메뉴 건너뛰기




Volumn 96, Issue , 2017, Pages 213-219

A Point-of-Need infrared mediated PCR platform with compatible lateral flow strip for HPV detection

Author keywords

Infrared LED; Lateral flow strip; Microfluidic; PCR; Point of Need testing

Indexed keywords

CARBON NANOTUBES; CHEMICAL CONTAMINATION; DIAGNOSIS; FOOD SAFETY; MICROFLUIDICS; NANOTUBES; NUCLEIC ACIDS; OILS AND FATS; PESTICIDES; PROPORTIONAL CONTROL SYSTEMS; YARN;

EID: 85019026953     PISSN: 09565663     EISSN: 18734235     Source Type: Journal    
DOI: 10.1016/j.bios.2017.04.047     Document Type: Article
Times cited : (40)

References (25)
  • 2
    • 85019031714 scopus 로고    scopus 로고
    • Point-of-Need Testing: Application of Microfluidic Technologies
    • Benjamin, R., Sébastien, C., 2016. Point-of-Need Testing: Application of Microfluidic Technologies. 〈http://www.i-micronews.com/category-listing/product/point-of-need-testing-application-of-icrofluidic-technologies-2016-report.html?Utm_source=PR&utm_medium=email&utm_campaign=PoN_MarketOverview_Report_Oct2016〉.
    • (2016)
    • Benjamin, R.1    Sébastien, C.2
  • 3
    • 84951800327 scopus 로고    scopus 로고
    • Fluorescence-based biosensor for monitoring of environmental pollutants: from concept to field application
    • Bidmanova, S., Kotlanova, M., Rataj, T., Damborsky, J., Trtilek, M., Prokop, Z., Fluorescence-based biosensor for monitoring of environmental pollutants: from concept to field application. Biosens. Bioelectron. 84 (2016), 97–105.
    • (2016) Biosens. Bioelectron. , vol.84 , pp. 97-105
    • Bidmanova, S.1    Kotlanova, M.2    Rataj, T.3    Damborsky, J.4    Trtilek, M.5    Prokop, Z.6
  • 6
    • 73149111034 scopus 로고    scopus 로고
    • A palmtop PCR system with a disposable polymer chip operated by the thermosiphon effect
    • Chung, K.H., Park, S.H., Choi, Y.H., A palmtop PCR system with a disposable polymer chip operated by the thermosiphon effect. Lab a Chip 10:2 (2010), 202–210.
    • (2010) Lab a Chip , vol.10 , Issue.2 , pp. 202-210
    • Chung, K.H.1    Park, S.H.2    Choi, Y.H.3
  • 7
    • 84918778683 scopus 로고    scopus 로고
    • Development of paper-based color test-strip for drug detection in aquatic environment: application to oxytetracycline
    • Gomes, H.I., Sales, M.G.F., Development of paper-based color test-strip for drug detection in aquatic environment: application to oxytetracycline. Biosens. Bioelectron. 65 (2015), 54–61.
    • (2015) Biosens. Bioelectron. , vol.65 , pp. 54-61
    • Gomes, H.I.1    Sales, M.G.F.2
  • 8
    • 0034332632 scopus 로고    scopus 로고
    • Noncontact infrared-mediated thermocycling for effective polymerase chain reaction amplification of DNA in nanoliter volumes
    • Hühmer, A., Landers, J., Noncontact infrared-mediated thermocycling for effective polymerase chain reaction amplification of DNA in nanoliter volumes. Anal. Chem. 72:21 (2000), 5507–5512.
    • (2000) Anal. Chem. , vol.72 , Issue.21 , pp. 5507-5512
    • Hühmer, A.1    Landers, J.2
  • 9
    • 79954552782 scopus 로고    scopus 로고
    • A valveless microfluidic device for integrated solid phase extraction and polymerase chain reaction for short tandem repeat (STR) analysis
    • Hagan, K.A., Reedy, C.R., Bienvenue, J.M., Dewald, A.H., Landers, J.P., A valveless microfluidic device for integrated solid phase extraction and polymerase chain reaction for short tandem repeat (STR) analysis. Analyst 136:9 (2011), 1928–1937.
    • (2011) Analyst , vol.136 , Issue.9 , pp. 1928-1937
