메뉴 건너뛰기




Volumn 33, Issue 3, 2018, Pages 2113-2126

An Improved Transformer Winding Tap Injection DSTATCOM Topology for Medium-Voltage Reactive Power Compensation

Author keywords

Cascaded multilevel converter (CMC); distribution static synchronous compensator (DSTATCOM); distribution transformer; passivity based control (PBC); winding taps

Indexed keywords

ELECTRIC CURRENT REGULATORS; ELECTRIC POWER UTILIZATION; ELECTRIC TRANSFORMERS; MATLAB; POWER CONVERTERS; REACTIVE POWER; THALLIUM COMPOUNDS; TRANSFORMER WINDINGS; WINDING;

EID: 85038908632     PISSN: 08858993     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPEL.2017.2698207     Document Type: Article
Times cited : (39)

References (23)
  • 1
    • 84930193788 scopus 로고    scopus 로고
    • A review of distribution static compensator
    • O. P. Mahela and A. G. Shaik, "A review of distribution static compensator," Renew. Sustain. Energy Rev., vol. 50, pp. 531-546, 2015.
    • (2015) Renew. Sustain. Energy Rev. , vol.50 , pp. 531-546
    • Mahela, O.P.1    Shaik, A.G.2
  • 3
    • 84877766626 scopus 로고    scopus 로고
    • Cascaded multilevel converter-based transmission STATCOM: System design methodology and development of a 12 kV ±12 MVAr power stage
    • Nov.
    • B. Gultekin and M. Ermis, "Cascaded multilevel converter-based transmission STATCOM: System design methodology and development of a 12 kV ±12 MVAr power stage," IEEE Trans. Power Electron., vol. 28, no. 11, pp. 4930-4950, Nov. 2013.
    • (2013) IEEE Trans. Power Electron , vol.28 , Issue.11 , pp. 4930-4950
    • Gultekin, B.1    Ermis, M.2
  • 4
    • 84906213755 scopus 로고    scopus 로고
    • Elimination of coupling transformer core saturation in cascaded multilevel converter-based T-STATCOM systems
    • Dec.
    • C. O. Gercek and M. Ermis, "Elimination of coupling transformer core saturation in cascaded multilevel converter-based T-STATCOM systems," IEEE Trans. Power Electron., vol. 29, no. 12, pp. 6796-6809, Dec. 2014.
    • (2014) IEEE Trans. Power Electron , vol.29 , Issue.12 , pp. 6796-6809
    • Gercek, C.O.1    Ermis, M.2
  • 5
    • 84859033248 scopus 로고    scopus 로고
    • A transformerless D-STATCOM based on a multivoltage cascade converter requiring no dc sources
    • Jun.
    • K. Sano and M. Takasaki, "A transformerless D-STATCOM based on a multivoltage cascade converter requiring no dc sources," IEEE Trans. Power Electron., vol. 27, no. 6, pp. 2783-2795, Jun. 2012.
    • (2012) IEEE Trans. Power Electron , vol.27 , Issue.6 , pp. 2783-2795
    • Sano, K.1    Takasaki, M.2
  • 6
    • 53349101730 scopus 로고    scopus 로고
    • A transformerless energy storage system based on a cascade multilevel PWM converter with star configuration
    • Sep./Oct.
    • L. Maharjan, S. Inoue, and H. Akagi, "A transformerless energy storage system based on a cascade multilevel PWM converter with star configuration," IEEE Trans. Ind. Appl., vol. 44, no. 5, pp. 1621-1630, Sep./Oct. 2008.
    • (2008) IEEE Trans. Ind. Appl. , vol.44 , Issue.5 , pp. 1621-1630
    • Maharjan, L.1    Inoue, S.2    Akagi, H.3
  • 7
    • 84855167160 scopus 로고    scopus 로고
    • A transformerless medium-voltage STATCOM topology based on extended modular multilevel converters
    • May
    • H. P. Mohammadi and M. T. Bina, "A transformerless medium-voltage STATCOM topology based on extended modular multilevel converters," IEEE Trans. Power Electron., vol. 26, no. 5, pp. 1534-1545, May 2011.
    • (2011) IEEE Trans. Power Electron , vol.26 , Issue.5 , pp. 1534-1545
