-
1
-
-
8944256349
-
New methods for calculating metabolic rate with special reference to protein metabolism
-
Weir JBD. New methods for calculating metabolic rate with special reference to protein metabolism. J Physiol. 1949;109(1-2):1-9.
-
(1949)
J Physiol
, vol.109
, Issue.1-2
, pp. 1-9
-
-
Weir, J.B.D.1
-
3
-
-
0024423390
-
Measurement of gas exchange in intensive care: laboratory and clinical validation of a new device
-
Takala J, Keinanen O, Vaisanen P, Kari A. Measurement of gas exchange in intensive care: laboratory and clinical validation of a new device. Crit Care Med. 1989;17:1041-1047.
-
(1989)
Crit Care Med
, vol.17
, pp. 1041-1047
-
-
Takala, J.1
Keinanen, O.2
Vaisanen, P.3
Kari, A.4
-
4
-
-
0043069928
-
Assessment of resting energy expenditure in mechanically ventilated patients
-
Faisy C, Guerot E, Diehl J-LL, Labrousse J, Fagon J-YY. Assessment of resting energy expenditure in mechanically ventilated patients. Am J Clin Nutr. 2003;78:241-249.
-
(2003)
Am J Clin Nutr
, vol.78
, pp. 241-249
-
-
Faisy, C.1
Guerot, E.2
Diehl, J.-L.L.3
Labrousse, J.4
Fagon, J.-Y.Y.5
-
5
-
-
84872604749
-
Indirect calorimetry in mechanically ventilated patients: a systematic comparison of three instruments
-
Sundström M, Tjäder I, Rooyackers O, Wernerman J. Indirect calorimetry in mechanically ventilated patients: a systematic comparison of three instruments. Clin Nutr. 2013;32(1):118-121.
-
(2013)
Clin Nutr
, vol.32
, Issue.1
, pp. 118-121
-
-
Sundström, M.1
Tjäder, I.2
Rooyackers, O.3
Wernerman, J.4
-
6
-
-
84921438351
-
Evaluation of three indirect calorimetry devices in mechanically ventilated patients: which device compares best with the Deltatrac II(®)? A prospective observational study
-
Graf S, Karsegard VL, Viatte V. Evaluation of three indirect calorimetry devices in mechanically ventilated patients: which device compares best with the Deltatrac II(®)? A prospective observational study. Clin Nutr. 2015;34(1):60-65.
-
(2015)
Clin Nutr
, vol.34
, Issue.1
, pp. 60-65
-
-
Graf, S.1
Karsegard, V.L.2
Viatte, V.3
-
7
-
-
0028914731
-
Clinical validation of the Deltatrac monitoring system in mechanically ventilated patients
-
Tissot S, Delafosse B, Bertrand O, Bouffard Y, Viale JP, Annat G. Clinical validation of the Deltatrac monitoring system in mechanically ventilated patients. Intensive Care Med. 1995;21(2):149-153.
-
(1995)
Intensive Care Med
, vol.21
, Issue.2
, pp. 149-153
-
-
Tissot, S.1
Delafosse, B.2
Bertrand, O.3
Bouffard, Y.4
Viale, J.P.5
Annat, G.6
-
8
-
-
0025609398
-
Volume calibration of various gasmeters using a modified Tissot spirometer
-
Wenzel C, Golka K, Klimmer F, Rutenfranz J, Wenzel HG. Volume calibration of various gasmeters using a modified Tissot spirometer. Eur J Appl Physiol Occup Physiol. 1990;61(5-6):380-385.
-
(1990)
Eur J Appl Physiol Occup Physiol
, vol.61
, Issue.5-6
, pp. 380-385
-
-
Wenzel, C.1
Golka, K.2
Klimmer, F.3
Rutenfranz, J.4
Wenzel, H.G.5
-
9
-
-
0025322199
-
A respiratory gas exchange simulator for routine calibration in metabolic studies
-
Huszczuk A, Whipp BJ, Wasserman K. A respiratory gas exchange simulator for routine calibration in metabolic studies. Eur Respir J. 1990;3(4):465-468.
-
(1990)
Eur Respir J
, vol.3
, Issue.4
, pp. 465-468
-
-
Huszczuk, A.1
Whipp, B.J.2
Wasserman, K.3
-
10
-
-
33745586818
-
Best practice methods to apply to measurement of resting metabolic rate in adults: a systematic review
-
Compher C, Frankenfield D, Keim N, Roth-Yousey L. Best practice methods to apply to measurement of resting metabolic rate in adults: a systematic review. J Am Diet Assoc. 2006;106(6):881-903.
-
(2006)
J Am Diet Assoc
, vol.106
, Issue.6
, pp. 881-903
-
-
Compher, C.1
Frankenfield, D.2
Keim, N.3
Roth-Yousey, L.4
-
12
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307-310.
-
(1986)
Lancet
, vol.1
, Issue.8476
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
13
-
-
0028227989
-
A modified photo- and magnetoacoustic multigas analyzer applied in gas exchange measurements
-
Clemensen P, Christensen P, Norsk P, Grønlund J. A modified photo- and magnetoacoustic multigas analyzer applied in gas exchange measurements. J Appl Physiol. 1994;76(6):2832-2839.
-
(1994)
J Appl Physiol
, vol.76
, Issue.6
, pp. 2832-2839
-
-
Clemensen, P.1
Christensen, P.2
Norsk, P.3
Grønlund, J.4
-
14
-
-
0023110619
-
Indirect calorimetry in the mechanically ventilated patient
-
Levinson MR, Groeger JS, Miodownik S, Ray C, Brennan MF. Indirect calorimetry in the mechanically ventilated patient. Crit Care Med. 1987;15(2):144-147.
