메뉴 건너뛰기




Volumn 23, Issue 3, 2004, Pages 489-494

Radiation exposure of personnel during intraoperative radiotherapy (IORT): Radiation protection aspects

Author keywords

Intraoperative radiotherapy; Safe radiation exposure; Weight factors for neutron spectra

Indexed keywords

ARTICLE; BEAM THERAPY; CANCER RADIOTHERAPY; INTRAOPERATIVE PERIOD; LINEAR ACCELERATOR; NEUTRON RADIATION; PERSONNEL; PHOTON; PRIORITY JOURNAL; RADIATION ATTENUATION; RADIATION DOSE; RADIATION EXPOSURE; RADIATION PROTECTION; RADIOLOGICAL TECHNOLOGIST; RADIOLOGY DEPARTMENT; SURGICAL PATIENT;

EID: 8544246436     PISSN: 03929078     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (13)

References (8)
  • 2
    • 0028832257 scopus 로고
    • Intraoperative electron beam radiation therapy: Technique, dosimetry, and dose specification: Report of task force 48 of the radiation therapy committee, American Association of Physicists in Medicine
    • Palta J.R., Biggs P.J., Hazle J.D., et al.: Intraoperative electron beam radiation therapy: Technique, dosimetry, and dose specification: Report of task force 48 of the radiation therapy committee, American Association of Physicists in Medicine. Int. J. Radiat. Oncol. Biol. Phys. 33:725-746, 1995.
    • (1995) Int. J. Radiat. Oncol. Biol. Phys. , vol.33 , pp. 725-746
    • Palta, J.R.1    Biggs, P.J.2    Hazle, J.D.3
  • 4
    • 0003511916 scopus 로고
    • Neutron contamination from medical electron accelerators
    • National Council on Radiation Protection and measurements Neutron contamination from medical electron accelerators. NCRP Report No. 79, 1984.
    • (1984) NCRP Report No. 79
  • 6
    • 0003639048 scopus 로고
    • Radiation Dosimetry: Electron beams with energies between 1 and 50MeV
    • International Commission on Radiation Units and Measurements Radiation Dosimetry: electron beams with energies between 1 and 50MeV. ICRU Report No. 35, 1984.
    • (1984) ICRU Report No. 35