메뉴 건너뛰기




Volumn 40, Issue 7, 2017, Pages 328-334

Medium cut-off membranes - closer to the natural kidney removal function

Author keywords

[No Author keywords available]

Indexed keywords

REMOVAL FUNCTION;

EID: 85021891438     PISSN: 03913988     EISSN: 17246040     Source Type: Journal    
DOI: 10.5301/ijao.5000603     Document Type: Editorial
Times cited : (40)

References (55)
  • 1
    • 85120658556 scopus 로고    scopus 로고
    • th International Congress of the InternationSociety for Hemodialysis
    • th International Congress of the InternationSociety for Hemodialysis: Global Challenges in HemodialysiHemodial Int. 2015;19(Suppl 2):S3-S73.
    • (2015) Global Challenges in Hemodialysihemodial Int , vol.19 , pp. SS3-S73
    • Abstracts, F.P.1
  • 2
    • 85016212157 scopus 로고    scopus 로고
    • Performance of hemodalysis with novel medium cut-off dialyzers
    • Kirsch AH, Lyko R, Nilsson L-G, et al. Performance of hemodalysis with novel medium cut-off dialyzers. Nephrol Dial Tranplant. 2016;32(1):165-172.
    • (2016) Nephrol Dial Tranplant , vol.32 , Issue.1 , pp. 165-172
    • Kirsch, A.H.1    Lyko, R.2    Nilsson, L.-G.3
  • 3
    • 3242811296 scopus 로고    scopus 로고
    • Acute renal failure: Definitions, diagnosis, pathogenesis, and therapy
    • Schrier RW, Wang W, Poole B, Mitra A. Acute renal failure: definitions, diagnosis, pathogenesis, and therapy. J Clin Invest. 2004;114(1):5-14.
    • (2004) J Clin Invest , vol.114 , Issue.1 , pp. 5-14
    • Schrier, R.W.1    Wang, W.2    Poole, B.3    Mitra, A.4
  • 4
    • 82455162521 scopus 로고    scopus 로고
    • The contribution of chronic kidney disease to the global burden of major noncom-municable diseases
    • Couser WG, Remuzzi G, Mendis S, Tonelli M. The contribution of chronic kidney disease to the global burden of major noncom-municable diseases. Kidney Int. 2011;80(12):1258-1270.
    • (2011) Kidney Int , vol.80 , Issue.12 , pp. 1258-1270
    • Couser, W.G.1    Remuzzi, G.2    Mendis, S.3    Tonelli, M.4
  • 5
    • 0026449969 scopus 로고
    • The Evolution of a Synthetic Membrane for Renal Therapy
    • Polyamide
    • Polyamide - The Evolution of a Synthetic Membrane for Renal Therapy. Contrib Nephrol. 1992;96:1-144.
    • (1992) Contrib Nephrol , vol.96 , pp. 1-144
  • 6
    • 0021227521 scopus 로고
    • Biocompatibility of dialysis membranes: Effects of chronic complement activation
    • Hakim RM, Fearon DT, Lazarus JM, Perzanowski CS. Biocompatibility of dialysis membranes: effects of chronic complement activation. Kidney Int. 1984;26(2):194-200.
    • (1984) Kidney Int , vol.26 , Issue.2 , pp. 194-200
    • Hakim, R.M.1    Fearon, D.T.2    Lazarus, J.M.3    Perzanowski, C.S.4
  • 7
    • 0019178607 scopus 로고
    • Leukopenia, hypoxia, and complement function with different hemodialysis membranes
    • Jacob AI, Gavellas G, Zarco R, Perez G, Bourgoignie JJ. Leukopenia, hypoxia, and complement function with different hemodialysis membranes. Kidney Int. 1980;18(4):505-509.
