메뉴 건너뛰기




Volumn 64, Issue 3, 2017, Pages 2092-2101

Dynamic Performance Improvement of a Grid-Tied PV System Using a Feed-Forward Control Loop Acting on the NPC Inverter Currents

Author keywords

Active power line conditioning; feed forward control loop (FFCL); photovoltaic (PV) system; three level neutral point clamped (NPC) inverter

Indexed keywords

CLOSED LOOP CONTROL SYSTEMS; DIGITAL SIGNAL PROCESSORS; ELECTRIC INVERTERS; ELECTRIC POWER TRANSMISSION NETWORKS; PHOTOVOLTAIC CELLS; SIGNAL PROCESSING;

EID: 85015057027     PISSN: 02780046     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIE.2016.2625779     Document Type: Article
Times cited : (73)

References (24)
  • 1
    • 26844560797 scopus 로고    scopus 로고
    • A review of singlephase grid-connected inverters for photovoltaic modules
    • Sep./Oct.
    • S. B. Kjaer, J. K. Pedersen, and F. Blaabjerg, "A review of singlephase grid-connected inverters for photovoltaic modules," IEEE Trans. Ind. Appl., vol. 41, no. 5, pp. 1292-1306, Sep./Oct. 2005.
    • (2005) IEEE Trans. Ind. Appl. , vol.41 , Issue.5 , pp. 1292-1306
    • Kjaer, S.B.1    Pedersen, J.K.2    Blaabjerg, F.3
  • 2
    • 84860844734 scopus 로고    scopus 로고
    • Design and control of a grid-connected three-phase 3-level NPC inverter for building integrated photovoltaic systems
    • Washington, DC, USA
    • Y. Kim, H. Cha, B. M. Song, and K. Y. Lee, "Design and control of a grid-connected three-phase 3-level NPC inverter for building integrated photovoltaic systems," in Proc. IEEE PES Innovative SmartGrid Technol., Washington, DC, USA, 2012, pp. 1-7.
    • (2012) Proc. IEEE PES Innovative SmartGrid Technol. , pp. 1-7
    • Kim, Y.1    Cha, H.2    Song, B.M.3    Lee, K.Y.4
  • 3
    • 84939455769 scopus 로고    scopus 로고
    • Reactive power control of three-phase grid-connected PV system during grid faults using Takagi-Sugeno-Kang probabilistic fuzzy neural network control
    • Sep.
    • F. J. Lin, K. C. Lu, T. H. Ke, B. H. Yang, and Y. R. Chang, "Reactive power control of three-phase grid-connected PV system during grid faults using Takagi-Sugeno-Kang probabilistic fuzzy neural network control," IEEE Trans. Ind. Electron., vol. 62, no. 9, pp. 5516-5528, Sep. 2015.
    • (2015) IEEE Trans. Ind. Electron. , vol.62 , Issue.9 , pp. 5516-5528
    • Lin, F.J.1    Lu, K.C.2    Ke, T.H.3    Yang, B.H.4    Chang, Y.R.5
  • 4
    • 84934312185 scopus 로고    scopus 로고
    • MPPT with single DC-DC converter and inverter for grid-connected hybrid wind-driven PMSG-PV system
    • Aug.
    • M. M. R. Singaravel and S. A. Daniel, "MPPT with single DC-DC converter and inverter for grid-connected hybrid wind-driven PMSG-PV system," IEEE Trans. Ind. Electron., vol. 62, no. 8, pp. 4849-4857, Aug. 2015.
    • (2015) IEEE Trans. Ind. Electron. , vol.62 , Issue.8 , pp. 4849-4857
    • Singaravel, M.M.R.1    Daniel, S.A.2
  • 5
    • 67650697138 scopus 로고    scopus 로고
    • A Control methodology and characterization of dynamics for a photovoltaic (PV) system interfaced with a distribution network
    • Jul.
    • A. Yazdani and P. P. Dash, "A Control methodology and characterization of dynamics for a photovoltaic (PV) system interfaced with a distribution network," IEEE Trans. Power Del., vol. 24, no. 3, pp. 1538-1551, Jul. 2009.
    • (2009) IEEE Trans. Power Del. , vol.24 , Issue.3 , pp. 1538-1551
    • Yazdani, A.1    Dash, P.P.2
  • 6
    • 84966276127 scopus 로고    scopus 로고
    • Single-phase grid-connected photovoltaic system with active power line conditioning
    • Feb.
    • S. A. O. Silva, L. B. G. Campanhol, V. D. Bacon, and L. P. Sampaio, "Single-phase grid-connected photovoltaic system with active power line conditioning," Brazilian Power Electron. J., vol. 20, no. 1, pp. 8-18, Feb. 2015.
    • (2015) Brazilian Power Electron. J. , vol.20 , Issue.1 , pp. 8-18
    • Silva, S.A.O.1    Campanhol, L.B.G.2    Bacon, V.D.3    Sampaio, L.P.4
