메뉴 건너뛰기




Volumn 59, Issue 11, 2004, Pages 840-844

Anodic adsorptive stripping voltammetry of the antihypertensive drug candesartan cilexetil at a glassy carbon electrode

Author keywords

[No Author keywords available]

Indexed keywords

CANDESARTAN HEXETIL; CARBON;

EID: 8744275468     PISSN: 00317144     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (16)

References (10)
  • 1
    • 0034897686 scopus 로고    scopus 로고
    • pKa determination of angiotensin II receptor antagonists (ARA II) by spectrofluorimetry
    • Cagigal E, Gonzalez L, Alonso RM, Jimenez RM (2001) pKa determination of angiotensin II receptor antagonists (ARA II) by spectrofluorimetry. J Pharm Biomed Anal 26: 477-486.
    • (2001) J Pharm Biomed Anal , vol.26 , pp. 477-486
    • Cagigal, E.1    Gonzalez, L.2    Alonso, R.M.3    Jimenez, R.M.4
  • 2
    • 0034525745 scopus 로고    scopus 로고
    • A high performance liquid chromatographic method for screening angitonsin II receptor antagonists in human urine
    • Gonzalez L, Alonso RM, Jimenez RM (2000) A high performance liquid chromatographic method for screening angitonsin II receptor antagonists in human urine. Chromatographia 52: 735-740.
    • (2000) Chromatographia , vol.52 , pp. 735-740
    • Gonzalez, L.1    Alonso, R.M.2    Jimenez, R.M.3
  • 3
    • 0037040623 scopus 로고    scopus 로고
    • Fast screening method for the determination of angiotensin II receptor antagonists in human plasma by high-performance liquid chromatography with fluorimetric detection
    • Gonzalez L, Lopez JA, Alonso RM, Jimenez RM (2002) Fast screening method for the determination of angiotensin II receptor antagonists in human plasma by high-performance liquid chromatography with fluorimetric detection. J Chromatogr A 949: 49-60.
    • (2002) J Chromatogr A , vol.949 , pp. 49-60
    • Gonzalez, L.1    Lopez, J.A.2    Alonso, R.M.3    Jimenez, R.M.4
  • 4
    • 0037427803 scopus 로고    scopus 로고
    • Optimization and validation of a micellar electrokinetic chromatographic method for the analysis of several angiotensin-II-receptor antagonists
    • Hillaert S, De Beer TRM, De Beer JO, Van den Bossche W (2003) Optimization and validation of a micellar electrokinetic chromatographic method for the analysis of several angiotensin-II-receptor antagonists. J Chromatogr A 984: 135-146.
    • (2003) J Chromatogr A , vol.984 , pp. 135-146
    • Hillaert, S.1    De Beer, T.R.M.2    De Beer, J.O.3    Van Den Bossche, W.4
  • 5
    • 0037032633 scopus 로고    scopus 로고
    • Optimization and validation of a capillary zone electrophoretic method for the analysis of several angiotensin-II-receptor antagonists
    • Hillaert S, Van den Bossche W (2002) Optimization and validation of a capillary zone electrophoretic method for the analysis of several angiotensin-II-receptor antagonists. J Chromatogr A 979: 323-333.
    • (2002) J Chromatogr A , vol.979 , pp. 323-333
    • Hillaert, S.1    Van Den Bossche, W.2
  • 6
    • 0345923833 scopus 로고    scopus 로고
    • Efficacy and safety of oral candesartan cilexetil in patients with congestive heart failure
    • Matsumori A (2003) Efficacy and safety of oral candesartan cilexetil in patients with congestive heart failure. Eur J Heart Failure 5: 669-677.
    • (2003) Eur J Heart Failure , vol.5 , pp. 669-677
    • Matsumori, A.1
  • 7
    • 0037382938 scopus 로고    scopus 로고
    • Anodic voltammetric assay of lansoprazole and omeprazole on a carbon paste electrode
    • Radi A (2003) Anodic voltammetric assay of lansoprazole and omeprazole on a carbon paste electrode. J Pharm Biomed Anal 31: 1007-1012.
    • (2003) J Pharm Biomed Anal , vol.31 , pp. 1007-1012
    • Radi, A.1
  • 9
    • 0032810866 scopus 로고    scopus 로고
    • Determination of candesartan cilexetil, candesartan and a metabolite in human plasma and urine by liquid chromatography and fluorimetric detection
    • Stenhoff H, Langerstrom PO, Andersen C (1999) Determination of candesartan cilexetil, candesartan and a metabolite in human plasma and urine by liquid chromatography and fluorimetric detection. J Chromatogr B 731: 411-417.
    • (1999) J Chromatogr B , vol.731 , pp. 411-417
    • Stenhoff, H.1    Langerstrom, P.O.2    Andersen, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.