Volumn Part F952, Issue , 2009, Pages 281-303

The First Commercial Brain–Computer Interface Environment

Author keywords

Biosignal Amplifier; Brain Computer Interface; Common Spatial Pattern (CSP); Ground Leakage Current; Motor Imagery

Indexed keywords


EID: 85165886614     PISSN: 16123018     EISSN: 21976619     Source Type: Book Series    
DOI: 10.1007/978-3-642-02091-9_16     Document Type: Chapter
Times cited : (3)

References (23)
  • 2
    • 0034470419 scopus 로고    scopus 로고
    • Real-time EEG analysis with subject-specific spatial patterns for a brain computer interface (BCI)
    • C. Guger, H. Ramoser, and G. Pfurtscheller, Real-time EEG analysis with subject-specific spatial patterns for a brain computer interface (BCI). IEEE Trans Neural Syst Rehabil Eng, 8, 447–456, (2000).
    • (2000) IEEE Trans Neural Syst Rehabil Eng , vol.8 , pp. 447-456
    • Guger, C.1    Ramoser, H.2    Pfurtscheller, G.3
  • 3
    • 6344249527 scopus 로고    scopus 로고
    • A brain-computer interface using electrocorticographic signals in humans
    • E.C. Leuthardt, G. Schalk, J.R. Wolpaw, J.G. Ojemann, and D.W. Moran, A brain-computer interface using electrocorticographic signals in humans. J Neural Eng, 1, 63–71, (2004).
    • (2004) J Neural Eng , vol.1 , pp. 63-71
    • Leuthardt, E.C.1    Schalk, G.2    Wolpaw, J.R.3    Ojemann, J.G.4    Moran, D.W.5
  • 5
    • 28444496378 scopus 로고    scopus 로고
    • Steady-state visual evoked potential (SSVEP)-based communication: Impact of harmonic frequency components
    • G.R. Muller-Putz, R. Scherer, C. Brauneis, and G. Pfurtscheller, Steady-state visual evoked potential (SSVEP)-based communication: impact of harmonic frequency components. J Neural Eng, 2(4), 123–130, (2005).
    • (2005) J Neural Eng , vol.2 , Issue.4 , pp. 123-130
    • Muller-Putz, G.R.1    Scherer, R.2    Brauneis, C.3    Pfurtscheller, G.4
  • 7
    • 33644982444 scopus 로고    scopus 로고
    • Robust classification of EEG signal for brain-computer interface
    • M. Thulasidas, G. Cuntai, and W. Jiankang, Robust classification of EEG signal for brain-computer interface. IEEE Trans Neural Syst Rehabil Eng, 14(1), 24–29, 2006.
    • (2006) IEEE Trans Neural Syst Rehabil Eng , vol.14 , Issue.1 , pp. 24-29
    • Thulasidas, M.1    Cuntai, G.2    Jiankang, W.3
  • 14
    • 0038012676 scopus 로고    scopus 로고
    • Brain-computer interface (BCI) operation: Optimizing information transfer rates
    • D.J. McFarland, W.A. Sarnacki, and J.R. Wolpaw, Brain-computer interface (BCI) operation: optimizing information transfer rates. Biol Psychol, 63(3), 237–251, (2003).
    • (2003) Biol Psychol , vol.63 , Issue.3 , pp. 237-251
    • McFarland, D.J.1    Sarnacki, W.A.2    Wolpaw, J.R.3
  • 15
    • 33846917712 scopus 로고    scopus 로고
    • Laboratory PC and mobile pocket PC brain-computer interface architectures
    • G. Edlinger, and C. Guger: Laboratory PC and mobile pocket PC brain-computer interface architectures. Conf Proc IEEE Eng Med Biol Soc, 5, 5347–5350, (2005).
    • (2005) Conf Proc IEEE Eng Med Biol Soc , vol.5 , pp. 5347-5350
    • Edlinger, G.1    Guger, C.2
  • 16
    • 33846006913 scopus 로고    scopus 로고
    • A P300 event-related potential brain-computer interface (BCI): The effects of matrix size and inter stimulus interval on performance
    • E.W. Sellers, D.J. Krusienski, D.J. McFarland, T.M. Vaughan, and J.R. Wolpaw, A P300 event-related potential brain-computer interface (BCI): the effects of matrix size and inter stimulus interval on performance. Biol Psychol, 73(3), 242–252, (2006).
    • (2006) Biol Psychol , vol.73 , Issue.3 , pp. 242-252
    • Sellers, E.W.1    Krusienski, D.J.2    McFarland, D.J.3    Vaughan, T.M.4    Wolpaw, J.R.5
  • 17
    • 0032607559 scopus 로고    scopus 로고
    • The ten-twenty electrode system of the International Federation. The International Federation of Clinical Neurophysiology
    • G. Klem, H. Lüders, H. Jasper, and C. Elger, The ten-twenty electrode system of the International Federation. The International Federation of Clinical Neurophysiology. Cleveland Clinic Foundation, 52, 3–6, (1999).
    • (1999) Cleveland Clinic Foundation , vol.52 , pp. 3-6
    • Klem, G.1    Lüders, H.2    Jasper, H.3    Elger, C.4
  • 18
    • 0034868606 scopus 로고    scopus 로고
    • Hidden Markov Models for online classification of single trial EEG data
    • B. Obermaier, C. Guger, C. Neuper, and G. Pfurtscheller, Hidden Markov Models for online classification of single trial EEG data. Pattern Recogn Lett, 22, 1299–1309, (2001).
    • (2001) Pattern Recogn Lett , vol.22 , pp. 1299-1309
    • Obermaier, B.1    Guger, C.2    Neuper, C.3    Pfurtscheller, G.4
  • 22
    • 33644750479 scopus 로고    scopus 로고
    • A P300-based brain-computer interface: initial tests by ALS patients
    • E.W. Sellers and E. Donchin, A P300-based brain-computer interface: initial tests by ALS patients. Clin Neurophysiol,. 117(3), 538–548, (2006).
    • (2006) Clin Neurophysiol , vol.117 , Issue.3 , pp. 538-548
    • Sellers, E.W.1    Donchin, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.