    • Mohammadi, H.P.1    Bina, M.T.2
  • 8
    • 34547885037 scopus 로고    scopus 로고
    • Control and performance of a transformerless cascade PWM STATCOM with star configuration
    • Jul./Aug.
    • H. Akagi, S. Inoue, and T. Yoshii, "Control and performance of a transformerless cascade PWM STATCOM with star configuration," IEEE Trans. Ind. Appl., vol. 43, no. 4, pp. 1041-1049, Jul./Aug. 2007.
    • (2007) IEEE Trans. Ind. Appl. , vol.43 , Issue.4 , pp. 1041-1049
    • Akagi, H.1    Inoue, S.2    Yoshii, T.3
  • 9
    • 68449100492 scopus 로고    scopus 로고
    • A new control technique for three-phase shunt hybrid power filter
    • Aug.
    • S. Rahmani, A. Hamadi, N. Mendalek, and K. Al-Haddad, "A new control technique for three-phase shunt hybrid power filter," IEEE Trans. Ind. Electron., vol. 56, no. 8, pp. 2904-2915, Aug. 2009.
    • (2009) IEEE Trans. Ind. Electron , vol.56 , Issue.8 , pp. 2904-2915
    • Rahmani, S.1    Hamadi, A.2    Mendalek, N.3    Al-Haddad, K.4
  • 10
    • 84856887545 scopus 로고    scopus 로고
    • A DSTATCOM topology with reduced dc-link voltage rating for load compensation with nonstiff source
    • Mar.
    • S. B. Karanki, N. Geddada, M. K. Mishra, and B. K. Kumar, "A DSTATCOM topology with reduced dc-link voltage rating for load compensation with nonstiff source," IEEE Trans. Power Electron., vol. 27, no. 3, pp. 1201-1211, Mar. 2012.
    • (2012) IEEE Trans. Power Electron , vol.27 , Issue.3 , pp. 1201-1211
    • Karanki, S.B.1    Geddada, N.2    Mishra, M.K.3    Kumar, B.K.4
  • 11
    • 84969822741 scopus 로고    scopus 로고
    • A hybrid-STATCOM with wide compensation range and low DC-link voltage
    • Jun.
    • L. Wang, C. S. Lam, and M. C. Wong, "A hybrid-STATCOM with wide compensation range and low DC-link voltage," IEEE Trans. Ind. Electron., vol. 63, no. 6, pp. 3333-3343, Jun. 2016.
    • (2016) IEEE Trans. Ind. Electron , vol.63 , Issue.6 , pp. 3333-3343
    • Wang, L.1    Lam, C.S.2    Wong, M.C.3
  • 12
    • 84887075620 scopus 로고    scopus 로고
    • A combination of shunt hybrid power filter and thyristor-controlled reactor for power quality
    • May
    • S. Rahmani, A. Hamadi, K. Al-Haddad, and L. A. Dessaint, "A combination of shunt hybrid power filter and thyristor-controlled reactor for power quality," IEEE Trans. Ind. Electron., vol. 61, no. 5, pp. 2152-2164, May 2014.
    • (2014) IEEE Trans. Ind. Electron , vol.61 , Issue.5 , pp. 2152-2164
    • Rahmani, S.1    Hamadi, A.2    Al-Haddad, K.3    Dessaint, L.A.4
  • 13
    • 84907483835 scopus 로고    scopus 로고
    • An improved hybrid DSTATCOM topology to compensate reactive and nonlinear loads
    • Dec.
    • C. Kumar and M. K. Mishra. "An improved hybrid DSTATCOM topology to compensate reactive and nonlinear loads," IEEE Trans. Ind. Electron., vol. 61, no. 12, pp. 6517-6527, Dec. 2014.
    • (2014) IEEE Trans. Ind. Electron , vol.61 , Issue.12 , pp. 6517-6527
    • Kumar, C.1    Mishra, M.K.2
  • 14
    • 84963788764 scopus 로고    scopus 로고
    • A Y-D multifunction balance transformer-based power quality control system for single-phase power supply system
    • Mar./Apr.
    • S. Hu et al., "A Y-D multifunction balance transformer-based power quality control system for single-phase power supply system," IEEE Trans. Ind. Appl., vol. 52, no. 2, pp. 1270-1279, Mar./Apr. 2016.
    • (2016) IEEE Trans. Ind. Appl. , vol.52 , Issue.2 , pp. 1270-1279
    • Hu, S.1
  • 15
    • 84941585066 scopus 로고    scopus 로고
