메뉴 건너뛰기




Volumn 45, Issue 8, 2017, Pages 1317-1324

Nonlinear imputation of pa o 2/F io 2 from Sp o 2/F io 2 among mechanically ventilated patients in the ICU: A prospective, observational study

(16)  Brown, Samuel M a   Duggal, Abhijit b   Hou, Peter C c   Tidswell, Mark d   Khan, Akram e   Exline, Matthew f   Park, Pauline K g   Schoenfeld, David A h   Liu, Ming h   Grissom, Colin K a   Moss, Marc i   Rice, Todd W j   Hough, Catherine L k   Rivers, Emanuel l   Thompson, B Taylor h   Brower, Roy G a  


Author keywords

acute respiratory distress syndrome; pulse oximetry; respiratory failure; severity scores

Indexed keywords

DOPAMINE; EPINEPHRINE; NORADRENALIN; PHENYLEPHRINE; VASOPRESSIN;

EID: 85019646970     PISSN: 00903493     EISSN: 15300293     Source Type: Journal    
DOI: 10.1097/CCM.0000000000002514     Document Type: Article
Times cited : (85)

References (25)
  • 1
    • 84862490519 scopus 로고    scopus 로고
    • Acute respiratory distress syndrome: The Berlin Definition
    • ARDS Definition Task Force
    • Ranieri VM, Rubenfeld GD, Thompson BT, et al; ARDS Definition Task Force: Acute respiratory distress syndrome: The Berlin Definition. JAMA 2012; 307:2526-2533
    • (2012) JAMA , vol.307 , pp. 2526-2533
    • Ranieri, V.M.1    Rubenfeld, G.D.2    Thompson, B.T.3
  • 2
    • 0030015661 scopus 로고    scopus 로고
    • The SOFA (Sepsis-related Organ Failure Assessment) score to describe organ dysfunction/failure. on behalf of the Working Group on Sepsis-Related Problems of the European Society of Intensive Care Medicine
    • Vincent JL, Moreno R, Takala J, et al: The SOFA (Sepsis-related Organ Failure Assessment) score to describe organ dysfunction/failure. On behalf of the Working Group on Sepsis-Related Problems of the European Society of Intensive Care Medicine. Intensive Care Med 1996; 22:707-710
    • (1996) Intensive Care Med , vol.22 , pp. 707-710
    • Vincent, J.L.1    Moreno, R.2    Takala, J.3
  • 3
    • 77956624975 scopus 로고    scopus 로고
    • Indwelling arterial catheters in the intensive care unit: Necessary and beneficial, or a harmful crutch?
    • Garland A, Connors AF Jr: Indwelling arterial catheters in the intensive care unit: Necessary and beneficial, or a harmful crutch?. Am J Respir Crit Care Med 2010; 182:133-134
    • (2010) Am J Respir Crit Care Med , vol.182 , pp. 133-134
    • Garland, A.1    Connors, A.F.2
  • 4
    • 84910010996 scopus 로고    scopus 로고
    • Arterial lines in the ICU: A call for rigorous controlled trials
    • Garland A: Arterial lines in the ICU: A call for rigorous controlled trials. Chest 2014; 146:1155-1158
    • (2014) Chest , vol.146 , pp. 1155-1158
    • Garland, A.1
  • 5
    • 84896393465 scopus 로고    scopus 로고
    • The role of venous blood gas in the emergency department: A systematic review and metaanalysis
    • Bloom BM, Grundlingh J, Bestwick JP, et al: The role of venous blood gas in the emergency department: A systematic review and metaanalysis. Eur J Emerg Med 2014; 21:81-88
    • (2014) Eur J Emerg Med , vol.21 , pp. 81-88
    • Bloom, B.M.1    Grundlingh, J.2    Bestwick, J.P.3
  • 6
    • 34548037928 scopus 로고    scopus 로고
    • Comparison of the Spo2/Fio2 ratio and the Pao2/Fio2 ratio in patients with acute lung injury or ARDS
    • National Institutes of Health, National Heart, Lung, and Blood Institute ARDS Network
    • Rice TW, Wheeler AP, Bernard GR, et al; National Institutes of Health, National Heart, Lung, and Blood Institute ARDS Network: Comparison of the Spo2/Fio2 ratio and the Pao2/Fio2 ratio in patients with acute lung injury or ARDS. Chest 2007; 132:410-417
    • (2007) Chest , vol.132 , pp. 410-417
    • Rice, T.W.1    Wheeler, A.P.2    Bernard, G.R.3
  • 7
    • 67650495397 scopus 로고    scopus 로고
    • Derivation and validation of Spo2/Fio2 ratio to impute for Pao2/Fio2 ratio in the respiratory component of the Sequential Organ Failure Assessment score
    • Pandharipande PP, Shintani AK, Hagerman HE, et al: Derivation and validation of Spo2/Fio2 ratio to impute for Pao2/Fio2 ratio in the respiratory component of the Sequential Organ Failure Assessment score. Crit Care Med 2009; 37:1317-1321
    • (2009) Crit Care Med , vol.37 , pp. 1317-1321
