메뉴 건너뛰기




Volumn 109, Issue 2, 2004, Pages 291-298

Intramural comparison of NIST laser and optical fiber power calibrations

Author keywords

Absolute responsivity; Calorimeter; Cryogenic radiometer; Intercomparison; Laser; Optical fiber; Optical power; Pyroelectric detector; Spectral responsivity

Indexed keywords

CALIBRATION; CRYOGENICS; DETECTORS; LASER APPLICATIONS; PHOTODIODES; RADIOMETERS;

EID: 8644252587     PISSN: 1044677X     EISSN: None     Source Type: Journal    
DOI: 10.6028/jres.109.019     Document Type: Article
Times cited : (6)

References (18)
  • 2
    • 0039129478 scopus 로고    scopus 로고
    • A transfer standard for optical fiber power metrology
    • J. H. Lehman and X. Li, A transfer standard for optical fiber power metrology, Eng. Lab. Notes in Opt. & Phot. News 10, (5) (1999), archived in Appl. Opt. 38, 7164-7166 (1999).
    • (1999) Eng. Lab. Notes in Opt. & Phot. News , vol.10 , Issue.5
    • Lehman, J.H.1    Li, X.2
  • 3
    • 0001349695 scopus 로고    scopus 로고
    • J. H. Lehman and X. Li, A transfer standard for optical fiber power metrology, Eng. Lab. Notes in Opt. & Phot. News 10, (5) (1999), archived in Appl. Opt. 38, 7164-7166 (1999).
    • (1999) Appl. Opt. , vol.38 , pp. 7164-7166
  • 4
    • 0036848624 scopus 로고    scopus 로고
    • Optical trap detector for calibration of optical fiber powermeters: Coupling efficiency
    • J. H. Lehman and C. L. Cromer, Optical trap detector for calibration of optical fiber powermeters: coupling efficiency, Appl. Opt. 31, 6531-6536 (2002).
    • (2002) Appl. Opt. , vol.31 , pp. 6531-6536
    • Lehman, J.H.1    Cromer, C.L.2
  • 5
    • 8644238511 scopus 로고    scopus 로고
    • Calibration service for spectral responsivity of laser and optical-fiber power meters at wavelengths between 0.4 μm and 1.8 μm
    • J. H. Lehman, Calibration Service for Spectral Responsivity of Laser and Optical-Fiber Power Meters at Wavelengths Between 0.4 μm and 1.8 μm, NIST Spec. Publ. 250-53 (1999) pp. 1-39.
    • (1999) NIST Spec. Publ. , vol.250 , Issue.53 , pp. 1-39
    • Lehman, J.H.1
  • 6
    • 0002727477 scopus 로고
    • Guidelines for evaluating and expressing the uncertainty of NIST measurement results
    • B. N. Taylor and C. E. Kuyatt, Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, NIST Technical Note 1297 (1994) p. 5.
    • (1994) NIST Technical Note , vol.1297 , pp. 5
    • Taylor, B.N.1    Kuyatt, C.E.2
  • 7
    • 0026224347 scopus 로고
    • Trap detectors and their properties
    • N. P. Fox, Trap detectors and their properties, Metrologia 28, 197-202 (1991).
    • (1991) Metrologia , vol.28 , pp. 197-202
    • Fox, N.P.1
  • 9
    • 0014785395 scopus 로고
    • Theory of isoperibol calorimetry for laser power and energy measurements
    • E. D. West and K. L. Churney, Theory of Isoperibol Calorimetry for Laser Power and Energy Measurements, J. Appl. Phys. 41, 2705-2712 (1970).
    • (1970) J. Appl. Phys. , vol.41 , pp. 2705-2712
    • West, E.D.1    Churney, K.L.2
  • 10
    • 0017521804 scopus 로고
    • Evaluating the inequivalence and a computational simplification for the NBS laser energy standards
    • E. G. Johnson, Jr., Evaluating the inequivalence and a computational simplification for the NBS laser energy standards, Appl. Opt. 16, 2315-2321 (1977).
    • (1977) Appl. Opt. , vol.16 , pp. 2315-2321
    • Johnson Jr., E.G.1
  • 11
    • 8644253853 scopus 로고    scopus 로고
    • High accuracy laser power and energy meter calibration service
    • D. L. Livigni, High accuracy laser power and energy meter calibration service, NIST Spec. Publ. 250-62 (2003) pp. 1-144.
    • (2003) NIST Spec. Publ. , vol.250 , Issue.62 , pp. 1-144
    • Livigni, D.L.1
  • 12
    • 5244331728 scopus 로고    scopus 로고
    • Pyroelectric trap detector for spectral responsivity measurements
    • J. H. Lehman, Pyroelectric trap detector for spectral responsivity measurements, Eng. Lab. Notes, Opt. in Phot. News 8, (11), archived in Appl. Opt. 36, 9117-9118 (1997).
    • Eng. Lab. Notes, Opt. in Phot. News , vol.8 , Issue.11
    • Lehman, J.H.1
  • 13
    • 85010178280 scopus 로고    scopus 로고
    • J. H. Lehman, Pyroelectric trap detector for spectral responsivity measurements, Eng. Lab. Notes, Opt. in Phot. News 8, (11), archived in Appl. Opt. 36, 9117-9118 (1997).
    • (1997) Appl. Opt. , vol.36 , pp. 9117-9118
  • 15
    • 12344268414 scopus 로고    scopus 로고
    • NIST measurement ervices: Optical fiber power meter calibrations at NIST
    • I. Vayshenker, X. Li, D. J. Livigni, T. R. Scott, and C. L. Cromer, NIST Measurement ervices: Optical Fiber Power Meter Calibrations at NIST, NIST Spec. Publ. 250-54 (1999) pp. 1-36.
    • (1999) NIST Spec. Publ. , vol.250 , Issue.54 , pp. 1-36
    • Vayshenker, I.1    Li, X.2    Livigni, D.J.3    Scott, T.R.4    Cromer, C.L.5
  • 17
    • 0032279761 scopus 로고    scopus 로고
    • Thermal characterization of a cryogenic radiometer and comparison with a laser calorimeter
    • D. J. Livigni, C. L. Cromer, T. R. Scott, B. Carol Johnson, and Z. M. Zhang, Thermal characterization of a cryogenic radiometer and comparison with a laser calorimeter, Metrologia 35, 819-827 (1998).
    • (1998) Metrologia , vol.35 , pp. 819-827
    • Livigni, D.J.1    Cromer, C.L.2    Scott, T.R.3    Johnson, B.C.4    Zhang, Z.M.5
  • 18
    • 0034474360 scopus 로고    scopus 로고
    • Optical tunnel trap detector for radiometric measurements
    • J. H. Lehman and C. L. Cromer, Optical tunnel trap detector for radiometric measurements, Metrologia 37, 477-480 (2000).
    • (2000) Metrologia , vol.37 , pp. 477-480
    • Lehman, J.H.1    Cromer, C.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.