메뉴 건너뛰기




Volumn 51, Issue 3, 2017, Pages 591-596

Novel minimally invasive surgical approach using an external ventricular assist device and extracorporeal membrane oxygenation in refractory cardiogenic shock

Author keywords

Cardiogenic shock; Extracorporeal membrane oxygenation; Ventricular assist device

Indexed keywords

ACUTE HEART INFARCTION; ADULT; ARTERY CATHETERIZATION; ARTICLE; BLEEDING; CANNULATION; CARDIOGENIC SHOCK; CARDIOPULMONARY BYPASS; CENTRIFUGAL PUMP; CEREBROVASCULAR DISEASE; CLINICAL ARTICLE; EXTRACORPOREAL OXYGENATION; FEMALE; FEMORAL VEIN; FEMORAL VENOUS CANNULATION; HEART MUSCLE REFRACTORY PERIOD; HEART TRANSPLANTATION; HEART VENTRICLE FAILURE; HOSPITAL MORTALITY; HUMAN; LUNG COMPLICATION; MALE; MECHANICAL CIRCULATORY SUPPORT; MIDDLE AGED; MINIMALLY INVASIVE CARDIAC SURGERY; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SHORT COURSE THERAPY; THORACOTOMY; VENTRICULAR ASSIST DEVICE; VENTRICULAR CANNULA (HEART); AGED; COMPLICATION; FEASIBILITY STUDY; HEART ASSIST DEVICE; HEART FAILURE; HEART INFARCTION; HEMODYNAMICS; KAPLAN MEIER METHOD; MINIMALLY INVASIVE SURGERY; PATHOPHYSIOLOGY; PHYSIOLOGY; POSTOPERATIVE CARE; PROCEDURES; PROSTHESIS IMPLANTATION; SHOCK, CARDIOGENIC; TREATMENT OUTCOME;

EID: 85020018016     PISSN: 10107940     EISSN: 1873734X     Source Type: Journal    
DOI: 10.1093/ejcts/ezw349     Document Type: Article
Times cited : (37)

