메뉴 건너뛰기




Volumn 10, Issue 1, 2010, Pages 110-113

Development of an Individual Device for Exhaled Breath Temperature Measurement

Author keywords

Airway inflammation; clinical annlications; core body temperature; exhaled breath temperature; thermometry

Indexed keywords


EID: 85008006357     PISSN: 1530437X     EISSN: 15581748     Source Type: Journal    
DOI: 10.1109/JSEN.2009.2035732     Document Type: Article
Times cited : (17)

References (12)
  • 2
    • 33845333350 scopus 로고    scopus 로고
    • Perioperative thermoregulation and temperature monitoring
    • S. R. Insler and D. I. Sessler, “Perioperative thermoregulation and temperature monitoring,” Anesthesiology Clin., vol. 24, pp. 823–837, 2006.
    • (2006) Anesthesiology Clin. , vol.24 , pp. 823-837
    • Insler, S.R.1    Sessler, D.I.2
  • 3
    • 0036092075 scopus 로고    scopus 로고
    • Normal oral, rectal, tympanic and axillary body temperature in adult men and women: A systematic literature review
    • M. Sund-Levander, C. Forsberg, and L. K. Wahren, “Normal oral, rectal, tympanic and axillary body temperature in adult men and women: A systematic literature review,” Scand J. Caring Sci., vol. 16, no. 2, pp. 122–128, 2002.
    • (2002) Scand J. Caring Sci. , vol.16 , Issue.2 , pp. 122-128
    • Sund-Levander, M.1    Forsberg, C.2    Wahren, L.K.3
  • 4
    • 0037080554 scopus 로고    scopus 로고
    • Faster rise of EBT in asthma: A novel marker of airway inflammation?
    • P. Paredi, S. A. Kharitonov, and P. J. Barnes, “Faster rise of EBT in asthma: A novel marker of airway inflammation?,” Amer. J. Respir. Crit. Care Med., vol. 165, pp. 181–184, 2002.
    • (2002) Amer. J. Respir. Crit. Care Med. , vol.165 , pp. 181-184
    • Paredi, P.1    Kharitonov, S.A.2    Barnes, P.J.3
  • 6
    • 25444532515 scopus 로고    scopus 로고
    • Correlation of exhaled breath temperature with bronchial blood flow in asthma
    • P. Paredi, S. A. Kharitonov, and P. J. Barnes, “Correlation of exhaled breath temperature with bronchial blood flow in asthma,” Respir. Res., vol. 6, no. 15, pp. 1–10, 2005.
    • (2005) Respir. Res. , vol.6 , Issue.15 , pp. 1-10
    • Paredi, P.1    Kharitonov, S.A.2    Barnes, P.J.3
  • 9
    • 34548237691 scopus 로고    scopus 로고
    • Evaluation of a simple, potentially individual device for exhaled breath temperature measurement
    • T. A. Popov, S. Dunev, T. Z. Kralimarkova, S. Kraeva, and L. M. DuBuske, “Evaluation of a simple, potentially individual device for exhaled breath temperature measurement,” Respir. Med., vol. 101, pp. 2044–2050, 2007.
    • (2007) Respir. Med. , vol.101 , pp. 2044-2050
    • Popov, T.A.1    Dunev, S.2    Kralimarkova, T.Z.3    Kraeva, S.4    DuBuske, L.M.5
  • 10
    • 85008039962 scopus 로고    scopus 로고
    • Ability of an Individual device for measurement of the temperature of exhaled breath to detect changes in patients recovering from mild exacerbations of asthma
    • Berlin, Germany
    • T. Kralimarkova, C. Lazarova, V. Dimitrov, and T. A. Popov, “Ability of an Individual device for measurement of the temperature of exhaled breath to detect changes in patients recovering from mild exacerbations of asthma,” in Proc. ERS, Berlin, Germany, 2008, p. 186s.
    • (2008) Proc. ERS , pp. 186s
    • Kralimarkova, T.1    Lazarova, C.2    Dimitrov, V.3    Popov, T.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.