-
(1987)
Crit Care Med
, vol.15
, Issue.2
, pp. 144-147
-
-
Levinson, M.R.1
Groeger, J.S.2
Miodownik, S.3
Ray, C.4
Brennan, M.F.5
-
15
-
-
33751112509
-
Comparison of metabolic monitors in critically ill, ventilated patients
-
Singer P, Pogrebetsky I, Attal-Singer J, Cohen J. Comparison of metabolic monitors in critically ill, ventilated patients. Nutrition. 2006;22(11-12):1077-1086.
-
(2006)
Nutrition
, vol.22
, Issue.11-12
, pp. 1077-1086
-
-
Singer, P.1
Pogrebetsky, I.2
Attal-Singer, J.3
Cohen, J.4
-
16
-
-
84922567867
-
Metabolic monitoring in the intensive care unit: a comparison of the Medgraphics Ultima, Deltatrac II, and Douglas bag collection methods
-
Black C, Grocott MPW, Singer M. Metabolic monitoring in the intensive care unit: a comparison of the Medgraphics Ultima, Deltatrac II, and Douglas bag collection methods. Br J Anaesth. 2015;114(2):261-268.
-
(2015)
Br J Anaesth
, vol.114
, Issue.2
, pp. 261-268
-
-
Black, C.1
Grocott, M.P.W.2
Singer, M.3
-
17
-
-
22944476109
-
Negative impact of hypocaloric feeding and energy balance on clinical outcome in ICU patients
-
Villet S, Chiolero RL, Bollmann MD. Negative impact of hypocaloric feeding and energy balance on clinical outcome in ICU patients. Clin Nutr. 2005;24(4):502-509.
-
(2005)
Clin Nutr
, vol.24
, Issue.4
, pp. 502-509
-
-
Villet, S.1
Chiolero, R.L.2
Bollmann, M.D.3
-
18
-
-
33144485937
-
Computerized energy balance and complications in critically ill patients: an observational study
-
Dvir D, Cohen J, Singer P. Computerized energy balance and complications in critically ill patients: an observational study. Clin Nutr. 2006;25(1):37-44.
-
(2006)
Clin Nutr
, vol.25
, Issue.1
, pp. 37-44
-
-
Dvir, D.1
Cohen, J.2
Singer, P.3
-
19
-
-
79953825136
-
The Tight Calorie Control Study (TICACOS): a prospective, randomized, controlled pilot study of nutritional support in critically ill patients
-
Singer P, Anbar R, Cohen J. The Tight Calorie Control Study (TICACOS): a prospective, randomized, controlled pilot study of nutritional support in critically ill patients. Intensive Care Med. 2011;37(4):601-609.
-
(2011)
Intensive Care Med
, vol.37
, Issue.4
, pp. 601-609
-
-
Singer, P.1
Anbar, R.2
Cohen, J.3
-
20
-
-
84873108218
-
Optimisation of energy provision with supplemental parenteral nutrition in critically ill patients: a randomised controlled clinical trial
-
Heidegger CP, Berger MM, Graf S. Optimisation of energy provision with supplemental parenteral nutrition in critically ill patients: a randomised controlled clinical trial. Lancet. 2013;381(9864):385-393.
-
(2013)
Lancet
, vol.381
, Issue.9864
, pp. 385-393
-
-
Heidegger, C.P.1
Berger, M.M.2
Graf, S.3
-
21
-
-
34548118410
-
Prediction of resting metabolic rate in critically ill adult patients: results of a systematic review of the evidence
-
Frankenfield D, Hise M, Malone A, Russell M, Gradwell E, Compher C. Prediction of resting metabolic rate in critically ill adult patients: results of a systematic review of the evidence. J Am Diet Assoc. 2007;107(9):1552-1561.
-
(2007)
J Am Diet Assoc
, vol.107
, Issue.9
, pp. 1552-1561
-
-
Frankenfield, D.1
Hise, M.2
Malone, A.3
Russell, M.4
Gradwell, E.5
Compher, C.6
-
22
-
-
84991269790
-
Estimation of energy requirements for mechanically ventilated, critically ill patients using nutritional status
-
Kan MN, Chang HH, Sheu WF, Cheng CH, Lee BJ, Huang YC. Estimation of energy requirements for mechanically ventilated, critically ill patients using nutritional status. Crit Care. 2003;7(5):R108-R115.
-
(2003)
Crit Care
, vol.7
, Issue.5
, pp. R108-R115
-
-
Kan, M.N.1
Chang, H.H.2
Sheu, W.F.3
Cheng, C.H.4
Lee, B.J.5
Huang, Y.C.6
-
23
-
-
84883559315
-
Introducing a new generation indirect calorimeter for estimating energy requirements in adult intensive care unit patients: feasibility, practical considerations, and comparison with a mathematical equation
-
De Waele E, Spapen H, Honoré PM. Introducing a new generation indirect calorimeter for estimating energy requirements in adult intensive care unit patients: feasibility, practical considerations, and comparison with a mathematical equation. J Crit Care. 2013;28(5):884.e1-e6.
-
(2013)
J Crit Care
, vol.28
, Issue.5
, pp. e1-e6
-
-
De Waele, E.1
Spapen, H.2
Honoré, P.M.3
-
24
-
-
84861195963
-
A comparison of predictive equations of energy expenditure and measured energy expenditure in critically ill patients
-
Kross EK, Sena M, Schmidt K, Stapleton RD. A comparison of predictive equations of energy expenditure and measured energy expenditure in critically ill patients. J Crit Care. 2012;27:312-321.
-
(2012)
J Crit Care
, vol.27
, pp. 312-321
-
-
Kross, E.K.1
Sena, M.2
Schmidt, K.3
Stapleton, R.D.4
|