    • (1980) Kidney Int , vol.18 , Issue.4 , pp. 505-509
    • Jacob, A.I.1    Gavellas, G.2    Zarco, R.3    Perez, G.4    Bourgoignie, J.J.5
  • 8
    • 85022068897 scopus 로고    scopus 로고
    • Lengerich, Germany: Pabst Science Publishers
    • Franz HE. Dialyse 2001. Lengerich, Germany: Pabst Science Publishers 2002.
    • (2002) Dialyse 2001
    • Franz, H.E.1
  • 10
    • 85021921043 scopus 로고    scopus 로고
    • Verfahrenstechnische Aspekte
    • Franz H E, Hörl W H, eds, Stuttgart-New York, Georg Thieme Verlag
    • Reinhardt B, Krick G. Verfahrenstechnische Aspekte. In: Franz H E, Hörl W H, eds. Blutreinigungsverfahren: Technik und Klinik. Stuttgart-New York, Georg Thieme Verlag 1997.
    • (1997) Blutreinigungsverfahren: Technik Und Klinik
    • Reinhardt, B.1    Krick, G.2
  • 11
    • 0035165623 scopus 로고    scopus 로고
    • Effect of vitamin E modified cellulose membrane on human lymphocyte, monocyte, and granulocyte CD11b/CD18 adhesion molecule expression during hemodialysis
    • Zaluska, WT, Ksiazek A, Roliski J. Effect of vitamin E modified cellulose membrane on human lymphocyte, monocyte, and granulocyte CD11b/CD18 adhesion molecule expression during hemodialysis. ASAIO J. 2001;47(6):619-22.
    • (2001) ASAIO J , vol.47 , Issue.6 , pp. 619-622
    • Zaluska, W.T.1    Ksiazek, A.2    Roliski, J.3
  • 12
    • 0022391603 scopus 로고
    • A new form of amyloid protein associated with chronic hemodialysis was identified as beta 2-microglobulin
    • Gejyo F, Yamada T, Odani S, et al. A new form of amyloid protein associated with chronic hemodialysis was identified as beta 2-microglobulin. Biochem Biophys Res Commun. 1985;129(3):701-706.
    • (1985) Biochem Biophys Res Commun , vol.129 , Issue.3 , pp. 701-706
    • Gejyo, F.1    Yamada, T.2    Odani, S.3
  • 13
    • 0021984908 scopus 로고
    • Complement activation during hemodialysis. Comparison of polysulfone and cuprophan membranes
    • Stannat S, Bahlmann J, Kiessling D, Koch KM, Deicher H, Peter HH. Complement activation during hemodialysis. Comparison of polysulfone and cuprophan membranes. Contrib Nephrol. 1985;46:102-108.
    • (1985) Contrib Nephrol , vol.46 , pp. 102-108
    • Stannat, S.1    Bahlmann, J.2    Kiessling, D.3    Koch, K.M.4    Deicher, H.5    Peter, H.H.6
  • 14
    • 0021947464 scopus 로고
    • The development of a polysulfone membrane. A new perspective in dialysis?
    • Streicher E, Schneider H. The development of a polysulfone membrane. A new perspective in dialysis? Contrib Nephrol. 1985;46:1-13.
    • (1985) Contrib Nephrol , vol.46 , pp. 1-13
    • Streicher, E.1    Schneider, H.2
  • 15
    • 0021905031 scopus 로고
    • Release of leukocyte elastase during hemodialysis. Effect of different dialysis membranes
    • Schaefer RM, Heidland A, Hörl WH. Release of leukocyte elastase during hemodialysis. Effect of different dialysis membranes. Contrib Nephrol. 1985;46:109-117.
    • (1985) Contrib Nephrol , vol.46 , pp. 109-117
    • Schaefer, R.M.1    Heidland, A.2    Hörl, W.H.3
  • 16
    • 62149106664 scopus 로고    scopus 로고
    • Membrane Permeability Outcome (MPO) Study Group. Effect of membrane permeability on survival of hemodialysis patients
    • Locatelli F, Martin-Malo A, Hannedouche T, et al. Membrane Permeability Outcome (MPO) Study Group. Effect of membrane permeability on survival of hemodialysis patients. J Am Soc Nephrol. 2009;20(3):645-654.