  • 7
    • 84969567902 scopus 로고    scopus 로고
    • Grid-tied photovoltaic system based on PSO MPPT technique with active power line conditioning
    • Apr.
    • F. M. Oliveira, S. A. O. Silva, F. R. Durand, L. P. Sampaio, V. D. Bacon, and L. B. G. Campanhol, "Grid-tied photovoltaic system based on PSO MPPT technique with active power line conditioning," IET Power Electron., vol. 9, no. 6, pp. 1180-1191, Apr. 2016.
    • (2016) IET Power Electron. , vol.9 , Issue.6 , pp. 1180-1191
    • Oliveira, F.M.1    Silva, S.A.O.2    Durand, F.R.3    Sampaio, L.P.4    Bacon, V.D.5    Campanhol, L.B.G.6
  • 8
    • 80053633990 scopus 로고    scopus 로고
    • Eliminating leakage currents in neutral point clamped inverters for photovoltaic systems
    • Oct.
    • M. C. Cavalcanti, A. M. Farias, K. C. Oliveira, F. A. S. Neves, and J. L. Afonso, "Eliminating leakage currents in neutral point clamped inverters for photovoltaic systems," IEEE Trans. Ind. Electron., vol. 59, no. 1, pp. 435-443, Oct. 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.59 , Issue.1 , pp. 435-443
    • Cavalcanti, M.C.1    Farias, A.M.2    Oliveira, K.C.3    Neves, F.A.S.4    Afonso, J.L.5
  • 10
    • 84930506376 scopus 로고    scopus 로고
    • Topology review and derivation methodology of single-phase transformerless photovoltaic inverters for leakage current suppression
    • Jul.
    • W. Li, Y. Gu, H. Luo, W. Cui, X. He, and C. Xia, "Topology review and derivation methodology of single-phase transformerless photovoltaic inverters for leakage current suppression," IEEE Trans. Ind. Electron., vol. 62, no. 7, pp. 4537-4551, Jul. 2015.
    • (2015) IEEE Trans. Ind. Electron. , vol.62 , Issue.7 , pp. 4537-4551
    • Li, W.1    Gu, Y.2    Luo, H.3    Cui, W.4    He, X.5    Xia, C.6
  • 11
    • 84962449703 scopus 로고    scopus 로고
    • Highly reliable transformerless photovoltaic inverterswith leakage current and pulsating power elimination
    • Feb.
    • Y. Tang, W. Yao, P. C. Loh, and F. Blaabjerg, "Highly reliable transformerless photovoltaic inverterswith leakage current and pulsating power elimination," IEEE Trans. Ind. Electron., vol. 63, no. 2, pp. 1016-1026, Feb. 2016.
    • (2016) IEEE Trans. Ind. Electron. , vol.63 , Issue.2 , pp. 1016-1026
    • Tang, Y.1    Yao, W.2    Loh, P.C.3    Blaabjerg, F.4
  • 12
    • 37749035348 scopus 로고    scopus 로고
    • A single-stage three-phase grid-connected photovoltaic system with modified MPPT method and reactive power compensation
    • Dec.
    • W. Libo, Z. Zhengming, and L. Jianzheng, "A single-stage three-phase grid-connected photovoltaic system with modified MPPT method and reactive power compensation," IEEE Trans. Power Electron., vol. 22, no. 4, pp. 881-886, Dec. 2007.
    • (2007) IEEE Trans. Power Electron. , vol.22 , Issue.4 , pp. 881-886
    • Libo, W.1    Zhengming, Z.2    Jianzheng, L.3
  • 13
    • 84949604230 scopus 로고    scopus 로고
    • A functionbased maximum power point tracking method for photovoltaic systems
    • Mar.
    • S. M. Reza Touse, M. H. Moradi, N. S. Basir, and M. Nemati, "A functionbased maximum power point tracking method for photovoltaic systems," IEEE Trans. Power Electron., vol. 31, no. 3, pp. 2120-2128, Mar. 2016.
    • (2016) IEEE Trans. Power Electron. , vol.31 , Issue.3 , pp. 2120-2128
    • Reza Touse, S.M.1    Moradi, M.H.2    Basir, N.S.3    Nemati, M.4
  • 14
    • 84860306939 scopus 로고    scopus 로고
    • An improved particle swarm optimization (PSO)-based MPPT for PV with reduced steady-state oscillation
    • Aug.
    • K. Ishaque, Z. Salam, M. Amiad, and S. Mekhilef, "An improved particle swarm optimization (PSO)-based MPPT for PV with reduced steady-state oscillation," IEEE Trans. Power Electron., vol. 27, no. 8, pp. 3627-3638, Aug. 2012.
    • (2012) IEEE Trans. Power Electron. , vol.27 , Issue.8 , pp. 3627-3638
    • Ishaque, K.1    Salam, Z.2    Amiad, M.3    Mekhilef, S.4