    • Hagan, K.A.1    Reedy, C.R.2    Bienvenue, J.M.3    Dewald, A.H.4    Landers, J.P.5
  • 10
    • 84924192951 scopus 로고    scopus 로고
    • Multiplex diagnosis of viral infectious diseases (AIDS, hepatitis C, and hepatitis A) based on point of care lateral flow assay using engineered proteinticles
    • Lee, J.-H., Seo, H.S., Kwon, J.-H., Kim, H.-T., Kwon, K.C., Sim, S.J., Cha, Y.J., Lee, J., Multiplex diagnosis of viral infectious diseases (AIDS, hepatitis C, and hepatitis A) based on point of care lateral flow assay using engineered proteinticles. Biosens. Bioelectron. 69 (2015), 213–225.
    • (2015) Biosens. Bioelectron. , vol.69 , pp. 213-225
    • Lee, J.-H.1    Seo, H.S.2    Kwon, J.-H.3    Kim, H.-T.4    Kwon, K.C.5    Sim, S.J.6    Cha, Y.J.7    Lee, J.8
  • 11
    • 33644746296 scopus 로고    scopus 로고
    • A simple, valveless microfluidic sample preparation device for extraction and amplification of DNA from nanoliter-volume samples
    • Legendre, L.A., Bienvenue, J.M., Roper, M.G., Ferrance, J.P., Landers, J.P., A simple, valveless microfluidic sample preparation device for extraction and amplification of DNA from nanoliter-volume samples. Anal. Chem. 78:5 (2006), 1444–1451.
    • (2006) Anal. Chem. , vol.78 , Issue.5 , pp. 1444-1451
    • Legendre, L.A.1    Bienvenue, J.M.2    Roper, M.G.3    Ferrance, J.P.4    Landers, J.P.5
  • 12
    • 1842477059 scopus 로고    scopus 로고
    • Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection
    • Liu, R.H., Yang, J., Lenigk, R., Bonanno, J., Grodzinski, P., Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection. Anal. Chem. 76:7 (2004), 1824–1831.
    • (2004) Anal. Chem. , vol.76 , Issue.7 , pp. 1824-1831
    • Liu, R.H.1    Yang, J.2    Lenigk, R.3    Bonanno, J.4    Grodzinski, P.5
  • 13
    • 33745674743 scopus 로고    scopus 로고
    • Ultra fast miniaturized real-time PCR: 40 cycles in less than six minutes
    • (e77)
    • Neuzil, P., Zhang, C., Pipper, J., Oh, S., Zhuo, L., Ultra fast miniaturized real-time PCR: 40 cycles in less than six minutes. Nucleic Acids Res., 34(11), 2006, e77 (e77).
    • (2006) Nucleic Acids Res. , vol.34 , Issue.11 , pp. e77
    • Neuzil, P.1    Zhang, C.2    Pipper, J.3    Oh, S.4    Zhuo, L.5
  • 14
    • 85014586517 scopus 로고    scopus 로고
    • An integrated rotary microfluidic system with DNA extraction, loop-mediated isothermal amplification, and lateral flow strip based detection for point-of-care pathogen diagnostics
    • Park, B.H., Oh, S.J., Jung, J.H., Choi, G., Seo, J.H., Lee, E.Y., Seo, T.S., An integrated rotary microfluidic system with DNA extraction, loop-mediated isothermal amplification, and lateral flow strip based detection for point-of-care pathogen diagnostics. Biosens. Bioelectron., 2016.
    • (2016) Biosens. Bioelectron.
    • Park, B.H.1    Oh, S.J.2    Jung, J.H.3    Choi, G.4    Seo, J.H.5    Lee, E.Y.6    Seo, T.S.7
  • 17
    • 85019026279 scopus 로고    scopus 로고
    • A new lateral flow strip assay (LFSA) using a pair of aptamers for the detection of vaspin
    • Raston, N.H.A., Nguyen, V.-T., Gu, M.B., A new lateral flow strip assay (LFSA) using a pair of aptamers for the detection of vaspin. Biosens. Bioelectron., 2016.
    • (2016) Biosens. Bioelectron.
    • Raston, N.H.A.1    Nguyen, V.-T.2    Gu, M.B.3
  • 18
    • 84958053482 scopus 로고    scopus 로고
    • A fully integrated paperfluidic molecular diagnostic chip for the extraction, amplification, and detection of nucleic acids from clinical samples
