메뉴 건너뛰기




Volumn 2001-March, Issue , 2001, Pages

Material selection for separation, transportation and disposal of CO2

Author keywords

[No Author keywords available]

Indexed keywords

CARBON STEEL; CORROSION RATE; ENHANCED RECOVERY; MATERIALS HANDLING; OIL WELL FLOODING; STEEL CORROSION;

EID: 85034453984     PISSN: 03614409     EISSN: None     Source Type: Book Series    
DOI: None     Document Type: Conference Paper
Times cited : (52)

References (23)
  • 3
    • 84860913051 scopus 로고
    • 2 pipeline-compression system sacroc unit, scurry county, Texas
    • Houston, TX: SPE Intemational
    • J. M. West, "Design and Operation of a Supercritical CO2 Pipeline-Compression System SACROC Unit, Scurry County, Texas" SPE Paper No. 4804 (Houston, TX: SPE Intemational, 1974).
    • (1974) SPE Paper 4804
    • West, J.M.1
  • 5
    • 0029770169 scopus 로고    scopus 로고
    • 2 injection into a shallow underground aquifer
    • Houston, TX: SPE International
    • A. Baklid, R. Korb01, G. Owren, "Sleipner Vest CO2 Disposal, CO2 Injection into a Shallow Underground Aquifer", SPE Paper No. 36600 (Houston, TX: SPE International, 1996)
    • (1996) SPE Paper 36600
    • Baklid, A.1    Korb, R.2    Owren, G.3
  • 7
    • 85046782901 scopus 로고
    • 2-5 31 mol% methane) along the three-phase and Supercritical Conditions
    • Houston, TX: SPE International
    • K. Y. Song, "Water Content of a Near-Specification CO2-Rich Gas Mixture (CO2-5. 31 mol% Methane) Along the Three-Phase and Supercritical Conditions" SPE Paper No. 18583 (Houston, TX: SPE International, 1988)
    • (1988) SPE Paper 18583
    • Song, K.Y.1
  • 12
  • 14
    • 84860913051 scopus 로고
    • 2 pipeline-compression system sacroc unit, scurry county, Texas
    • Houston, TX: SPE International
    • J. M. West, "Design and Operation of a Supercritical CO2 Pipeline-Compression System Sacroc Unit, Scurry County, Texas", SPE Paper No. 4804 (Houston, TX: SPE International, 1974)
    • (1974) SPE Paper 4804
    • West, J.M.1
  • 16
    • 0021862159 scopus 로고
    • 2 pipeline: Description and 12 years of operation
    • New York, NY: ASME
    • T. E. Gill, "Canyon Reef Carders, inc. CO2 Pipeline: Description and 12 Years of Operation" ASME Energy-Source Technol. Conf. Pipeline Eng. Symp.: p. 59, (New York, NY: ASME, 1985)
    • (1985) ASME Energy-Source Technol. Conf. Pipeline Eng. Symp , pp. 59
    • Gill, T.E.1
  • 18
    • 33646224139 scopus 로고
    • 2 corrosion of steel effect on scale morphology and chemical composition, Corrosion Rate, Pitting Susceptibility and Inhibitor Performance
    • Florence, Italy
    • Schmitt, G., Krieck-Defrain, M. Proc. "pH-Static Experiments in high Pressure CO2 Corrosion of Steel. Effect on Scale Morphology and Chemical Composition, Corrosion Rate, Pitting Susceptibility and Inhibitor Performance" 1 lth International Corrosion Congress, Paper No. 480, Vol. 5, p. 529, (Florence, Italy: 1990)
    • (1990) 1 Lth International Corrosion Congress, Paper No. 480 , vol.5 , pp. 529
    • Schmitt, G.1    Proc, K.M.2
  • 19
    • 0017321539 scopus 로고
    • 2 project, sacroc unit
    • Houston, TX: SPE International
    • L. E. Newton, R. A. Mcclay, "Corrosion and Operational Problems, CO2 Project, Sacroc Unit" SPE Paper No. 6391 (Houston, TX: SPE International, 1977)
    • (1977) SPE Paper 6391
    • Newton, L.E.1    Mcclay, R.A.2
  • 21
    • 84860946663 scopus 로고    scopus 로고
    • NORSOK standard M-506, 1 June Oslo, Norway: Norwegian Technology Center (NTS)
    • NORSOK standard M-506, "CO2 Corrosion Rate Calculation Model", Rev. 1, June 1998, (Oslo, Norway: Norwegian Technology Center (NTS), (www.nts. no/norsok))
    • (1998) 2 Corrosion Rate Calculation Model Rev


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.