or fantasy?" Anesthesiology, vol. 95, pp. 1-2, 2001.
    • (2001) Anesthesiology , vol.95 , pp. 1-2
    • Glass, P.S.A.1    Rampil, I.J.2
  • 42
    • 0036139025 scopus 로고    scopus 로고
    • Closed-loop control of anesthesia using bispectral index: Performance assessment in patients undergoing major orthopedic surgery under combined general and regional anesthesia
    • A. R. Absalom, N. Sutcliffe, and G. N. Kenny, "Closed-loop control of anesthesia using bispectral index: Performance assessment in patients undergoing major orthopedic surgery under combined general and regional anesthesia," Anesthesiology, vol. 96, no. 1, pp. 67-73, 2002.
    • (2002) Anesthesiology , vol.96 , Issue.1 , pp. 67-73
    • Absalom, A.R.1    Sutcliffe, N.2    Kenny, G.N.3
  • 43
    • 0032807943 scopus 로고    scopus 로고
    • Closed-loop control of propofol anaesthesia
    • G. N. Kenny and H. Mantzardis, "Closed-loop control of propofol anaesthesia," Brit. J. Anaesth., vol. 83, no. 2, pp. 223-228, 1999.
    • (1999) Brit. J. Anaesth. , vol.83 , Issue.2 , pp. 223-228
    • Kenny, G.N.1    Mantzardis, H.2
  • 44
    • 0033684670 scopus 로고    scopus 로고
    • Clinical implementation of advanced control in anaesthesia
    • D. A. Linkens, M. F. Abbod, and J. E. Peacock, "Clinical implementation of advanced control in anaesthesia," Trans. Inst. Meas. Control, vol. 22, pp. 303-330, 2000.
    • (2000) Trans. Inst. Meas. Control , vol.22 , pp. 303-330
    • Linkens, D.A.1    Abbod, M.F.2    Peacock, J.E.3
  • 46
    • 0038343448 scopus 로고    scopus 로고
    • Adaptive control for nonnegative and compartmental dynamical systems with applications to general anesthesia
    • W. M. Haddad, T. Hayakawa, and J. M. Bailey, "Adaptive control for nonnegative and compartmental dynamical systems with applications to general anesthesia," Int. J. Adapt. Control Signal Process., vol. 17, pp. 209-235, 2003.
    • (2003) Int. J. Adapt. Control Signal Process , vol.17 , pp. 209-235
    • Haddad, W.M.1    Hayakawa, T.2    Bailey, J.M.3
  • 47
    • 0142169348 scopus 로고    scopus 로고
    • Nonlinear adaptive control for intensive care unit sedation and operating room hypnosis
    • Denver, CO, June
    • _, "Nonlinear adaptive control for intensive care unit sedation and operating room hypnosis," in Proc. Amer. Contr. Conf., Denver, CO, June 2003, pp. 1808-1813.
    • (2003) Proc. Amer. Contr. Conf. , pp. 1808-1813
  • 48
    • 1542348597 scopus 로고    scopus 로고
    • Passivity-based neural network adaptive output feedback control for nonlinear nonnegative dynamical systems
    • Maui, HI, December Also in IEEE Trans. Neural Networks, submitted
    • T. Hayakawa, W. M. Haddad, J. M. Bailey, and N. Hovakimyan, "Passivity-based neural network adaptive output feedback control for nonlinear nonnegative dynamical systems," in Proc. IEEE Conf. Dec. Contr., Maui, HI, December 2003. Also in IEEE Trans. Neural Networks, submitted.
    • (2003) Proc. IEEE Conf. Dec. Contr.
    • Hayakawa, T.1    Haddad, W.M.2    Bailey, J.M.3    Hovakimyan, N.4
  • 49
    • 8744269036 scopus 로고    scopus 로고
    • Adaptive control for nonlinear compartmental dynamical systems with applications to clinical pharmacology
    • to appear
    • W. M. Haddad, T. Hayakawa, and J. M. Bailey, "Adaptive control for nonlinear compartmental dynamical systems with applications to clinical pharmacology," Automatica, to appear.
    • Automatica
    • Haddad, W.M.1    Hayakawa, T.2    Bailey, J.M.3
  • 50
    • 8744300808 scopus 로고    scopus 로고
    • Neural network adaptive dynamic output feedback control for nonlinear nonnegative systems using tapped delay memory units
    • Boston, MA, July
    • T. Hayakawa, W. M. Haddad, N. Hovakimyan, and J. M. Bailey, "Neural network adaptive dynamic output feedback control for nonlinear nonnegative systems using tapped delay memory units," in Proc. Amer. Contr. Conf., Boston, MA, July 2004.
    • (2004) Proc. Amer. Contr. Conf.
    • Hayakawa, T.1    Haddad, W.M.2    Hovakimyan, N.3    Bailey, J.M.4
  • 51
    • 0035710997 scopus 로고    scopus 로고
    • Stability and dissipativity theory for nonnegative dynamical systems: A thermodynamic framework for biological and physiological systems
    • Orlando, FL, December
    • W. M. Haddad, V. Chellaboina, and E. August, "Stability and dissipativity theory for nonnegative dynamical systems: A thermodynamic framework for biological and physiological systems," in Proc. IEEE Conf. Dec. Contr., Orlando, FL, December 2001, pp. 442-458.
    • (2001) Proc. IEEE Conf. Dec. Contr. , pp. 442-458
    • Haddad, W.M.1    Chellaboina, V.2    August, E.3
  • 52
    • 8744307486 scopus 로고    scopus 로고
    • Stability and dissipativity theory for nonnegative and compartmental dynamical systems with time delay
    • S.-I. Niculescu and K. Gu, Eds. Springer
    • W. M. Haddad and V. Chellaboina, "Stability and dissipativity theory for nonnegative and compartmental dynamical systems with time delay," in Advances in Time-Delay Systems, S.-I. Niculescu and K. Gu, Eds. Springer, pp. 423-437, 2004.
    • (2004) Advances in Time-Delay Systems , pp. 423-437
    • Haddad, W.M.1    Chellaboina, V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.