    • Pandharipande, P.P.1    Shintani, A.K.2    Hagerman, H.E.3
  • 8
    • 62149152690 scopus 로고    scopus 로고
    • Comparison of the pulse oximetric saturation/fraction of inspired oxygen ratio and the Pao2/fraction of inspired oxygen ratio in children
    • Khemani RG, Patel NR, Bart RD 3rd, et al: Comparison of the pulse oximetric saturation/fraction of inspired oxygen ratio and the Pao2/fraction of inspired oxygen ratio in children. Chest 2009; 135:662-668
    • (2009) Chest , vol.135 , pp. 662-668
    • Khemani, R.G.1    Patel, N.R.2    Bart, R.D.3
  • 9
    • 84858786064 scopus 로고    scopus 로고
    • Comparison of Spo2 to Pao2 based markers of lung disease severity for children with acute lung injury
    • Pediatric Acute Lung Injury and Sepsis Network Investigators (PALISI)
    • Khemani RG, Thomas NJ, Venkatachalam V, et al; Pediatric Acute Lung Injury and Sepsis Network Investigators (PALISI): Comparison of Spo2 to Pao2 based markers of lung disease severity for children with acute lung injury. Crit Care Med 2012; 40:1309-1316
    • (2012) Crit Care Med , vol.40 , pp. 1309-1316
    • Khemani, R.G.1    Thomas, N.J.2    Venkatachalam, V.3
  • 10
    • 75149139505 scopus 로고    scopus 로고
    • Defining acute lung disease in children with the oxygenation saturation index
    • Thomas NJ, Shaffer ML, Willson DF, et al: Defining acute lung disease in children with the oxygenation saturation index. Pediatr Crit Care Med 2010; 11:12-17
    • (2010) Pediatr Crit Care Med , vol.11 , pp. 12-17
    • Thomas, N.J.1    Shaffer, M.L.2    Willson, D.F.3
  • 11
    • 84886653622 scopus 로고    scopus 로고
    • Correlation of oxygen saturation as measured by pulse oximetry/fraction of inspired oxygen ratio with Pao2/fraction of inspired oxygen ratio in a heterogeneous sample of critically ill children
    • Lobete C, Medina A, Rey C, et al: Correlation of oxygen saturation as measured by pulse oximetry/fraction of inspired oxygen ratio with Pao2/fraction of inspired oxygen ratio in a heterogeneous sample of critically ill children. J Crit Care 2013; 28:538.e1-538.e7
    • (2013) J Crit Care , vol.28 , pp. 538e1-538e7
    • Lobete, C.1    Medina, A.2    Rey, C.3
  • 12
    • 84981272705 scopus 로고    scopus 로고
    • Nonlinear imputation of Pao2/Fio2 from Spo2/Fio2 among patients with acute respiratory distress syndrome
    • NIH/NHLBI PETAL Network Collaborators
    • Brown SM, Grissom CK, Moss M, et al; NIH/NHLBI PETAL Network Collaborators: Nonlinear imputation of Pao2/Fio2 from Spo2/Fio2 among patients with acute respiratory distress syndrome. Chest 2016; 150:307-313
    • (2016) Chest , vol.150 , pp. 307-313
    • Brown, S.M.1    Grissom, C.K.2    Moss, M.3
  • 13
    • 0024429262 scopus 로고
    • Determination of Po2 from saturation
    • Ellis RK: Determination of Po2 from saturation. J Appl Physiol (1985) 1989; 67:902
    • (1989) J Appl Physiol (1985) , vol.67 , pp. 902
    • Ellis, R.K.1
  • 14
    • 0018399378 scopus 로고
    • Simple, accurate equations for human blood O2 dissociation computations
    • Severinghaus JW: Simple, accurate equations for human blood O2 dissociation computations. J Appl Physiol Respir Environ Exerc Physiol 1979; 46:599-602
    • (1979) J Appl Physiol Respir Environ Exerc Physiol , vol.46 , pp. 599-602
    • Severinghaus, J.W.1
  • 15
    • 84873473738 scopus 로고    scopus 로고
    • Mortality, morbidity, and disease severity of patients with aspiration pneumonia
    • Lanspa MJ, Jones BE, Brown SM, et al: Mortality, morbidity, and disease severity of patients with aspiration pneumonia. J Hosp Med 2013; 8:83-90
    • (2013) J Hosp Med , vol.8 , pp. 83-90
    • Lanspa, M.J.1    Jones, B.E.2    Brown, S.M.3
  • 16
    • 83655201385 scopus 로고    scopus 로고
    • Hospital admission decision for patients with community-acquired pneumonia: Variability among physicians in an emergency department
    • Dean NC, Jones JP, Aronsky D, et al: Hospital admission decision for patients with community-acquired pneumonia: Variability among physicians in an emergency department. Ann Emerg Med 2012; 59:35-41
    • (2012) Ann Emerg Med , vol.59 , pp. 35-41
    • Dean, N.C.1    Jones, J.P.2    Aronsky, D.3
  • 17
