메뉴 건너뛰기




Volumn 49, Issue 1, 2001, Pages 31-35

Postoperative astigmatism after intracapsular cataract surgery: Results of a randomised controlled trial in Nepal

Author keywords

AC IOL; Cataract surgery; Nepal; Postoperative astigmatism

Indexed keywords

ADOLESCENT; ADULT; ANTERIOR EYE SEGMENT; ARTICLE; ASTIGMATISM; CATARACT EXTRACTION; CHILD; CLINICAL TRIAL; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; EYE REFRACTION; FEMALE; FOLLOW UP; HUMAN; LENS CAPSULE; LENS IMPLANTATION; MALE; METHODOLOGY; MIDDLE AGED; NEPAL; PATHOPHYSIOLOGY; POSTOPERATIVE COMPLICATION; PRESCHOOL CHILD; PREVALENCE; RANDOMIZED CONTROLLED TRIAL; VISUAL ACUITY;

EID: 8744225741     PISSN: 03014738     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (14)
  • 1
    • 0023767758 scopus 로고
    • Prevalence and cause of blindness in northern Transvaal
    • Bucher PJM, Ijsselmuiden CB. Prevalence and cause of blindness in northern Transvaal. Br J Ophthalmol 1988;72:721-26.
    • (1988) Br J Ophthalmol , vol.72 , pp. 721-726
    • Bucher, P.J.M.1    Ijsselmuiden, C.B.2
  • 4
    • 0026970136 scopus 로고
    • Present challenges in the global prevention of blindness
    • Thylefors B. Present challenges in the global prevention of blindness. Aust NZ J Ophthalmol 1992;20:89-94.
    • (1992) Aust NZ J Ophthalmol , vol.20 , pp. 89-94
    • Thylefors, B.1
  • 6
    • 0023122057 scopus 로고
    • Post-operative astigmatism
    • Swinger CA. Post-operative astigmatism. Surv Ophthalmol 1987;31:219-48.
    • (1987) Surv Ophthalmol , vol.31 , pp. 219-248
    • Swinger, C.A.1
  • 7
    • 0027817552 scopus 로고
    • Factors affecting the visual outcome after cataract surgery
    • Lumme P, Laatikainen LT. Factors affecting the visual outcome after cataract surgery. Int Ophthalmol 1993;17:313-39.
    • (1993) Int Ophthalmol , vol.17 , pp. 313-339
    • Lumme, P.1    Laatikainen, L.T.2
  • 8
    • 8744313406 scopus 로고
    • Determination of intra ocular lens power
    • Peyman G, Sanders D, Goldberg M, editors. Philadelphia: WB Saunders
    • Drews R. Determination of intra ocular lens power. In: Peyman G, Sanders D, Goldberg M, editors. Principles and Practice of Ophthalmology. Philadelphia: WB Saunders, 1980. pp 665-66.
    • (1980) Principles and Practice of Ophthalmology , pp. 665-666
    • Drews, R.1
  • 9
    • 0019824485 scopus 로고
    • Planed myopic astigmatism as a substitute of for accommodation in pseudophakia
    • Huber C. Planed myopic astigmatism as a substitute of for accommodation in pseudophakia. Am Intraocul Implant Soc J 1981;7:244-49.
    • (1981) Am Intraocul Implant Soc J , vol.7 , pp. 244-249
    • Huber, C.1
  • 10
    • 8744230412 scopus 로고
    • Selection and calculation of intraocular lens power
    • Engelstein JM, editor. New York: Grune & Stratton
    • Terry C. Selection and calculation of intraocular lens power. In: Engelstein JM, editor. Cataract Surgery: Current Options and Problems. New York: Grune & Stratton, 1984. PP 65-71.
    • (1984) Cataract Surgery: Current Options and Problems , pp. 65-71
    • Terry, C.1
  • 11
    • 0015042871 scopus 로고
    • Cataract incision. Graded incision ab-externo compared with cataract knife
    • Witmer VR, Kreienbuhl R. Cataract incision. Graded incision ab-externo compared with cataract knife. Klin Monatsbl Augenheilkd 1971;158:465-70.
    • (1971) Klin Monatsbl Augenheilkd , vol.158 , pp. 465-470
    • Witmer, V.R.1    Kreienbuhl, R.2
  • 12
    • 0017794730 scopus 로고
    • Post-operative astigmatism and the operating microscope
    • Robertson IF. Post-operative astigmatism and the operating microscope. Adv Ophthalmol 1978;37:117-21.
    • (1978) Adv Ophthalmol , vol.37 , pp. 117-121
    • Robertson, I.F.1
  • 13
    • 0018956856 scopus 로고
    • Intra-ocular implants. Post-operative astigmatism
    • Gibson MJ. Intra-ocular implants. Post-operative astigmatism. Br J Ophthalmol 1980;64:318-21.
    • (1980) Br J Ophthalmol , vol.64 , pp. 318-321
    • Gibson, M.J.1
  • 14
    • 0022352359 scopus 로고
    • Corneal astigmatism induced by oversized rigid anterior chamber implants
    • Abdel-Hakim AS. Corneal astigmatism induced by oversized rigid anterior chamber implants. Am Intra-ocu. Implant Soc J 1985;11:474-79.
    • (1985) Am Intra-ocu. Implant Soc J , vol.11 , pp. 474-479
    • Abdel-Hakim, A.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.