메뉴 건너뛰기




Volumn 33, Issue 10, 2018, Pages 1787-1794

Can the same controlled attenuation parameter cut-offs be used for M and XL probes for diagnosing hepatic steatosis?

Author keywords

CAP; controlled attenuation parameter; fibroscan; M probe; steatosis; XL probe

Indexed keywords

ADULT; ARTICLE; CHRONIC LIVER DISEASE; COMPARATIVE STUDY; CONTROLLED ATTENUATION PARAMETER; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DIAGNOSTIC VALUE; FATTY LIVER; FEMALE; HUMAN; LIVER BIOPSY; LIVER EXAMINATION; MAJOR CLINICAL STUDY; MALE; MIDDLE AGED; NONALCOHOLIC FATTY LIVER; OBESITY; PARAMETERS; PREDICTIVE VALUE; PRIORITY JOURNAL; PROSPECTIVE STUDY; REFERENCE VALUE; SENSITIVITY AND SPECIFICITY; TRANSIENT ELASTOGRAPHY; ELASTICITY; ELASTOGRAPHY; FIBROSIS; LIVER; PATHOLOGY; PATHOPHYSIOLOGY; PROCEDURES; SEVERITY OF ILLNESS INDEX;

EID: 85046442473     PISSN: 08159319     EISSN: 14401746     Source Type: Journal    
DOI: 10.1111/jgh.14150     Document Type: Article
Times cited : (42)