    • (2009) J am Soc Nephrol , vol.20 , Issue.3 , pp. 645-654
    • Locatelli, F.1    Martin-Malo, A.2    Hannedouche, T.3
  • 17
    • 84880954015 scopus 로고    scopus 로고
    • Extended Characterization of a New Class of Dialysis Membranes: The High Cut-Off Membranes
    • Boschetti-de-Fierro A, Voigt M, Storr M, Krause B. Extended Characterization of a New Class of Dialysis Membranes: the High Cut-Off Membranes. Int J Artif Organs. 2013;36(7): 455-463.
    • (2013) Int J Artif Organs , vol.36 , Issue.7 , pp. 455-463
    • Boschetti-De-Fierro, A.1    Voigt, M.2    Storr, M.3    Krause, B.4
  • 18
    • 77955881855 scopus 로고    scopus 로고
    • ‘Super High-Flux’ or ‘High Cut-Off’ Hemofiltration and Hemodialysis
    • Suzuki H, Hirasa-wa H, eds
    • Naka T, Haase M, Bellomo R. ‘Super High-Flux’ or ‘High Cut-Off’ Hemofiltration and Hemodialysis. In: Suzuki H, Hirasa-wa H, eds. Acute Blood Purification. Basel: S. Karger. 2010; 181-189.
    • (2010) Acute Blood Purification. Basel: S. Karger , pp. 181-189
    • Naka, T.1    Haase, M.2    Bellomo, R.3
  • 19
    • 58149177638 scopus 로고    scopus 로고
    • Serum free-light chain removal by high cutoff hemodialysis: Optimizing removal and supportive care
    • Hutchison CA, Harding S, Mead G, et al. Serum free-light chain removal by high cutoff hemodialysis: optimizing removal and supportive care. Artif Organs. 2008;32(12):910-917.
    • (2008) Artif Organs , vol.32 , Issue.12 , pp. 910-917
    • Hutchison, C.A.1    Harding, S.2    Mead, G.3
  • 20
    • 84867189628 scopus 로고    scopus 로고
    • Randomized controlled pilot study of 2 weeks treatment with high cutoff membrane for hemodialysis patients with elevated C-reactive protein
    • Fiedler R, Neugebauer F, Ulrich C, et al. Randomized controlled pilot study of 2 weeks treatment with high cutoff membrane for hemodialysis patients with elevated C-reactive protein. Artif Organs. 2012;36(10):886-893.
    • (2012) Artif Organs , vol.36 , Issue.10 , pp. 886-893
    • Fiedler, R.1    Neugebauer, F.2    Ulrich, C.3
  • 21
    • 84884912561 scopus 로고    scopus 로고
    • Endotoxemia after high cutoff hemodialysis for treatment of patient with multiple myeloma can be prevented by using ultrapure dialysate: A case report
    • Gong D, Ji D, Zhang K, et al. Endotoxemia after high cutoff hemodialysis for treatment of patient with multiple myeloma can be prevented by using ultrapure dialysate: a case report. Hemodial Int. 2013;17(4):618-623.
    • (2013) Hemodial Int , vol.17 , Issue.4 , pp. 618-623
    • Gong, D.1    Ji, D.2    Zhang, K.3
  • 22
    • 85021901599 scopus 로고    scopus 로고
    • N50 212 rev
    • Operator manual for the Baxter-Gambro HCO 1100 Instructions for use, N50 212 rev. 003-1.
  • 23
    • 33845881703 scopus 로고    scopus 로고
    • Confirmation of high cytokine clearance by hemofiltration with a cellulose tri-acetate membrane with large pores: An in vivo study
    • Delanaye P, Lambermont B, Dogné JM, et al. Confirmation of high cytokine clearance by hemofiltration with a cellulose tri-acetate membrane with large pores: an in vivo study. Int J Artif Organs. 2006;29(10):944-948.
