메뉴 건너뛰기




Volumn 41, Issue , 2004, Pages 136-139

Evaluation of s values for beta-ray emitters within the urinary bladder

Author keywords

Beta ray emitter; MIRD phantom; Monte Carlo simulation; S value; Urinary bladder; Voxel phantom

Indexed keywords


EID: 85010628594     PISSN: 00223131     EISSN: None     Source Type: Journal    
DOI: 10.1080/00223131.2004.10875664     Document Type: Article
Times cited : (6)

References (17)
  • 3
    • 0041895025 scopus 로고
    • Pergamon Press
    • ICRR Limits for Intakes of Radionuclides by Workers. ICRP Publication 30. Pergamon Press (1979).
    • (1979) ICRP Publication 30
  • 4
    • 0026629393 scopus 로고
    • MIRD Pamphlet No. 14: A Dynamic urinary Bladder Model for Radiation Dose Calculations
    • S. R. Thomas, M. G Stabin, C-T. Chen, R. C. Samaratunga. MIRD Pamphlet No. 14: A Dynamic urinary Bladder Model for Radiation Dose Calculations, J Nucl Med. 33 (5), 783-802 (1992).
    • (1992) J Nucl Med. , vol.33 , Issue.5 , pp. 783-802
    • Thomas, S.R.1    Stabin, M.G.2    Chen, C.-T.3    Samaratunga, R.C.4
  • 5
    • 0032937790 scopus 로고    scopus 로고
    • MIRD Pamphlet No. 14 Revised: A Dynamic urinary Bladder Model for Radiation Dose Calculations
    • S. R. Thomas, M. G Stabin, C-T. Chen, R. C. Samaratunga, MIRD Pamphlet No. 14 Revised: A Dynamic urinary Bladder Model for Radiation Dose Calculations, J Nucl Med. 40 (4), 102S-123S (1999).
    • (1999) J Nucl Med , vol.40 , Issue.4 , pp. 102S-123S
    • Thomas, S.R.1    Stabin, M.G.2    Chen, C.-T.3    Samaratunga, R.C.4
  • 6
    • 0031797970 scopus 로고    scopus 로고
    • Radiation Absorbed Doses to the Walls ofHoIlow Organs
    • J. B. Stubbs, J. F. Evans and M. G Stabin, Radiation Absorbed Doses to the Walls ofHoIlow Organs, J Nucl Med. 39 (11), 1989-1995 (1998)
    • (1998) J Nucl Med. , vol.39 , Issue.11 , pp. 1989-1995
    • Stubbs, J.B.1    Evans, J.F.2    Stabin, M.G.3
  • 7
    • 4243362726 scopus 로고    scopus 로고
    • Evaluation of Fluence to Dose Equivalent Conversion Coefficients for High Energy Photons
    • (in Japanese)
    • S. Iwai, O. Sato and S. Tanaka, Evaluation of Fluence to Dose Equivalent Conversion Coefficients for High Energy Photons, KEK Proceedings 93-15, 10-53 (in Japanese).
    • KEK Proceedings 93-15 , pp. 10-53
    • Iwai, S.1    Sato, O.2    Tanaka, S.3
  • 8
    • 0035014195 scopus 로고    scopus 로고
    • Construction of a Computed Tomographic Phantom for a Japanese Male Adult and Dose Calculation System
    • K Saito, A Wttmann, S. Koga, Y Ida, T. Kamei, J. Funabiki and M. Zankl, Construction of a Computed Tomographic Phantom for a Japanese Male Adult and Dose Calculation System, Radial. Environ. Biophys. 40, 69-76 (2001).
    • (2001) Radial. Environ. Biophys. , vol.40 , pp. 69-76
    • Saito, K.1    Wttmann, A.2    Koga, S.3    Ida, Y.4    Kamei, T.5    Funabiki, J.6    Zankl, M.7
  • 9
    • 85010573011 scopus 로고    scopus 로고
    • under preparation
    • K. Saito, under preparation.
    • Saito, K.1
  • 11
    • 0141498009 scopus 로고    scopus 로고
    • Evaluation of Specific Absorbed Fractions in Voxel Phantoms using Monte Carlo Simulation
    • S. Kinase, M. Zankl, J. Kuwabara, K. Sato, H Noguchi, J. Funabiki and K. Saito, Evaluation of Specific Absorbed Fractions in Voxel Phantoms using Monte Carlo Simulation, Radial Prot. Dosim. 105 (1-4), 557-563 (2003).
    • (2003) Radial Prot. Dosim. , vol.105 , Issue.1-4 , pp. 557-563
    • Kinase, S.1    Zankl, M.2    Kuwabara, J.3    Sato, K.4    Noguchi, H.5    Funabiki, J.6    Saito, K.7
  • 16
  • 17
    • 0005180167 scopus 로고    scopus 로고
    • Photon Cross Section Data PHOTX for PEGS4
    • (in Japanese)
    • Y. Sakamoto, Photon Cross Section Data PHOTX for PEGS4, KEK Proceedings 93-15, 77-82 (in Japanese).
    • KEK Proceedings 93-15 , pp. 77-82
    • Sakamoto, Y.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.