Comparison of the therapeutic effects of bubble CPAP and ventilator CPAP on respiratory distress syndrome in premature neonates

Author keywords

Bubble CPAP; Neonate; Oxygen therapy; Respiratory distress syndrome

Indexed keywords

APGAR SCORE; ARTICLE; ARTIFICIAL VENTILATION; BIRTH WEIGHT; BUBBLE CONTINUOUS POSITIVE AIRWAY PRESSURE; CLINICAL EFFECTIVENESS; COMPARATIVE STUDY; CONTROLLED STUDY; CPAP DEVICE; FEMALE; GESTATIONAL AGE; HOSPITAL ADMISSION; HUMAN; IRAN; MAJOR CLINICAL STUDY; MALE; NEONATAL INTENSIVE CARE UNIT; NEWBORN; OXYGEN THERAPY; POSITIVE END EXPIRATORY PRESSURE; PREMATURITY; RANDOMIZED CONTROLLED TRIAL; RESPIRATORY DISTRESS SYNDROME; TREATMENT DURATION; VENTILATOR CONTINUOUS POSITIVE AIRWAY PRESSURE;

EID: 85029748371     PISSN: 22517510     EISSN: 23222158     Source Type: Journal    
DOI: 10.22038/ijn.2017.18835.1215     Document Type: Article
Times cited : (3)