References (13)
  • 1
    • 84908128475 scopus 로고    scopus 로고
    • National trends in the utilization of short-term mechanical circulatory support: incidence, outcomes, and cost analysis
    • Stretch R, Sauer CM, Yuh DD, Bonde P. National trends in the utilization of short-term mechanical circulatory support: incidence, outcomes, and cost analysis. J Am Coll Cardiol 2014;64:1407-15
    • (2014) J Am Coll Cardiol , vol.64 , pp. 1407-1415
    • Stretch, R.1    Sauer, C.M.2    Yuh, D.D.3    Bonde, P.4
  • 2
    • 84892740281 scopus 로고    scopus 로고
    • Mechanical circulatory support in cardiogenic shock
    • Werdan K, Gielen S, Ebelt H, Hochman JS. Mechanical circulatory support in cardiogenic shock. Eur Heart J 2014;35:156-67
    • (2014) Eur Heart J , vol.35 , pp. 156-167
    • Werdan, K.1    Gielen, S.2    Ebelt, H.3    Hochman, J.S.4
  • 3
    • 84919666770 scopus 로고    scopus 로고
    • Bridge-to-decision therapy with a continuous-flow external ventricular assist device in refractory cardiogenic shock of various causes
    • Takayama H, Soni L, Kalesan B, Truby LK, Ota T, Cedola S et al. Bridge-to-decision therapy with a continuous-flow external ventricular assist device in refractory cardiogenic shock of various causes. Circ Heart Fail 2014;7:799-806
    • (2014) Circ Heart Fail , vol.7 , pp. 799-806
    • Takayama, H.1    Soni, L.2    Kalesan, B.3    Truby, L.K.4    Ota, T.5    Cedola, S.6
  • 4
    • 77956879395 scopus 로고    scopus 로고
    • Less invasive left ventricular assist device placement for difficult resternotomy
    • Takayama H, Naka Y, Jorde UP, Stewart AS. Less invasive left ventricular assist device placement for difficult resternotomy. J Thorac Cardiovasc Surg 2010;140:932-3
    • (2010) J Thorac Cardiovasc Surg , vol.140 , pp. 932-933
    • Takayama, H.1    Naka, Y.2    Jorde, U.P.3    Stewart, A.S.4
  • 5
    • 84872283890 scopus 로고    scopus 로고
    • Predicting survival in patients receiving continuous flow left ventricular assist devices: the HeartMate II risk score
    • Cowger J, Sundareswaran K, Rogers JG, Park SJ, Pagani FD, Bhat G et al. Predicting survival in patients receiving continuous flow left ventricular assist devices: the HeartMate II risk score. J Am Coll Cardiol 2013;61:313-21
    • (2013) J Am Coll Cardiol , vol.61 , pp. 313-321
    • Cowger, J.1    Sundareswaran, K.2    Rogers, J.G.3    Park, S.J.4    Pagani, F.D.5    Bhat, G.6
  • 7
    • 84905034947 scopus 로고    scopus 로고
    • A minimally invasive off-pump implantation technique for continuous-flow left ventricular assist devices: early experience
    • Strueber M, Meyer AL, Feussner M, Ender J, Correia JC, Mohr FW. A minimally invasive off-pump implantation technique for continuous-flow left ventricular assist devices: early experience. J Heart Lung Transplant 2014;33:851-6
    • (2014) J Heart Lung Transplant , vol.33 , pp. 851-856
    • Strueber, M.1    Meyer, A.L.2    Feussner, M.3    Ender, J.4    Correia, J.C.5    Mohr, F.W.6
  • 8
    • 84920041812 scopus 로고    scopus 로고
    • In-hospital outcomes of a minimally invasive off-pump left thoracotomy approach using a centrifugal continuous-flow left ventricular assist device
    • Sileshi B, Haglund NA, Davis ME, Tricarico NM, Stulak JM, Khalpey Z et al. In-hospital outcomes of a minimally invasive off-pump left thoracotomy approach using a centrifugal continuous-flow left ventricular assist device. J Heart Lung Transplant 2015;34:107-112
    • (2015) J Heart Lung Transplant , vol.34 , pp. 107-112
    • Sileshi, B.1    Haglund, N.A.2    Davis, M.E.3    Tricarico, N.M.4    Stulak, J.M.5    Khalpey, Z.6
  • 10
    • 84926420377 scopus 로고    scopus 로고
    • The heartmate risk score predicts morbidity and mortality in unselected left ventricular assist device recipients and risk stratifies INTERMACS class 1 patients
    • Adamo L, Nassif M, Tibrewala A, Novak E, Vader J, Silvestry SC et al. The heartmate risk score predicts morbidity and mortality in unselected left ventricular assist device recipients and risk stratifies INTERMACS class 1 patients. JACC Heart Fail 2015;3:283-90
    • (2015) JACC Heart Fail , vol.3 , pp. 283-290
    • Adamo, L.1    Nassif, M.2    Tibrewala, A.3    Novak, E.4    Vader, J.5    Silvestry, S.C.6
  • 11
    • 84958660435 scopus 로고    scopus 로고
    • Right ventricular assist device with membrane oxygenator support for right ventricular failure following implantable left ventricular assist device placement
    • Leidenfrost J, Prasad S, Itoh A, Lawrance CP, Bell JM, Silvestry SC. Right ventricular assist device with membrane oxygenator support for right ventricular failure following implantable left ventricular assist device placement. Eur J Cardiothorac Surg 2016;49:73-7
    • (2016) Eur J Cardiothorac Surg , vol.49 , pp. 73-77
    • Leidenfrost, J.1    Prasad, S.2    Itoh, A.3    Lawrance, C.P.4    Bell, J.M.5    Silvestry, S.C.6
  • 12
    • 84893370127 scopus 로고    scopus 로고
    • Outcome of unplanned right ventricular assist device support for severe right heart failure after implantable left ventricular assist device insertion
    • Takeda K, Nakay, Yang JA, Uriel N, Colombo PC, Jorde UP et al. Outcome of unplanned right ventricular assist device support for severe right heart failure after implantable left ventricular assist device insertion. J Heart Lung Transplant 2014;33:141-8
    • (2014) J Heart Lung Transplant , vol.33 , pp. 141-148
    • Takeda, K.1    Nakay, R.2    Yang, J.A.3    Uriel, N.4    Colombo, P.C.5    Jorde, U.P.6
  • 13
    • 63149091807 scopus 로고    scopus 로고
    • Changes in right ventricular function during continuous-flow left ventricular assist device support
    • Maeder MT, Leet A, Ross A, Esmore D, Kaye DM. Changes in right ventricular function during continuous-flow left ventricular assist device support. J Heart Lung Transplant 2009;28:360-6
    • (2009) J Heart Lung Transplant , vol.28 , pp. 360-366
    • Maeder, M.T.1    Leet, A.2    Ross, A.3    Esmore, D.4    Kaye, D.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.