    • (2006) Int J Artif Organs , vol.29 , Issue.10 , pp. 944-948
    • Delanaye, P.1    Lambermont, B.2    Dogné, J.M.3
  • 24
    • 48349100276 scopus 로고    scopus 로고
    • Effect of high fiber density ratio polysulfone dialyzer on protein removal
    • Tomo T, Matsuyama M, Nakata T, et al. Effect of high fiber density ratio polysulfone dialyzer on protein removal. Blood Purif. 2008;26(4):347-353.
    • (2008) Blood Purif , vol.26 , Issue.4 , pp. 347-353
    • Tomo, T.1    Matsuyama, M.2    Nakata, T.3
  • 25
    • 12344332476 scopus 로고    scopus 로고
    • Glycoxidation and inflammatory markers in patients on treatment with PMMA-based protein-leaking dialyzers
    • Galli F, Benedetti S, Floridi A, et al. Glycoxidation and inflammatory markers in patients on treatment with PMMA-based protein-leaking dialyzers. Kidney Int. 2005;67(2):750-759.
    • (2005) Kidney Int , vol.67 , Issue.2 , pp. 750-759
    • Galli, F.1    Benedetti, S.2    Floridi, A.3
  • 26
    • 33947306104 scopus 로고    scopus 로고
    • The impact of standard high-flux polysulfone versus novel high-flux polysulfone dialysis membranes on inflammatory markers: A randomized, single-blinded, controlled clinical trial
    • Kerr PG, Sutherland WH, de Jong S, Vaithalingham I, Williams SM, Walker RJ. The impact of standard high-flux polysulfone versus novel high-flux polysulfone dialysis membranes on inflammatory markers: a randomized, single-blinded, controlled clinical trial. Am J Kidney Dis. 2007;49(4): 533-539.
    • (2007) Am J Kidney Dis , vol.49 , Issue.4 , pp. 533-539
    • Kerr, P.G.1    Sutherland, W.H.2    De Jong, S.3    Vaithalingham, I.4    Williams, S.M.5    Walker, R.J.6
  • 27
    • 28444451861 scopus 로고    scopus 로고
    • Protein-leaking membranes for hemodialysis: A new class of membranes in search of an application?
    • Ward RA. Protein-leaking membranes for hemodialysis: a new class of membranes in search of an application? J Am Soc Nephrol. 2005;16(8):2421-2430.
    • (2005) J am Soc Nephrol , vol.16 , Issue.8 , pp. 2421-2430
    • Ward, R.A.1
  • 29
    • 77954376004 scopus 로고    scopus 로고
    • Prospective evaluation of the change of predialysis protein-bound uremic solute concentration with postdilution online hemodiafiltration
    • Meert N, Waterloos MA, Van Landschoot M, et al. Prospective evaluation of the change of predialysis protein-bound uremic solute concentration with postdilution online hemodiafiltration. Artif Organs. 2010;34(7):580-585.
    • (2010) Artif Organs , vol.34 , Issue.7 , pp. 580-585
    • Meert, N.1    Waterloos, M.A.2    Van Landschoot, M.3
  • 30
    • 84863528247 scopus 로고    scopus 로고
    • European Uremic Toxin Work Group. Normal and pathologic concentrations of uremic toxins
    • Duranton F, Cohen G, De Smet R, et al. European Uremic Toxin Work Group. Normal and pathologic concentrations of uremic toxins. J Am Soc Nephrol. 2012;23(7):1258-1270.
    • (2012) J am Soc Nephrol , vol.23 , Issue.7 , pp. 1258-1270
    • Duranton, F.1    Cohen, G.2    De Smet, R.3
  • 31
    • 0024358898 scopus 로고
    • High-flux synthetic versus cellulosic membranes for β 2-microglobulin removal during hemodialysis, hemodiafiltration and hemofiltration
    • Floege J, Granolleras C, Deschodt G, et al. High-flux synthetic versus cellulosic membranes for β 2-microglobulin removal during hemodialysis, hemodiafiltration and hemofiltration. Nephrol Dial Transplant. 1989;4(7):653-657.