    • A new integrated hybrid power quality control system for electrical railway
    • Oct.
    • S. J. Hu et al., "A new integrated hybrid power quality control system for electrical railway," IEEE Trans. Ind. Electron., vol. 62, no. 10, pp. 6222-6232, Oct. 2015.
    • (2015) IEEE Trans. Ind. Electron , vol.62 , Issue.10 , pp. 6222-6232
    • Hu, S.J.1
  • 16
    • 84875640760 scopus 로고    scopus 로고
    • A novel compensation technology of static synchronous compensator integrated with distribution transformer
    • Apr.
    • C. Wang, X. Yin, Z. Zhang, and M. Wen, "A novel compensation technology of static synchronous compensator integrated with distribution transformer," IEEE Trans. Power Del., vol. 28, no. 2, pp. 1032-1039, Apr. 2013.
    • (2013) IEEE Trans. Power Del. , vol.28 , Issue.2 , pp. 1032-1039
    • Wang, C.1    Yin, X.2    Zhang, Z.3    Wen, M.4
  • 18
    • 84872981529 scopus 로고    scopus 로고
    • Eliminating dc current injection in current-transformer-sensed STATCOMs
    • Aug.
    • Y. Shi, B. Liu, and S. Duan, "Eliminating dc current injection in current-transformer-sensed STATCOMs," IEEE Trans. Power Electron., vol. 28, no. 8, pp. 3760-3767, Aug. 2013.
    • (2013) IEEE Trans. Power Electron , vol.28 , Issue.8 , pp. 3760-3767
    • Shi, Y.1    Liu, B.2    Duan, S.3
  • 19
    • 84908231872 scopus 로고    scopus 로고
    • A novel control method for transformerless H-bridge cascaded STATCOM with star configuration
    • Mar.
    • R. Xu et al., "A novel control method for transformerless H-bridge cascaded STATCOM with star configuration," IEEE Trans. Power Electron., vol. 30, no. 3, pp. 1189-1202, Mar. 2015.
    • (2015) IEEE Trans. Power Electron , vol.30 , Issue.3 , pp. 1189-1202
    • Xu, R.1
  • 20
    • 84943396107 scopus 로고    scopus 로고
    • Passivity-based control with nonlinear damping for type 2 STATCOMsystems
    • Jul.
    • Y. Gui, W. Kim, and C. C. Chung, "Passivity-based control with nonlinear damping for type 2 STATCOMsystems," IEEE Trans. Power Syst., vol. 31, no. 4, pp. 2824-2833, Jul. 2016.
    • (2016) IEEE Trans. Power Syst. , vol.31 , Issue.4 , pp. 2824-2833
    • Gui, Y.1    Kim, W.2    Chung, C.C.3
  • 21
    • 4043089778 scopus 로고    scopus 로고
    • Lagrangian modeling and passivity-based control of threephase AC/DC voltage-source converters
    • Aug.
    • T. S. Lee, "Lagrangian modeling and passivity-based control of threephase AC/DC voltage-source converters," IEEE Trans. Ind. Electron., vol. 51, no. 4, pp. 892-902, Aug. 2004.
    • (2004) IEEE Trans. Ind. Electron , vol.51 , Issue.4 , pp. 892-902
    • Lee, T.S.1
  • 22
    • 84938096212 scopus 로고    scopus 로고
    • Improved passivity-based control method and its robustness analysis for single-phase uninterruptible power supply inverters
    • H. Komurcugil, "Improved passivity-based control method and its robustness analysis for single-phase uninterruptible power supply inverters," IET Power Electron., vol. 8, no. 8, pp. 1558-1570, 2015.
    • (2015) IET Power Electron , vol.8 , Issue.8 , pp. 1558-1570
    • Komurcugil, H.1
  • 23
    • 0141917752 scopus 로고    scopus 로고
    • Load compensating DSTATCOM in weak AC systems
    • Oct.
    • A. Ghosh and G. Ledwich, "Load compensating DSTATCOM in weak AC systems," IEEE Trans. Power Del., vol. 18, no. 4, pp. 1302-1309, Oct. 2003.
    • (2003) IEEE Trans. Power Del. , vol.18 , Issue.4 , pp. 1302-1309
    • Ghosh, A.1    Ledwich, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.