메뉴 건너뛰기




Volumn 118, Issue 5, 2017, Pages 645-649

‘Failed supraglottic airway’: an algorithm for suboptimally placed supraglottic airway devices based on videolaryngoscopy

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHM; EDITORIAL; HUMAN; LARYNGOSCOPY; MEDICAL DEVICE COMPLICATION; PRIORITY JOURNAL; VIDEOENDOSCOPY; DEVICES; ENDOTRACHEAL INTUBATION; LARYNGEAL MASK; PROCEDURES; RESPIRATION CONTROL; STANDARDS;

EID: 85022223299     PISSN: 00070912     EISSN: 14716771     Source Type: Journal    
DOI: 10.1093/bja/aex093     Document Type: Editorial
Times cited : (46)

References (22)
  • 1
    • 0028261780 scopus 로고
    • Assessment of upper airway anatomy in awake, sedated and anaesthetised patients using magnetic resonance imaging
    • Shorten, GD, Opie, NJ, Graziotti, P, Morris, I, Khangure, M., Assessment of upper airway anatomy in awake, sedated and anaesthetised patients using magnetic resonance imaging. Anaesth Intensive Care 22 (1994), 165–169.
    • (1994) Anaesth Intensive Care , vol.22 , pp. 165-169
    • Shorten, G.D.1    Opie, N.J.2    Graziotti, P.3    Morris, I.4    Khangure, M.5
  • 3
    • 0028845817 scopus 로고
    • The triple airway manoeuvre for insertion of the laryngeal mask airway in paralyzed patients
    • Aoyama, K, Takenaka, I, Sata, T, Shigematsu, A., The triple airway manoeuvre for insertion of the laryngeal mask airway in paralyzed patients. Can J Anaesth 42 (1995), 1010–1016.
    • (1995) Can J Anaesth , vol.42 , pp. 1010-1016
    • Aoyama, K.1    Takenaka, I.2    Sata, T.3    Shigematsu, A.4
  • 4
    • 84907442021 scopus 로고    scopus 로고
    • Fiberoptic assessment of the laryngeal mask airway (Laryseal) position after one hour of positive pressure ventilation: an observational study
    • Moustafa, MA, Abdelhady, MM., Fiberoptic assessment of the laryngeal mask airway (Laryseal) position after one hour of positive pressure ventilation: an observational study. J Clin Anesth 26 (2014), 480–484.
    • (2014) J Clin Anesth , vol.26 , pp. 480-484
    • Moustafa, M.A.1    Abdelhady, M.M.2
  • 5
    • 0031794505 scopus 로고    scopus 로고
    • A prospective evaluation of clinical tests for placement of laryngeal mask airways
    • Joshi, S, Sciacca, RR, Solanki, DR, Young, WL, Mathru, MM., A prospective evaluation of clinical tests for placement of laryngeal mask airways. Anesthesiology 89 (1998), 1141–1146.
    • (1998) Anesthesiology , vol.89 , pp. 1141-1146
    • Joshi, S.1    Sciacca, R.R.2    Solanki, D.R.3    Young, W.L.4    Mathru, M.M.5
  • 6
    • 84981891675 scopus 로고
    • The use of the fibreoptic laryngoscope to confirm the position of the laryngeal mask
    • Payne, J., The use of the fibreoptic laryngoscope to confirm the position of the laryngeal mask. Anaesthesia, 44, 1989, 865.
    • (1989) Anaesthesia , vol.44 , pp. 865
    • Payne, J.1
  • 7
    • 85015987320 scopus 로고    scopus 로고
    • Vision-guided placement of supraglottic airway device (SAD) prevents airway obstruction – a prospective audit
    • Van Zundert, AAJ, Gatt, SP, Kumar, CM, van Zundert, TCRV., Vision-guided placement of supraglottic airway device (SAD) prevents airway obstruction – a prospective audit. Br J Anaesth 118 (2017), 462–463.
    • (2017) Br J Anaesth , vol.118 , pp. 462-463
    • Van Zundert, A.A.J.1    Gatt, S.P.2    Kumar, C.M.3    van Zundert, T.C.R.V.4
  • 9
    • 84869424358 scopus 로고    scopus 로고
    • Magnetic resonance imaging study of the in vivo position of the extraglottic airway devices i-gel™ and the LMA-Supreme™ in anaesthetized human volunteers
    • Russo, SG, Cremer, S, Eich, C, et al. Magnetic resonance imaging study of the in vivo position of the extraglottic airway devices i-gel™ and the LMA-Supreme™ in anaesthetized human volunteers. Br J Anaesth 109 (2012), 996–1004.
    • (2012) Br J Anaesth , vol.109 , pp. 996-1004
    • Russo, S.G.1    Cremer, S.2    Eich, C.3
  • 10
    • 79954538887 scopus 로고    scopus 로고
    • Fourth National Audit Project. Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: Anaesthesia
    • Cook, T, Woodall, N, Frerk, C., Fourth National Audit Project. Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: Anaesthesia. Br J Anaesth 106 (2011), 617–631.
    • (2011) Br J Anaesth , vol.106 , pp. 617-631
    • Cook, T.1    Woodall, N.2    Frerk, C.3
  • 11