    • (1989) Nephrol Dial Transplant , vol.4 , Issue.7 , pp. 653-657
    • Floege, J.1    Granolleras, C.2    Deschodt, G.3
  • 32
    • 84899076804 scopus 로고    scopus 로고
    • Extracorporeal removal of uremic toxins: Can we still do better?
    • Eloot S, Ledebo I, Ward RA. Extracorporeal removal of uremic toxins: can we still do better? Semin Nephrol. 2014;34(2): 209-227.
    • (2014) Semin Nephrol , vol.34 , Issue.2 , pp. 209-227
    • Eloot, S.1    Ledebo, I.2    Ward, R.A.3
  • 33
    • 84922841679 scopus 로고    scopus 로고
    • Uremic toxins and their effects on multiple organ systems
    • Lisowska-Myjak B. Uremic toxins and their effects on multiple organ systems. Nephron Clin Pract. 2014;128(3-4):303-311.
    • (2014) Nephron Clin Pract , vol.128 , Issue.3-4 , pp. 303-311
    • Lisowska-Myjak, B.1
  • 34
    • 84874615642 scopus 로고    scopus 로고
    • EUDIAL group. Online haemodiafiltration: Definition, dose quantification and safety revisited
    • Tattersall JE, Ward RA. EUDIAL group. Online haemodiafiltration: definition, dose quantification and safety revisited. Nephrol Dial Transplant. 2013;28(3):542-550.
    • (2013) Nephrol Dial Transplant , vol.28 , Issue.3 , pp. 542-550
    • Tattersall, J.E.1    Ward, R.A.2
  • 35
    • 77949542077 scopus 로고    scopus 로고
    • Haemodiafiltration-optimal efficiency and safety
    • Ledebo I, Blankestijn PJ. Haemodiafiltration-optimal efficiency and safety. NDT Plus. 2010;3(1):8-16.
    • (2010) NDT Plus , vol.3 , Issue.1 , pp. 8-16
    • Ledebo, I.1    Blankestijn, P.J.2
  • 36
    • 84941895319 scopus 로고    scopus 로고
    • Optimization of the convection volume in online post-dilution haemodiafiltration: Practical and technical issues
    • Chapdelaine I, de Roij van Zuijdweifn CLM, Mostovaya IM, et al. Optimization of the convection volume in online post-dilution haemodiafiltration: practical and technical issues. Clin Kidney J. 2015;8(2):191-198.
    • (2015) Clin Kidney J , vol.8 , Issue.2 , pp. 191-198
    • Chapdelaine, I.1    De Roij Van Zuijdweifn, C.L.M.2    Mostovaya, I.M.3
  • 37
    • 58449118342 scopus 로고    scopus 로고
    • Effective removal of protein-bound uraemic solutes by different convective strategies: A prospective trial
    • Meert N, Eloot S, Waterloos MA, et al. Effective removal of protein-bound uraemic solutes by different convective strategies: a prospective trial. Nephrol Dial Transplant. 2009;24(2): 562-570.
    • (2009) Nephrol Dial Transplant , vol.24 , Issue.2 , pp. 562-570
    • Meert, N.1    Eloot, S.2    Waterloos, M.A.3
  • 38
    • 84881026236 scopus 로고    scopus 로고
    • Mixed matrix hollow fiber membranes for removal of protein-bound toxins from human plasma
    • Tijink MS, Wester M, Glorieux G, et al. Mixed matrix hollow fiber membranes for removal of protein-bound toxins from human plasma. Biomaterials. 2013;34(32):7819-7828.