    • Rodriguez, N.M., Wong, W.S., Liu, L., Dewar, R., Klapperich, C.M., A fully integrated paperfluidic molecular diagnostic chip for the extraction, amplification, and detection of nucleic acids from clinical samples. Lab a Chip 16:4 (2016), 753–763.
    • (2016) Lab a Chip , vol.16 , Issue.4 , pp. 753-763
    • Rodriguez, N.M.1    Wong, W.S.2    Liu, L.3    Dewar, R.4    Klapperich, C.M.5
  • 19
    • 0035880560 scopus 로고    scopus 로고
    • Photothermal temperature control of a chemical reaction on a microchip using an infrared diode laser
    • Slyadnev, M.N., Tanaka, Y., Tokeshi, M., Kitamori, T., Photothermal temperature control of a chemical reaction on a microchip using an infrared diode laser. Anal. Chem. 73:16 (2001), 4037–4044.
    • (2001) Anal. Chem. , vol.73 , Issue.16 , pp. 4037-4044
    • Slyadnev, M.N.1    Tanaka, Y.2    Tokeshi, M.3    Kitamori, T.4
  • 20
    • 84894047553 scopus 로고    scopus 로고
    • Evaluation of point-of-care testing of C-reactive protein in forensic autopsy cases
    • Soejima, M., Koda, Y., Evaluation of point-of-care testing of C-reactive protein in forensic autopsy cases. Forensic Sci. Int. 237 (2014), 27–29.
    • (2014) Forensic Sci. Int. , vol.237 , pp. 27-29
    • Soejima, M.1    Koda, Y.2
  • 21
    • 84984832870 scopus 로고    scopus 로고
    • Rapid real-time PCR and high resolution melt analysis in a self-filling thermoplastic chip
    • Sposito, A., Hoang, V., DeVoe, D., Rapid real-time PCR and high resolution melt analysis in a self-filling thermoplastic chip. Lab a Chip 16:18 (2016), 3524–3531.
    • (2016) Lab a Chip , vol.16 , Issue.18 , pp. 3524-3531
    • Sposito, A.1    Hoang, V.2    DeVoe, D.3
  • 23
    • 84855810415 scopus 로고    scopus 로고
    • Paper-based three-dimensional electrochemical immunodevice based on multi-walled carbon nanotubes functionalized paper for sensitive point-of-care testing
    • Wang, P., Ge, L., Yan, M., Song, X., Ge, S., Yu, J., Paper-based three-dimensional electrochemical immunodevice based on multi-walled carbon nanotubes functionalized paper for sensitive point-of-care testing. Biosens. Bioelectron. 32:1 (2012), 238–243.
    • (2012) Biosens. Bioelectron. , vol.32 , Issue.1 , pp. 238-243
    • Wang, P.1    Ge, L.2    Yan, M.3    Song, X.4    Ge, S.5    Yu, J.6
  • 24
    • 84981332696 scopus 로고    scopus 로고
    • 3D origami electrochemical device for sensitive Pb 2+ testing based on DNA functionalized iron-porphyrinic metal-organic framework
    • Wang, X., Yang, C., Zhu, S., Yan, M., Ge, S., Yu, J., 3D origami electrochemical device for sensitive Pb 2+ testing based on DNA functionalized iron-porphyrinic metal-organic framework. Biosens. Bioelectron. 87 (2017), 108–115.
    • (2017) Biosens. Bioelectron. , vol.87 , pp. 108-115
    • Wang, X.1    Yang, C.2    Zhu, S.3    Yan, M.4    Ge, S.5    Yu, J.6
  • 25
    • 84897147643 scopus 로고    scopus 로고
    • Rapid identification of H5 avian influenza virus in chicken throat swab specimens using microfluidic real-time RT-PCR
    • Zhu, L., Zhu, C., Deng, G., Zhang, L., Zhao, S., Lin, J., Li, L., Jiao, P., Liao, M., Liu, Y., Rapid identification of H5 avian influenza virus in chicken throat swab specimens using microfluidic real-time RT-PCR. Anal. Methods 6:8 (2014), 2628–2632.
    • (2014) Anal. Methods , vol.6 , Issue.8 , pp. 2628-2632
    • Zhu, L.1    Zhu, C.2    Deng, G.3    Zhang, L.4    Zhao, S.5    Lin, J.6    Li, L.7    Jiao, P.8    Liao, M.9    Liu, Y.10