    • 84951907435 scopus 로고    scopus 로고
    • Recommendations for standards of monitoring during anaesthesia and recovery 2015: Association of Anaesthetists of Great Britain and Ireland
    • Checketts, MR, Alladi, R, Ferguson, K, et al. Recommendations for standards of monitoring during anaesthesia and recovery 2015: Association of Anaesthetists of Great Britain and Ireland. Anaesthesia 71 (2016), 85–93.
    • (2016) Anaesthesia , vol.71 , pp. 85-93
    • Checketts, M.R.1    Alladi, R.2    Ferguson, K.3
  • 12
    • 84943245956 scopus 로고    scopus 로고
    • Time to abandon the ‘vintage’ laryngeal mask airway and adopt second-generation supraglottic airway devices as first choice
    • Cook, TM, Kelly, FE., Time to abandon the ‘vintage’ laryngeal mask airway and adopt second-generation supraglottic airway devices as first choice. Br J Anaesth 115 (2015), 497–499.
    • (2015) Br J Anaesth , vol.115 , pp. 497-499
    • Cook, T.M.1    Kelly, F.E.2
  • 13
    • 84943227157 scopus 로고    scopus 로고
    • Third generation supraglottic airway devices: an undefined concept and misused term. Time for an updated classification of supraglottic airway devices
    • Cook, TM., Third generation supraglottic airway devices: an undefined concept and misused term. Time for an updated classification of supraglottic airway devices. Br J Anaesth 115 (2015), 633–634.
    • (2015) Br J Anaesth , vol.115 , pp. 633-634
    • Cook, T.M.1
  • 14
    • 84978150776 scopus 로고    scopus 로고
    • st generation SAD – a reply
    • st generation SAD – a reply. Anaesthesia 71 (2016), 979–981.
    • (2016) Anaesthesia , vol.71 , pp. 979-981
    • Cook, T.M.1    Kelly, F.E.2
  • 15
    • 84977134267 scopus 로고    scopus 로고
    • further plea for a unified classification of supraglottic (extraglottic) airway devices
    • Cook, TMA., further plea for a unified classification of supraglottic (extraglottic) airway devices. Br J Anaesth 117 (2016), 136–137.
    • (2016) Br J Anaesth , vol.117 , pp. 136-137
    • Cook, T.M.A.1
  • 16
  • 17
    • 84871201466 scopus 로고    scopus 로고
    • Complications and failure of airway management
    • Cook, TM, MacDougall-Davis, SR., Complications and failure of airway management. Br J Anaesth 51 (2012), i68–i85.
    • (2012) Br J Anaesth , vol.51 , pp. i68-i85
    • Cook, T.M.1    MacDougall-Davis, S.R.2
  • 18
    • 84950129011 scopus 로고    scopus 로고
    • Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults
    • Frerk, C, Mitchell, VS, McNarry, AF, et al. Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults. Br J Anaesth 115 (2015), 828–848.
    • (2015) Br J Anaesth , vol.115 , pp. 828-848
    • Frerk, C.1    Mitchell, V.S.2    McNarry, A.F.3
  • 19
    • 84965111619 scopus 로고    scopus 로고
    • Malpositioning of supraglottic airway devices: preventive and corrective strategies
    • Van Zundert, AAJ, Kumar, CM, Van Zundert, TCRV., Malpositioning of supraglottic airway devices: preventive and corrective strategies. Br J Anaesth 116 (2016), 579–582.
    • (2016) Br J Anaesth , vol.116 , pp. 579-582
    • Van Zundert, A.A.J.1    Kumar, C.M.2    Van Zundert, T.C.R.V.3
  • 20
    • 85010338938 scopus 로고    scopus 로고
    • Seeing is believing: getting the best out of videolaryngoscopy
    • Kelly, FE, Cook, TM., Seeing is believing: getting the best out of videolaryngoscopy. Br J Anaesth 117:Suppl 1 (2016), i9–13.
    • (2016) Br J Anaesth , vol.117 , pp. i9-13
    • Kelly, F.E.1    Cook, T.M.2
  • 21
    • 84982890351 scopus 로고    scopus 로고
    • Comparison of a new visual stylet (Discopo)-guided laryngeal mask airway placement vs conventional blind technique: a prospective randomized study
    • Zhao, L, Zhang, J, Zhou, Q, Jiang, W., Comparison of a new visual stylet (Discopo)-guided laryngeal mask airway placement vs conventional blind technique: a prospective randomized study. J Clin Anesth 35 (2016), 85–89.
    • (2016) J Clin Anesth , vol.35 , pp. 85-89
    • Zhao, L.1    Zhang, J.2    Zhou, Q.3    Jiang, W.4
  • 22
    • 0020595084 scopus 로고
    • The laryngeal mask – a new concept in airway management
    • Brain, AIJ., The laryngeal mask – a new concept in airway management. Br J Anaesth 55 (1983), 801–805.
    • (1983) Br J Anaesth , vol.55 , pp. 801-805
    • Brain, A.I.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.