    • (2013) Biomaterials , vol.34 , Issue.32 , pp. 7819-7828
    • Tijink, M.S.1    Wester, M.2    Glorieux, G.3
  • 39
    • 40149112160 scopus 로고    scopus 로고
    • Removal of the uremic retention solute p-cresol using fractionated plasma separation and adsorption
    • Meijers BK, Weber V, Bammens B, et al. Removal of the uremic retention solute p-cresol using fractionated plasma separation and adsorption. Artif Organs. 2008;32(3):214-219.
    • (2008) Artif Organs , vol.32 , Issue.3 , pp. 214-219
    • Meijers, B.K.1    Weber, V.2    Bammens, B.3
  • 40
    • 84875928447 scopus 로고    scopus 로고
    • Removal of protein-bound, hydrophobic uremic toxins by a combined fractionated plasma separation and adsorption technique
    • Brettschneider F, Tölle M, von der Giet M, et al. Removal of protein-bound, hydrophobic uremic toxins by a combined fractionated plasma separation and adsorption technique. Artif Organs. 2013;37(4):409-416.
    • (2013) Artif Organs , vol.37 , Issue.4 , pp. 409-416
    • Brettschneider, F.1    Tölle, M.2    Von Der Giet, M.3
  • 41
    • 0031725029 scopus 로고    scopus 로고
    • Biological basis of hypoalbuminemia in ESRD
    • Kaysen GA. Biological basis of hypoalbuminemia in ESRD. J Am Soc Nephrol. 1998;9(12):2368-2376.
    • (1998) J am Soc Nephrol , vol.9 , Issue.12 , pp. 2368-2376
    • Kaysen, G.A.1
  • 42
    • 0037385323 scopus 로고    scopus 로고
    • High permeability of dialysis membranes: What is the limit of albumin loss?
    • Krieter DH, Canaud B. High permeability of dialysis membranes: what is the limit of albumin loss? Nephrol Dial Transplant. 2003;18(4):651-654.
    • (2003) Nephrol Dial Transplant , vol.18 , Issue.4 , pp. 651-654
    • Krieter, D.H.1    Canaud, B.2
  • 43
    • 0035116987 scopus 로고    scopus 로고
    • Serum albumin and other serum protein fractions in stable patients on peritoneal dialysis
    • Caravaca F, Arrobas M, Dominguez C. Serum albumin and other serum protein fractions in stable patients on peritoneal dialysis. Perit Dial Int. 2000;20(6): 703-707.
    • (2000) Perit Dial Int , vol.20 , Issue.6 , pp. 703-707
    • Caravaca, F.1    Arrobas, M.2    Dominguez, C.3
  • 44
    • 85015605982 scopus 로고    scopus 로고
    • Are all dialyzers compatible with the convective volumes suggested for postdilution online hemodiafiltration?
    • Potier J, Queffeulou G, Bouet J. Are all dialyzers compatible with the convective volumes suggested for postdilution online hemodiafiltration? Int J Artif Organs. 2016;39(9):460-470.
    • (2016) Int J Artif Organs , vol.39 , Issue.9 , pp. 460-470
    • Potier, J.1    Queffeulou, G.2    Bouet, J.3
  • 46
    • 0028899012 scopus 로고
    • Dialysate protein losses with bleach processed polysulphone dialyzers
    • Kaplan AA, Halley SE, Lapkin RA, Graeber CW. Dialysate protein losses with bleach processed polysulphone dialyzers. Kidney Int. 1995;47(2):573-578.
    • (1995) Kidney Int , vol.47 , Issue.2 , pp. 573-578
    • Kaplan, A.A.1    Halley, S.E.2    Lapkin, R.A.3    Graeber, C.W.4
  • 47
    • 85021954197 scopus 로고    scopus 로고
    • Beta2-microglobulin removal and albumin losses in post-dilution hemodiafiltration: Membrane effect [abstract]
    • Le Roy FHM, Claeyssens S, Bertrand D, Freguia C, Godin M. Beta2-microglobulin removal and albumin losses in post-dilution hemodiafiltration: membrane effect [abstract]. Clin Kidney J. 2009;2(Suppl 2):ii1150.
