메뉴 건너뛰기




Volumn 41, Issue , 2004, Pages 310-313

Uniform Irradiation using Rotational-linear Scanning Method for Narrow Synchrotron Radiation Beam

Author keywords

Dose; Ionization chamber; SPring 8; Synchrotron radiation; TLB; Uniform irradiation

Indexed keywords


EID: 85010575499     PISSN: 00223131     EISSN: None     Source Type: Journal    
DOI: 10.1080/00223131.2004.10875708     Document Type: Article
Times cited : (4)

References (8)
  • 1
    • 0027723118 scopus 로고
    • Responses of LiF TLDs to 10-40 keV monoenergetic photons from Synchrotron radiation
    • N. Nariyama, S. Tanaka, M. Yoshizawa, et al, “Responses of LiF TLDs to 10-40 keV monoenergetic photons from Synchrotron radiation,” Radiat. Prot. Dosim. 49, 451 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.49 , pp. 451
    • Nariyama, N.1    Tanaka, S.2    Yoshizawa, M.3
  • 2
    • 2242459626 scopus 로고    scopus 로고
    • Low-energy x-ray dosimetry studies (7 to 17.5 keV) with synchrotron radiation
    • N.E. Ipe, H. Bellamy, J.R. Flood, et al., “Low-energy x-ray dosimetry studies (7 to 17.5 keV) with synchrotron radiation,” Radiat. Prot. Dosim. 66, 69 (1996).
    • (1996) Radiat. Prot. Dosim. , vol.66 , pp. 69
    • Ipe, N.E.1    Bellamy, H.2    Flood, J.R.3
  • 3
    • 0031773177 scopus 로고    scopus 로고
    • Dose response of various radiation detectors to synchrotron radiation
    • T. Krön, L. Duggan, T. Smith, et al. “Dose response of various radiation detectors to synchrotron radiation,” Phys. Med. Biol. 43, 3235 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 3235
    • Krön, T.1    Duggan, L.2    Smith, T.3
  • 4
    • 0032794348 scopus 로고    scopus 로고
    • Modelling of the thermoluminescence response of LiF:Mg, Cu, P (MCP-N) detectors after doses of low energy photons
    • P. Olko, P. Bilski, M. Budzanowski, et al, “Modelling of the thermoluminescence response of LiF:Mg, Cu, P (MCP-N) detectors after doses of low energy photons,” Radiat. Prot. Dosim. 84, 103 (1999).
    • (1999) Radiat. Prot. Dosim. , vol.84 , pp. 103
    • Olko, P.1    Bilski, P.2    Budzanowski, M.3
  • 7
    • 85010526396 scopus 로고    scopus 로고
    • Private communication
    • S. Ban, Private communication
    • Ban, S.1
  • 8
    • 0034745486 scopus 로고    scopus 로고
    • Dose measurements in inhomogeneous bone/tissue and lung/tissue phantoms for angiography using synchrotron radiation
    • N. Nariyama, Y. Namito, S. Ban, et al. “Dose measurements in inhomogeneous bone/tissue and lung/tissue phantoms for angiography using synchrotron radiation,” Phys. Med. Biol. 46, 717 (2001).
    • (2001) Phys. Med. Biol. , vol.46 , pp. 717
    • Nariyama, N.1    Namito, Y.2    Ban, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.