  • 15
    • 84868143067 scopus 로고    scopus 로고
    • Evaluation of the main MPPT techniques for photovoltaic applications
    • Mar.
    • M. A. G. Brito, L. Galotto, L. P. Sampaio, G. A.Melo, and C. A. Canesin, "Evaluation of the main MPPT techniques for photovoltaic applications," IEEE Trans. Ind. Electron., vol. 60, no. 3, pp. 1156-1167, Mar. 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.3 , pp. 1156-1167
    • Brito, M.A.G.1    Galotto, L.2    Sampaio, L.P.3    Melo, G.A.4    Canesin, C.A.5
  • 17
    • 84893555742 scopus 로고    scopus 로고
    • Three-phase power controlled PV current source inverter with incorporated active power filtering
    • Vienna, Austria
    • T. Geury, S. Pinto, and J. Gyselinck, "Three-phase power controlled PV current source inverter with incorporated active power filtering," in Proc. 39th IEEE Ind. Electron. Conf., Vienna, Austria, 2013, pp. 1374-1379.
    • (2013) Proc. 39th IEEE Ind. Electron. Conf. , pp. 1374-1379
    • Geury, T.1    Pinto, S.2    Gyselinck, J.3
  • 18
    • 84887076211 scopus 로고    scopus 로고
    • Simplified reactive power control for single-phase grid-connected photovoltaic inverters
    • May
    • C. H. Chang, Y. H. Lin, Y. M. Chen, and Y. R. Chang, "Simplified reactive power control for single-phase grid-connected photovoltaic inverters," IEEE Trans. Ind. Electron., vol. 61, no. 5, pp. 2286-2296, May 2014.
    • (2014) IEEE Trans. Ind. Electron. , vol.61 , Issue.5 , pp. 2286-2296
    • Chang, C.H.1    Lin, Y.H.2    Chen, Y.M.3    Chang, Y.R.4
  • 20
    • 84920520369 scopus 로고    scopus 로고
    • A three-phase three-level NPC inverter based grid-connected photovoltaic system with active power filtering
    • Antalya, Turkey
    • S. Sezen, A. Aktas, M. Ucar, and E. Ozdemir, "A three-phase three-level NPC inverter based grid-connected photovoltaic system with active power filtering," in Proc. 16th Int. Power Electron. Motion Control Conf. Expo., Antalya, Turkey, 2014, pp. 1331-1335.
    • (2014) Proc. 16th Int. Power Electron. Motion Control Conf. Expo. , pp. 1331-1335
    • Sezen, S.1    Aktas, A.2    Ucar, M.3    Ozdemir, E.4
  • 21
    • 84947067974 scopus 로고    scopus 로고
    • Performance improvement of a threephase phase-locked-loop algorithm under utility voltage disturbances using non-autonomous adaptive filters
    • Nov.
    • V. D. Bacon and S. A. O. Silva, "Performance improvement of a threephase phase-locked-loop algorithm under utility voltage disturbances using non-autonomous adaptive filters," IET Power Electron., vol. 8, no. 11, pp. 2237-2250, Nov. 2015.
    • (2015) IET Power Electron. , vol.8 , Issue.11 , pp. 2237-2250
    • Bacon, V.D.1    Silva, S.A.O.2
  • 23
    • 84908159067 scopus 로고    scopus 로고
    • Proportional-integral/proportional-integral-derivative tuning procedure of a singlephase shunt active power filter using Bode diagram
    • Aug.
    • B. A. Angélico, L. B. G. Campanhol, and S. A. O. Silva, "Proportional-integral/proportional-integral-derivative tuning procedure of a singlephase shunt active power filter using Bode diagram," IET Power Electron., vol. 7, no. 10, pp. 2647-2659, Aug. 2014.
    • (2014) IET Power Electron. , vol.7 , Issue.10 , pp. 2647-2659
    • Angélico, B.A.1    Campanhol, L.B.G.2    Silva, S.A.O.3
  • 24
    • 84909636704 scopus 로고    scopus 로고
    • Application of shunt active power filter for harmonic reduction and reactive power compensation in three-phase four-wire systems
    • Nov.
    • L. B. G. Campanhol, S. A. O. Silva, and A. Goedtel, "Application of shunt active power filter for harmonic reduction and reactive power compensation in three-phase four-wire systems," IET Power Electron., vol. 7, no. 11, pp. 2825-2836, Nov. 2014.
    • (2014) IET Power Electron. , vol.7 , Issue.11 , pp. 2825-2836
    • Campanhol, L.B.G.1    Silva, S.A.O.2    Goedtel, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.