    • (2009) Clin Kidney J , vol.2
    • Le Roy, F.H.M.1    Claeyssens, S.2    Bertrand, D.3    Freguia, C.4    Godin, M.5
  • 48
    • 84928104097 scopus 로고    scopus 로고
    • Factors associated with albumin loss in post-dilution hemodiafiltration and nutritional consequences
    • Fournier A, Birmelé B, François M, Prat L, Halimi JM. Factors associated with albumin loss in post-dilution hemodiafiltration and nutritional consequences. Int J Artif Organs. 2015;38(2): 76-82.
    • (2015) Int J Artif Organs , vol.38 , Issue.2 , pp. 76-82
    • Fournier, A.1    Birmelé, B.2    François, M.3    Prat, L.4    Halimi, J.M.5
  • 49
    • 84896436903 scopus 로고    scopus 로고
    • Elimination of large uremic toxins by a dialyzer specifically designed for high-volume convective therapies
    • Maduell F, Arias-Guillen M, Fontseré N, et al. Elimination of large uremic toxins by a dialyzer specifically designed for high-volume convective therapies. Blood Purif. 2014;37(2):125-130.
    • (2014) Blood Purif , vol.37 , Issue.2 , pp. 125-130
    • Maduell, F.1    Arias-Guillen, M.2    Fontseré, N.3
  • 50
    • 80052066173 scopus 로고    scopus 로고
    • Albumin loss under the use of the high-performance membrane
    • Tsuchida K, Minakuchi J. Albumin loss under the use of the high-performance membrane. Contrib Nephrol. 2011;173:76-83.
    • (2011) Contrib Nephrol , vol.173 , pp. 76-83
    • Tsuchida, K.1    Minakuchi, J.2
  • 51
    • 0036056250 scopus 로고    scopus 로고
    • Cardiac effects of chronic inflammation in dialysis patients
    • Santoro A, Mancini E. Cardiac effects of chronic inflammation in dialysis patients. Nephrol Dial Transplant. 2002;17(Suppl 8): 10-15.
    • (2002) Nephrol Dial Transplant , vol.17 , pp. 10-15
    • Santoro, A.1    Mancini, E.2
  • 52
    • 53749090099 scopus 로고    scopus 로고
    • Aspects of immune dysfunction in end-stage renal disease
    • Kato S, Chmielewski M, Honda H, et al. Aspects of immune dysfunction in end-stage renal disease. Clin J Am Soc Nephrol. 2008;3(5):1526-1533.
    • (2008) Clin J am Soc Nephrol , vol.3 , Issue.5 , pp. 1526-1533
    • Kato, S.1    Chmielewski, M.2    Honda, H.3
  • 53
    • 0033825087 scopus 로고    scopus 로고
    • Effect of high-flux dialysis on the anaemia of haemodialysis patients
    • Locatelli F, Andrulli S, Pecchini F, et al. Effect of high-flux dialysis on the anaemia of haemodialysis patients. Nephrol Dial Transplant. 2000;15(9):1399-1409.
    • (2000) Nephrol Dial Transplant , vol.15 , Issue.9 , pp. 1399-1409
    • Locatelli, F.1    Andrulli, S.2    Pecchini, F.3
  • 55
    • 85022031689 scopus 로고    scopus 로고
    • Large middle-molecule removal during hemodialysis using a novel medium cutoff dialyzer
    • Kirsch AH, Lechner P, Nilsson L-G, et al. Large middle-molecule removal during hemodialysis using a novel medium cutoff dialyzer. Nephrol Dial Transplant. 2016;31(Suppl 1):i230.
    • (2016) Nephrol Dial Transplant , vol.31 , pp. 230
    • Kirsch, A.H.1    Lechner, P.2    Nilsson, L.-G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.