References (15)
  • 2
    • 80054774239 scopus 로고    scopus 로고
    • Prevalence and risk factors for low birth weight in Yazd, Iran
    • Golestan M, Akhavan Karbasi S, Fallah R. Prevalence and risk factors for low birth weight in Yazd, Iran. Singapore Med J. 2011; 52(10):730-3.
    • (2011) Singapore Med J , vol.52 , Issue.10 , pp. 730-733
    • Golestan, M.1    S, A.K.2    Fallah, R.3
  • 3
    • 65749091418 scopus 로고    scopus 로고
    • Neonatal mortality oflow birth weight infants in Yazd, Iran
    • Golestan M, Fallah R, Akhavan Karbasi S. Neonatal mortality oflow birth weight infants in Yazd, Iran. Int J Reprod Biomed. 2008; 6(4):205–8.
    • (2008) Int J Reprod Biomed , vol.6 , Issue.4 , pp. 205-208
    • Golestan, M.1    Fallah, R.2    S, A.K.3
  • 4
    • 84874771243 scopus 로고    scopus 로고
    • The high-risk infant
    • Kliegman RM Behrman RE Jenson HB Stanton BM editors 20th Philadelphia Elsevier Health Sciences
    • Waldermar A. The high-risk infant. In: Kliegman RM, Behrman RE, Jenson HB, Stanton BM, editors. Nelson textbook of pediatrics. 20th ed. Philadelphia: Elsevier Health Sciences; 2011. P. 818-20.
    • (2011) Nelson Textbook of Pediatrics , pp. 818-820
    • Waldermar, A.1
  • 5
    • 4243220684 scopus 로고    scopus 로고
    • Respiratory distress syndrome
    • Kliegman RM Behrman RE Jenson HB Stanton BM editors 20th Philadelphia Elsevier Health Sciences
    • Waldemar A. Respiratory distress syndrome. In: Kliegman RM, Behrman RE, Jenson HB, Stanton BM, editors. Nelson textbook of pediatrics. 20th ed. Philadelphia: Elsevier Health Sciences; 2011. P. 850-8.
    • (2011) Nelson Textbook of Pediatrics , pp. 850-858
    • Waldemar, A.1
  • 6
    • 82455182339 scopus 로고    scopus 로고
    • Noninvasive respiratory support
    • Goldsmith JP Karotkin EH editors 5th Philadelphia Saunders
    • Thomas E, Sherry E. Noninvasive respiratory support. In: Goldsmith JP, Karotkin EH, editors. Assisted ventilation of the neonate. 5th ed. Philadelphia: Saunders; 2011. P. 140-63.
    • (2011) Assisted Ventilation of The Neonate , pp. 140-163
    • Thomas, E.1    Sherry, E.2
  • 7
    • 77954934918 scopus 로고    scopus 로고
    • A pilot study of comparison of BCPAP vs. VCPAP in preterm infants with early onset respiratory distress
    • Tagare A, Kadam S, Vaidya U, Pandit A, Patole S. A pilot study of comparison of BCPAP vs. VCPAP in preterm infants with early onset respiratory distress. J Trop Pediatr. 2010; 56(3):191-4.
    • (2010) J Trop Pediatr , vol.56 , Issue.3 , pp. 191-194
    • Tagare, A.1    Kadam, S.2    Vaidya, U.3    Pandit, A.4    Patole, S.5
  • 8
    • 79959257596 scopus 로고    scopus 로고
    • Bubble-CPAP vs. Ventilatory-CPAP in preterm infants with respiratory distress
    • Bahman-Bijari B, Malekiyan A, Niknafs P, Baneshi MR. Bubble-CPAP vs. Ventilatory-CPAP in preterm infants with respiratory distress. Iran J Pediatr. 2011; 21(2):151-8.
    • (2011) Iran J Pediatr , vol.21 , Issue.2 , pp. 151-158
    • Bahman-Bijari, B.1    Malekiyan, A.2    Niknafs, P.3    Baneshi, M.R.4
  • 9
    • 78650792289 scopus 로고    scopus 로고
    • Bubble and ventilator-derived nasal continuous positive airway pressure in premature infants: Work of breathing and gas exchange
    • Courtney SE, Kahn DJ, Singh R, Habib RH. Bubble and ventilator-derived nasal continuous positive airway pressure in premature infants: work of breathing and gas exchange. J Perinatol. 2011, 3(1):44-50.
    • (2011) J Perinatol , vol.3 , Issue.1 , pp. 44-50
    • Courtney, S.E.1    Kahn, D.J.2    Singh, R.3    Habib, R.H.4
  • 10
    • 34247145049 scopus 로고    scopus 로고
    • Nasal intermittent mandatory ventilation versus nasal continuous positive airway pressure for respiratory distress syndrome: A randomized, controlled, prospective study
    • Kugelman A, Feferkon I, Riskian R, Chistyakov I, Kaufman B, Bader D. Nasal intermittent mandatory ventilation versus nasal continuous positive airway pressure for respiratory distress syndrome: a randomized, controlled, prospective study. J Pediatr. 2007; 150(5):521-6.
    • (2007) J Pediatr , vol.150 , Issue.5 , pp. 521-526
    • Kugelman, A.1    Feferkon, I.2    Riskian, R.3    Chistyakov, I.4    Kaufman, B.5    Bader, D.6
  • 11
    • 0031963309 scopus 로고    scopus 로고
    • A comparison of underwater bubble continuous positive airway pressure with ventilator-derived continuous positive airway pressure in premature neonates ready for extubation
    • Lee KS, Dunn MS, Fenwick M, Shennan AT. A comparison of underwater bubble continuous positive airway pressure with ventilator-derived continuous positive airway pressure in premature neonates ready for extubation. Biol Neonate. 1998; 73(2):69-75.
    • (1998) Biol Neonate , vol.73 , Issue.2 , pp. 69-75
    • Lee, K.S.1    Dunn, M.S.2    Fenwick, M.3    Shennan, A.T.4
  • 12
    • 80052699421 scopus 로고    scopus 로고
    • Compare the effects of continuous positive airway pressure with two different methods to treat infants with respiratory distress syndrome
    • Persian
    • Mohamadizadeh M, Asadi AR, Sadeghnia AR. Compare the effects of continuous positive airway pressure with two different methods to treat infants with respiratory distress syndrome. J Isfahan Med Sch. 2011; 29(146):901-11 (Persian).
    • (2011) J Isfahan Med Sch , vol.29 , Issue.146 , pp. 901-911
    • Mohamadizadeh, M.1    Asadi, A.R.2    Sadeghnia, A.R.3
  • 13
    • 0034861056 scopus 로고    scopus 로고
    • A randomized control study comparing the infant flow driver with nasal continuous positive airway pressure in preterm infants
    • Mazella M, Bellini C, Calevo MG, Campone F, Massocco D, Mezzano P, et al. A randomized control study comparing the infant flow driver with nasal continuous positive airway pressure in preterm infants. Arch Dis Child Fetal Neonatal Ed. 2001; 85(2): F86-90.
    • (2001) Arch Dis Child Fetal Neonatal Ed , vol.85 , Issue.2 , pp. F86-F90
    • Mazella, M.1    Bellini, C.2    Calevo, M.G.3    Campone, F.4    Massocco, D.5    Mezzano, P.6
  • 14
    • 64149104989 scopus 로고    scopus 로고
    • A randomized controlled trial of post-extubation bubble continuous positive airway pressure versus infant flow driver continuous positive airway pressure in preterm infants with respiratory distress syndrome
    • Gupta S, Sinha SK, Tin W, Donn SM. A randomized controlled trial of post-extubation bubble continuous positive airway pressure versus infant flow driver continuous positive airway pressure in preterm infants with respiratory distress syndrome. J Pediatr. 2009; 154(5):645-50.
    • (2009) J Pediatr , vol.154 , Issue.5 , pp. 645-650
    • Gupta, S.1    Sinha, S.K.2    Tin, W.3    Donn, S.M.4
  • 15
    • 33748115659 scopus 로고    scopus 로고
    • An evaluation of bubble-CPAP in a neonatal unit in a developing country: Effective respiratory support that can be applied by nurses
    • Koyamaibole L, Kado J, Qovu JD, Colquhoun S, Duke T. An evaluation of bubble-CPAP in a neonatal unit in a developing country: effective respiratory support that can be applied by nurses. J Trop Pediatr. 2006; 52(4):249-53.
    • (2006) J Trop Pediatr , vol.52 , Issue.4 , pp. 249-253
    • Koyamaibole, L.1    Kado, J.2    Qovu, J.D.3    Colquhoun, S.4    Duke, T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.