메뉴 건너뛰기




Volumn , Issue , 2001, Pages 110-113

Design of a compact Shack-Hartmann aberrometer for realtime measurement of aberrations in human eyes

Author keywords

[No Author keywords available]

Indexed keywords

ABERROMETERS; CLINICAL ENVIRONMENTS; GRID PATTERN; HUMAN EYE; MEASUREMENTS OF; OPTICAL AND MECHANICAL DESIGNS; REAL TIME MEASUREMENTS; SHACK-HARTMANN; WAVEFRONT SENSOR;

EID: 85135957854     PISSN: None     EISSN: 21622701     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (9)

References (11)
  • 1
    • 0028469062 scopus 로고
    • Objective measurement of wave aberrations of the human eye with the use of a Hartmann-Shack wave-front sensor
    • J. Liang, B. Grimm, S. Goelz, J.E Bille, "Objective measurement of wave aberrations of the human eye with the use of a Hartmann-Shack wave-front sensor," J. Opt. Soc. Am. A, 11(7), 1949-1957 (1994).
    • (1994) J. Opt. Soc. Am. A , vol.11 , Issue.7 , pp. 1949-1957
    • Liang, J.1    Grimm, B.2    Goelz, S.3    Bille, J.E4
  • 2
    • 0031279198 scopus 로고    scopus 로고
    • Aberrations and retinal image quality of the normal human eye
    • J. Liang, D.R. Williams, "Aberrations and retinal image quality of the normal human eye," J. Opt. Soc. Am. A, 14(11), 2873-2883 (1997).
    • (1997) J. Opt. Soc. Am. A , vol.14 , Issue.11 , pp. 2873-2883
    • Liang, J.1    Williams, D.R.2
  • 3
    • 0031260752 scopus 로고    scopus 로고
    • Supernormal vision and high-resolution retinal imaging through adaptive optics
    • J. Liang, D.R. Williams, D.T. Miller, "Supernormal vision and high-resolution retinal imaging through adaptive optics," J. Opt. Soc. Am. A, 14(11), 2884-2892 (1997).
    • (1997) J. Opt. Soc. Am. A , vol.14 , Issue.11 , pp. 2884-2892
    • Liang, J.1    Williams, D.R.2    Miller, D.T.3
  • 4
    • 0032776742 scopus 로고    scopus 로고
    • Clinical Application of the Shack-Hartmann Aberrometer
    • L.N. Thibos, X. Hong, "Clinical Application of the Shack-Hartmann Aberrometer," Optometry and Vision Science 76(12), 817-825 (1999).
    • (1999) Optometry and Vision Science , vol.76 , Issue.12 , pp. 817-825
    • Thibos, L.N.1    Hong, X.2
  • 5
    • 0032160387 scopus 로고    scopus 로고
    • Comparison of the eye's wave-front aberration measured psychophiysically and with the Shack-Hartmann wave-front sensor
    • T.O. Salomon, L.N. Thibos, A. Bradley, "Comparison of the eye's wave-front aberration measured psychophiysically and with the Shack-Hartmann wave-front sensor," J. Opt. Soc. Am. A, 15(9), 2457-2465 (1998).
    • (1998) J. Opt. Soc. Am. A , vol.15 , Issue.9 , pp. 2457-2465
    • Salomon, T.O.1    Thibos, L.N.2    Bradley, A.3
  • 6
    • 0034202622 scopus 로고    scopus 로고
    • Laser Ray Tracing versus Hartmann-Shack sensor for measuring optical aberrations in the human eye
    • E. Moreno-Barriuso, R. Navarro, "Laser Ray Tracing versus Hartmann-Shack sensor for measuring optical aberrations in the human eye," J. Opt. Soc. Am. A, 17(6), 974-85 (2000).
    • (2000) J. Opt. Soc. Am. A , vol.17 , Issue.6 , pp. 974-985
    • Moreno-Barriuso, E.1    Navarro, R.2
  • 8
    • 0000667653 scopus 로고
    • Production and Use of a Lenticular Hartmann Screen
    • R.V. Shack, B.C. Piatt, "Production and Use of a Lenticular Hartmann Screen," J. Opt. Soc. Am., p. 656, (1971).
    • (1971) J. Opt. Soc. Am , pp. 656
    • Shack, R.V.1    Piatt, B.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.