메뉴 건너뛰기




Volumn 1999-April, Issue , 1999, Pages

Minimizing localized corrosion via new chemical treatments and performance based treatment optimization and control

Author keywords

Carbon steel; Cooling water; Corrosion monitoring; Crevice corrosion; Heat exchanger; Hydrocarbon leak detection; Hydrogen permeation; Inhibitor; Localized corrosion; MIC; Mild steel; On line measurement; Pitting; Service life; Treatment optimization

Indexed keywords

APPLICATION PROGRAMS; CARBON STEEL; CHEMICAL OPERATIONS; COOLING; COOLING WATER; CORROSION INHIBITORS; CORROSION RATE; CREVICE CORROSION; HEAT EXCHANGERS; LEAK DETECTION; PITTING; REAL TIME SYSTEMS; SAFETY FACTOR; SERVICE LIFE; STEEL CORROSION; WATER TREATMENT;

EID: 85036693907     PISSN: 03614409     EISSN: None     Source Type: Book Series    
DOI: None     Document Type: Conference Paper
Times cited : (11)

References (21)
  • 1
    • 0012782004 scopus 로고    scopus 로고
    • Real time localized corrosion monitoring in refinery cooling water systems
    • NACE, Houston, TX
    • B. Yang, "Real Time Localized Corrosion Monitoring in Refinery Cooling Water Systems," CORROSION/98, Paper No. 595, NACE, Houston, TX (1998).
    • (1998) CORROSION/98, Paper No. 595
    • Yang, B.1
  • 4
    • 84902934803 scopus 로고    scopus 로고
    • Edited by the Task Group for Heat Exchanger Residual Life Prediction, Corrosion and Anticorrosion Subcommittee, Japanese Material Society, September
    • Heat Exchanger Management and Residual Life Prediction. Edited by the Task Group for Heat Exchanger Residual Life Prediction, Corrosion and Anticorrosion Subcommittee, Japanese Material Society, September 1996.
    • (1996) Heat Exchanger Management and Residual Life Prediction
  • 6
    • 85046810323 scopus 로고
    • In-plant test heat exchanger corrosion and fouling evaluation of several NonChromate inhibitors
    • NACE, Houston, TX
    • J. A. Gesick, "In-Plant Test Heat Exchanger Corrosion and Fouling Evaluation of Several NonChromate Inhibitors," CORROSION/73, Paper No. 88, NACE, Houston, TX (1973).
    • (1973) CORROSION/73, Paper No. 88
    • Gesick, J.A.1
  • 10
    • 0031102685 scopus 로고    scopus 로고
    • Statistical analysis of pitting corrosion in condenser tubes
    • ASTM STP 1300, R. M. Kain and W. T. Young, Eds., ASTM
    • J. P. Ault and G. A. Gehring, Jr., "Statistical Analysis of Pitting Corrosion in Condenser Tubes," in Corrosion Testing in Natural Waters: Second Volume, p. 109, ASTM STP 1300, R. M. Kain and W. T. Young, Eds., ASTM (1997).
    • (1997) Corrosion Testing in Natural Waters: Second Volume , pp. 109
    • Ault, J.P.1    Gehring, G.A.2
  • 12
    • 24044500558 scopus 로고
    • Localized corrosion monitoring in cooling water systems
    • NACE, Houston, TX
    • B. Yang, "Localized Corrosion Monitoring in Cooling Water Systems," CORROSION/95, Paper No. 541, NACE, Houston, TX (1995).
    • (1995) CORROSION/95, Paper No. 541
    • Yang, B.1
  • 14
    • 85046775024 scopus 로고
    • Studies of localized corrosion using an occluded cell device
    • NACE, Houston, TX
    • S. H. Shim and D. A. Johnson, "Studies of Localized Corrosion Using An Occluded Cell Device," CORROSION/91, Paper No. 86, NACE, Houston, TX (1991).
    • (1991) CORROSION/91, Paper No. 86
    • Shim, S.H.1    Johnson, D.A.2
  • 16
    • 0016598786 scopus 로고
    • Dangerous inhibitors and pitting: Some practical aspects of cause, measurement and prevention
    • Ann. Univ. Ferrara, N. S. Sez., Ferrara, Italy
    • C. C. Nathan and C. della Rocca, "Dangerous Inhibitors and Pitting: Some Practical Aspects of Cause, Measurement and Prevention," in Proc. 4th Eur. Symp. Corros. Inhibitors, p.294, Ann. Univ. Ferrara, N. S. Sez., Ferrara, Italy (1975).
    • (1975) Proc. 4th Eur. Symp. Corros. Inhibitors , pp. 294
    • Nathan, C.C.1    Della Rocca, C.2
  • 17
    • 0001161786 scopus 로고
    • B. Yang, Corrosion, Vol. 51, 153 (1995).
    • (1995) Corrosion , vol.51 , pp. 153
    • Yang, B.1
  • 18
    • 0003582445 scopus 로고
    • A novel method for on-line determination of underdeposit corrosion rates in cooling water systems
    • NACE, Houston, TX
    • B. Yang, "A Novel Method for On-line Determination of Underdeposit Corrosion Rates in Cooling Water Systems," CORROSION/94, Paper No. 335, NACE, Houston, TX (1994).
    • (1994) CORROSION/94, Paper No. 335
    • Yang, B.1
  • 20
    • 34248180916 scopus 로고    scopus 로고
    • A new localized corrosion monitoring technique for the evaluation of oilfield inhibitors
    • NACE, Houston, TX
    • S. L. Fu, A. M. Griffin, J. G. Garcia, Jr, and B. Yang, "A New Localized Corrosion Monitoring Technique for the Evaluation of Oilfield Inhibitors," CORROSION/96, Paper No. 346, NACE, Houston, TX (1996).
    • (1996) CORROSION/96, Paper No. 346
    • Fu, S.L.1    Griffin, A.M.2    Garcia, J.G.3    Yang, B.4
  • 21
    • 85046758840 scopus 로고    scopus 로고
    • Hydrogen permeation and its inhibition in iron oxide cleaning solutions
    • NACE, Houston, TX
    • B. Yang, H. Zheng, and D. A. Johnson, "Hydrogen Permeation and Its Inhibition in Iron Oxide Cleaning Solutions," CORROSION/97, Paper No. 271, NACE, Houston, TX (1997).
    • (1997) CORROSION/97, Paper No. 271
    • Yang, B.1    Zheng, H.2    Johnson, D.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.