    • 73349140533 scopus 로고    scopus 로고
    • Validation of the Infectious Disease Society of America/American Thoracic Society 2007 guidelines for severe community-acquired pneumonia
    • Infectious Disease Society of America/American Thoracic Society 2007
    • Brown SM, Jones BE, Jephson AR, et al; Infectious Disease Society of America/American Thoracic Society 2007: Validation of the Infectious Disease Society of America/American Thoracic Society 2007 guidelines for severe community-acquired pneumonia. Crit Care Med 2009; 37:3010-3016
    • (2009) Crit Care Med , vol.37 , pp. 3010-3016
    • Brown, S.M.1    Jones, B.E.2    Jephson, A.R.3
  • 18
    • 84931560153 scopus 로고    scopus 로고
    • Accuracy of Pao2/Fio2 calculated from Spo2 for severity assessment in ED patients with pneumonia
    • Sanz F, Dean N, Dickerson J, et al: Accuracy of Pao2/Fio2 calculated from Spo2 for severity assessment in ED patients with pneumonia. Respirology 2015; 20:813-818
    • (2015) Respirology , vol.20 , pp. 813-818
    • Sanz, F.1    Dean, N.2    Dickerson, J.3
  • 20
    • 85008368392 scopus 로고    scopus 로고
    • Reevaluation of Systemic Early Neuromuscular Blockade Protocol Committee and the National Institutes of Health National Heart, Lung, and Design and rationale of the Reevaluation of Systemic Early Neuromuscular Blockade trial for acute respiratory distress syndrome
    • Blood Institute Prevention and Early Treatment of Acute Lung Injury Network Investigators
    • Huang DT, Angus DC, Moss M, et al; Reevaluation of Systemic Early Neuromuscular Blockade Protocol Committee and the National Institutes of Health National Heart, Lung, and Blood Institute Prevention and Early Treatment of Acute Lung Injury Network Investigators: Design and rationale of the Reevaluation of Systemic Early Neuromuscular Blockade trial for acute respiratory distress syndrome. Ann Am Thorac Soc 2017; 14:124-133
    • (2017) Ann Am Thorac Soc , vol.14 , pp. 124-133
    • Huang, D.T.1    Angus, D.C.2    Moss, M.3
  • 21
    • 77956671058 scopus 로고    scopus 로고
    • Neuromuscular blockers in early acute respiratory distress syndrome
    • ACURASYS Study Investigators
    • Papazian L, Forel JM, Gacouin A, et al; ACURASYS Study Investigators: Neuromuscular blockers in early acute respiratory distress syndrome. N Engl J Med 2010; 363:1107-1116
    • (2010) N Engl J Med , vol.363 , pp. 1107-1116
    • Papazian, L.1    Forel, J.M.2    Gacouin, A.3
  • 22
    • 0023710206 scopus 로고
    • Comparing the areas under two or more correlated receiver operating characteristic curves: A nonparametric approach
    • DeLong ER, DeLong DM, Clarke-Pearson DL: Comparing the areas under two or more correlated receiver operating characteristic curves: A nonparametric approach. Biometrics 1988; 44: 837-845
    • (1988) Biometrics , vol.44 , pp. 837-845
    • DeLong, E.R.1    DeLong, D.M.2    Clarke-Pearson, D.L.3
  • 23
    • 84964927929 scopus 로고    scopus 로고
    • R Development Core Team. Vienna, Austria, R Foundation for Statistical Computing
    • R Development Core Team: R: A Language and Environment for Statistical Computing. Vienna, Austria, R Foundation for Statistical Computing, 2015
    • (2015) R: A Language and Environment for Statistical Computing
  • 24
    • 44349104866 scopus 로고    scopus 로고
    • Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: The effects of oximeter probe type and gender
    • tables of contents
    • Feiner JR, Severinghaus JW, Bickler PE: Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: The effects of oximeter probe type and gender. Anesth Analg 2007; 105(6 Suppl):S18-S23, tables of contents
    • (2007) Anesth Analg , vol.105 , Issue.6 , pp. S18-S23
    • Feiner, J.R.1    Severinghaus, J.W.2    Bickler, P.E.3
  • 25
    • 16244406223 scopus 로고    scopus 로고
    • Effects of skin pigmentation on pulse oximeter accuracy at low saturation
    • Bickler PE, Feiner JR, Severinghaus JW: Effects of skin pigmentation on pulse oximeter accuracy at low saturation. Anesthesiology 2005; 102:715-719
    • (2005) Anesthesiology , vol.102 , pp. 715-719
    • Bickler, P.E.1    Feiner, J.R.2    Severinghaus, J.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.