메뉴 건너뛰기




Volumn 36, Issue 5, 2003, Pages 717-722

On-line fault isolation algorithm for industrial processes

Author keywords

Decomposition; Diagnostic programs; Dynamic behaviour; Fault isolation; Industrial production systems

Indexed keywords

DECOMPOSITION; FAULT DETECTION; FUZZY LOGIC; PROGRAM DIAGNOSTICS; VIBRATION MEASUREMENT;

EID: 85064443195     PISSN: 14746670     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1016/S1474-6670(17)36577-1     Document Type: Conference Paper
Times cited : (4)

References (13)
  • 2
    • 0025421966 scopus 로고
    • Fault diagnosis in dynamic systems using analytical and knowledge-based redundancy
    • P.M. Frank Fault diagnosis in dynamic systems using analytical and knowledge-based redundancy. Automatica 26 1990 459 474
    • (1990) Automatica , vol.26 , pp. 459-474
    • Frank, P.M.1
  • 5
    • 0028484094 scopus 로고
    • Algorithm of fault detection and isolation applied for evaporation unit in sugar factory
    • J.M. Kościelny, and A. Pieniazek Algorithm of Fault Detection and Isolation Applied for Evaporation Unit in Sugar Factory. Control Engineering Practice vo1.2 No.4 1994 649 657
    • (1994) Control Engineering Practice , vol.2 , Issue.4 , pp. 649-657
    • Kościelny, J.M.1    Pieniazek, A.2
  • 6
    • 0029305084 scopus 로고
    • Fault isolation in industrial processes by dynamic table of states method
    • J.M. Kościelny Fault Isolation in Industrial Processes by Dynamic Table of States Method. Automatica vo1.31 No.5 1995 747 753
    • (1995) Automatica , vol.31 , Issue.5 , pp. 747-753
    • Kościelny, J.M.1
  • 7
    • 70349287272 scopus 로고    scopus 로고
    • Diagnostics of processes in decentralized structures
    • J.M. Kościelny Diagnostics of Processes in Decentralized Structures. Archives of Control Sciences Vol, 7 No3/4 1998
    • (1998) Archives of Control Sciences , vol.7
    • Kościelny, J.M.1
  • 8
    • 0012310585 scopus 로고    scopus 로고
    • Application of fuzzy logic fault isolation in a three-tank system
    • Bejing, Chiny P-7e-05-l
    • thWorld Congress IFAC Bejing, Chiny 1999 73 78 P-7e-05-l
    • (1999) thWorld Congress IFAC , pp. 73-78
    • Kościelny, J.M.1
  • 13
    • 84947484273 scopus 로고    scopus 로고
    • Fuzzy neural network based diagnotic system application for three-tank system
    • Porto, Portugal
    • M. Syfert, and J.M. Kościelny Fuzzy neural network based diagnotic system application for three-tank system. European Control Conference 2001 Porto, Portugal 2001 1631 1636
    • (2001) European Control Conference 2001 , pp. 1631-1636
    • Syfert, M.1    Kościelny, J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.