메뉴 건너뛰기




Volumn 45, Issue 4, 2017, Pages 354-359

Methodology for analyzing environmental quality indicators in a dynamic operating room environment

Author keywords

Air changes per hour; Air quality in operating rooms; Environmental quality indicator (EQI); Mock surgical procedures; Operating room ventilation rates; Surgical site infections

Indexed keywords

AIR QUALITY; ARTICLE; COLONY FORMING UNIT; ENVIRONMENTAL TEMPERATURE; HOSPITAL; HUMAN; HUMIDITY; OPERATING ROOM; OPERATING TABLE; PARTICLE SIZE; PATHOGEN LOAD; AIR POLLUTION; INFECTION CONTROL; MICROBIOLOGY; PROCEDURES;

EID: 85008146698     PISSN: 01966553     EISSN: 15273296     Source Type: Journal    
DOI: 10.1016/j.ajic.2016.11.001     Document Type: Article
Times cited : (32)

References (12)
  • 1
    • 84889582557 scopus 로고    scopus 로고
    • Health care-associated infections a meta-analysis of costs and financial impacts on the US health care system
    • 1 Zimlichman, E., Health care-associated infections a meta-analysis of costs and financial impacts on the US health care system. JAMA Intern Med 173 (2013), 2039–2046.
    • (2013) JAMA Intern Med , vol.173 , pp. 2039-2046
    • Zimlichman, E.1
  • 3
    • 85016477678 scopus 로고
    • Section 3025 of the Affordable Care Act added section (q) to the Social Security Act establishing the Hospital Readmissions Reduction Program, which requires CMS to reduce payments to IPPS hospitals with excess readmissions, effective for discharges beginning on October 1, 2012. The regulations that implement this provision are in subpart I of 42 CFR part 412 (§412.150 through §412.154). 2012.
    • 3 Section 3025 of the Affordable Care Act added section 1886(q) to the Social Security Act establishing the Hospital Readmissions Reduction Program, which requires CMS to reduce payments to IPPS hospitals with excess readmissions, effective for discharges beginning on October 1, 2012. The regulations that implement this provision are in subpart I of 42 CFR part 412 (§412.150 through §412.154). 2012.
    • (1886)
  • 4
    • 84864769067 scopus 로고    scopus 로고
    • Role of Air Changes per hour (ACH) in possible transmission of airborne infections
    • 4 Memarzadeh, F., Weiren, X.U., Role of Air Changes per hour (ACH) in possible transmission of airborne infections. Build Simul 5 (2012), 15–28.
    • (2012) Build Simul , vol.5 , pp. 15-28
    • Memarzadeh, F.1    Weiren, X.U.2
  • 5
    • 33847012687 scopus 로고    scopus 로고
    • Air-treatment systems for controlling hospital acquired infections
    • 5 Kowalski, W.J., Air-treatment systems for controlling hospital acquired infections. HPAC Eng 79 (2007), 24–48.
    • (2007) HPAC Eng , vol.79 , pp. 24-48
    • Kowalski, W.J.1
  • 6
    • 84929516208 scopus 로고    scopus 로고
    • Air contamination for predicting wound contamination in clean surgery: a large multicenter study
    • 6 Birgand, G., Air contamination for predicting wound contamination in clean surgery: a large multicenter study. Am J Infect Control, 2015, 1–6.
    • (2015) Am J Infect Control , pp. 1-6
    • Birgand, G.1
  • 7
    • 85016472734 scopus 로고    scopus 로고
    • HPAC engineering
    • Heating/Piping/Air Conditioning New York
    • 7 English, T., HPAC engineering. 2016, Heating/Piping/Air Conditioning, New York.
    • (2016)
    • English, T.1
  • 8
    • 79955595432 scopus 로고    scopus 로고
    • Long-term surveillance of air quality in medical center operating rooms
    • 8 Wan, G.-H., Chung, F.-F., Tang, C.-S., Long-term surveillance of air quality in medical center operating rooms. Am J Infect Control 39 (2011), 302–308.
    • (2011) Am J Infect Control , vol.39 , pp. 302-308
    • Wan, G.-H.1    Chung, F.-F.2    Tang, C.-S.3
  • 9
    • 0036594291 scopus 로고    scopus 로고
    • Environmental controls in operating theatres
    • 9 Dharan, S., Pittet, D., Environmental controls in operating theatres. J Hosp Infect 51 (2002), 79–84.
    • (2002) J Hosp Infect , vol.51 , pp. 79-84
    • Dharan, S.1    Pittet, D.2
  • 10
    • 0036457837 scopus 로고    scopus 로고
    • Comparison of operating room ventilation in the protection of the surgical site
    • 10 Memarzadeh, F., Manning, A., Comparison of operating room ventilation in the protection of the surgical site. ASHRAE Trans, 108, 2002.
    • (2002) ASHRAE Trans , vol.108
    • Memarzadeh, F.1    Manning, A.2
  • 11
    • 84962643622 scopus 로고    scopus 로고
    • USP 797 pharmaceutical compounding—sterile preparations
    • Rockville (MD)
    • 11 United States Pharmacopeia Society, USP 797 pharmaceutical compounding—sterile preparations. 2008 Rockville (MD).
    • (2008)
    • United States Pharmacopeia Society1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.