References (16)
  • 1
    • 41349094999 scopus 로고    scopus 로고
    • Performance of transient elastography for the staging of liver fibrosis: a meta-analysis
    • e8.
    • Friedrich-Rust M, Ong MF, Martens S et al. Performance of transient elastography for the staging of liver fibrosis: a meta-analysis. Gastroenterology 2008; 134: 960–974 e8
    • (2008) Gastroenterology , vol.134 , pp. 960-974
    • Friedrich-Rust, M.1    Ong, M.F.2    Martens, S.3
  • 2
    • 85038576851 scopus 로고    scopus 로고
    • The diagnosis and management of nonalcoholic fatty liver disease: practice guidance from the American Association for the Study of Liver Diseases
    • Chalasani N, Younossi Z, Lavine JE et al. The diagnosis and management of nonalcoholic fatty liver disease: practice guidance from the American Association for the Study of Liver Diseases. Hepatology 2017
    • (2017) Hepatology
    • Chalasani, N.1    Younossi, Z.2    Lavine, J.E.3
  • 3
    • 84964038722 scopus 로고    scopus 로고
    • EASL-EASD-EASO Clinical Practice Guidelines for the management of non-alcoholic fatty liver disease
    • Liver EAftSot, Diabetes EAftSo. EASL-EASD-EASO Clinical Practice Guidelines for the management of non-alcoholic fatty liver disease. Obes. Facts 2016; 9: 65–90
    • (2016) Obes. Facts , vol.9 , pp. 65-90
  • 4
    • 85042761555 scopus 로고    scopus 로고
    • The Asia-Pacific Working Party on Nonalcoholic Fatty Liver Disease Guidelines 2017 Part 1: definition, risk factors and assessment
    • Wong VWS, Chan WK, Chitturi S et al. The Asia-Pacific Working Party on Nonalcoholic Fatty Liver Disease Guidelines 2017 Part 1: definition, risk factors and assessment. J. Gastroenterol. Hepatol. 2017
    • (2017) J. Gastroenterol. Hepatol.
    • Wong, V.W.S.1    Chan, W.K.2    Chitturi, S.3
  • 5
    • 84992494136 scopus 로고    scopus 로고
    • Expanding consensus in portal hypertension
    • De Franchis R. Expanding consensus in portal hypertension. J. Hepatol. 2015; 63: 743–752
    • (2015) J. Hepatol. , vol.63 , pp. 743-752
    • De Franchis, R.1
  • 6
    • 77958154016 scopus 로고    scopus 로고
    • Controlled attenuation parameter (CAP): a novel VCTE™ guided ultrasonic attenuation measurement for the evaluation of hepatic steatosis: preliminary study and validation in a cohort of patients with chronic liver disease from various causes
    • Sasso M, Beaugrand M, De Ledinghen V et al. Controlled attenuation parameter (CAP): a novel VCTE™ guided ultrasonic attenuation measurement for the evaluation of hepatic steatosis: preliminary study and validation in a cohort of patients with chronic liver disease from various causes. Ultrasound Med. Biol. 2010; 36: 1825–1835
    • (2010) Ultrasound Med. Biol. , vol.36 , pp. 1825-1835
    • Sasso, M.1    Beaugrand, M.2    De Ledinghen, V.3
  • 7
    • 84904346796 scopus 로고    scopus 로고
    • Controlled attenuation parameter for the detection and quantification of hepatic steatosis in nonalcoholic fatty liver disease
    • Chan WK, Mustapha N, Raihan N, Mahadeva S. Controlled attenuation parameter for the detection and quantification of hepatic steatosis in nonalcoholic fatty liver disease. J. Gastroenterol. Hepatol. 2014; 29: 1470–1476
    • (2014) J. Gastroenterol. Hepatol. , vol.29 , pp. 1470-1476
    • Chan, W.K.1    Mustapha, N.2    Raihan, N.3    Mahadeva, S.4
  • 8
    • 84861961483 scopus 로고    scopus 로고
    • Controlled Attenuation Parameter (CAP): a noninvasive method for the detection of hepatic steatosis based on transient elastography
    • Myers RP, Pollett A, Kirsch R et al. Controlled Attenuation Parameter (CAP): a noninvasive method for the detection of hepatic steatosis based on transient elastography. Liver Int. 2012; 32: 902–910
    • (2012) Liver Int. , vol.32 , pp. 902-910
    • Myers, R.P.1    Pollett, A.2    Kirsch, R.3
  • 9
    • 84941788436 scopus 로고    scopus 로고
    • Liver steatosis assessed by controlled attenuation parameter (CAP) measured with the XL probe of the FibroScan: a pilot study assessing diagnostic accuracy
    • Sasso M, Audière S, Kemgang A et al. Liver steatosis assessed by controlled attenuation parameter (CAP) measured with the XL probe of the FibroScan: a pilot study assessing diagnostic accuracy. Ultrasound Med. Biol. 2016; 42: 92–103
    • (2016) Ultrasound Med. Biol. , vol.42 , pp. 92-103
    • Sasso, M.1    Audière, S.2    Kemgang, A.3
  • 10
    • 85011602148 scopus 로고    scopus 로고
    • Controlled attenuation parameter using the FibroScan® XL probe for quantification of hepatic steatosis for non-alcoholic fatty liver disease in an Asian population
    • Chan W-K, Nik Mustapha NR, Wong GL-H, Wong VW-S, Mahadeva S. Controlled attenuation parameter using the FibroScan® XL probe for quantification of hepatic steatosis for non-alcoholic fatty liver disease in an Asian population. United European Gastroenterol. J. 2017; 5: 76–85
    • (2017) United European Gastroenterol. J. , vol.5 , pp. 76-85
    • Chan, W.-K.1    Nik Mustapha, N.R.2    Wong, G.L.-H.3    Wong, V.W.-S.4    Mahadeva, S.5
  • 11
    • 85010832078 scopus 로고    scopus 로고
    • Individual patient data meta-analysis of controlled attenuation parameter (CAP) technology for assessing steatosis
    • Karlas T, Petroff D, Sasso M et al. Individual patient data meta-analysis of controlled attenuation parameter (CAP) technology for assessing steatosis. J. Hepatol. 2017; 66: 1022–1030
    • (2017) J. Hepatol. , vol.66 , pp. 1022-1030
    • Karlas, T.1    Petroff, D.2    Sasso, M.3
  • 12
    • 0347992980 scopus 로고    scopus 로고
    • The new BMI criteria for asians by the regional office for the western pacific region of WHO are suitable for screening of overweight to prevent metabolic syndrome in elder Japanese workers
    • Anuurad E, Shiwaku K, Nogi A et al. The new BMI criteria for asians by the regional office for the western pacific region of WHO are suitable for screening of overweight to prevent metabolic syndrome in elder Japanese workers. J. Occup. Health 2003; 45: 335–343
    • (2003) J. Occup. Health , vol.45 , pp. 335-343
    • Anuurad, E.1    Shiwaku, K.2    Nogi, A.3
  • 13
    • 25144459980 scopus 로고    scopus 로고
    • The metabolic syndrome—a new worldwide definition
    • Alberti KGM, Zimmet P, Shaw J. The metabolic syndrome—a new worldwide definition. The Lancet 2005; 366: 1059–1062
    • (2005) The Lancet , vol.366 , pp. 1059-1062
    • Alberti, K.G.M.1    Zimmet, P.2    Shaw, J.3
  • 14
    • 20044374023 scopus 로고    scopus 로고
    • Design and validation of a histological scoring system for nonalcoholic fatty liver disease
    • Kleiner DE, Brunt EM, Van Natta M et al. Design and validation of a histological scoring system for nonalcoholic fatty liver disease. Hepatology 2005; 41: 1313–1321
    • (2005) Hepatology , vol.41 , pp. 1313-1321
    • Kleiner, D.E.1    Brunt, E.M.2    Van Natta, M.3
  • 15
    • 84874473244 scopus 로고    scopus 로고
    • Determination of reliability criteria for liver stiffness evaluation by transient elastography
    • Boursier J, Zarski JP, de Ledinghen V et al. Determination of reliability criteria for liver stiffness evaluation by transient elastography. Hepatology 2013; 57: 1182–1191
    • (2013) Hepatology , vol.57 , pp. 1182-1191
    • Boursier, J.1    Zarski, J.P.2    de Ledinghen, V.3
  • 16
    • 85020065411 scopus 로고    scopus 로고
    • Controlled attenuation parameter (CAP) with the XL probe of the Fibroscan(R): a comparative study with the M probe and liver biopsy
    • de Ledinghen V, Hiriart JB, Vergniol J, Merrouche W, Bedossa P, Paradis V. Controlled attenuation parameter (CAP) with the XL probe of the Fibroscan(R): a comparative study with the M probe and liver biopsy. Dig. Dis. Sci. 2017
    • (2017) Dig. Dis. Sci.
    • de Ledinghen, V.1    Hiriart, J.B.2    Vergniol, J.3    Merrouche, W.4    Bedossa, P.5    Paradis, V.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.