메뉴 건너뛰기




Volumn 16, Issue 1, 2007, Pages 654-657

Treating drop-foot in hemiplegics: The role of matrix electrode

Author keywords

Dropfoot; Functional electrical stimulation (FES); Functional electrical therapy (FET); Hemiplegia; Intelligent matrix electrode

Indexed keywords

DROPS; FUNCTIONAL ELECTRIC STIMULATION; MECHANICAL VARIABLES MEASUREMENT; MUSCLE;

EID: 85007106623     PISSN: 16800737     EISSN: 14339277     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-540-73044-6_170     Document Type: Conference Paper
Times cited : (9)

References (14)
  • 1
    • 33846038238 scopus 로고    scopus 로고
    • An implantable neuroprostheses for standing and walking in paraplegia: 5-year patient follow-up
    • Guiraud D., Stieglitz T., Koch K.P, Divoux J.L. and Rabischong P. (2006) An implantable neuroprostheses for standing and walking in paraplegia: 5-year patient follow-up. J. Neural Eng. 3:268-275.
    • (2006) J. Neural Eng , vol.3 , pp. 268-275
    • Guiraud, D.1    Stieglitz, T.2    Koch, K.P.3    Divoux, J.L.4    Rabischong, P.5
  • 2
    • 33846086944 scopus 로고    scopus 로고
    • Original electronic design to perform epimysial and neural stimulation in paraplegia
    • Guiraud D., Stieglitz T., Taroni G. and Divoux J.L (2006) Original electronic design to perform epimysial and neural stimulation in paraplegia. J. Neural Eng. 3:276-286.
    • (2006) J. Neural Eng , vol.3 , pp. 276-286
    • Guiraud, D.1    Stieglitz, T.2    Taroni, G.3    Divoux, J.L.4
  • 3
    • 0345099656 scopus 로고    scopus 로고
    • Modified implanted drop foot stimulator system with graphical user interface for customised stimulation pulse-width profiles
    • O’Halloran T., Haugland M., Lyons G., and Sinkjaer, T. (2003) Modified implanted drop foot stimulator system with graphical user interface for customised stimulation pulse-width profiles. Medical & Biological Engineering & Computing, 41(6):701-709.
    • (2003) Medical & Biological Engineering & Computing , vol.41 , Issue.6 , pp. 701-709
    • O’Halloran, T.1    Haugland, M.2    Lyons, G.3    Sinkjaer, T.4
  • 7
    • 58049136262 scopus 로고    scopus 로고
    • Development of a new FES system with trained Super-Multichannel Surface electrodes
    • Bournemouth, UK, September
    • Fujii T., Seki K. and Handa Y. (2004) Development of a new FES system with trained Super-Multichannel Surface electrodes. 9th Annual Conference of the International FES Society, Bournemouth, UK, September.
    • (2004) 9Th Annual Conference of the International FES Society
    • Fujii, T.1    Seki, K.2    Handa, Y.3
  • 9
    • 34047126464 scopus 로고    scopus 로고
    • Transcutaneous Electrical Stimulation Technology for Functional Electrical Therapy Applications
    • USA, August
    • Popovic M.R. (2006) Transcutaneous Electrical Stimulation Technology for Functional Electrical Therapy Applications. 28th IEEE EMBS Annual International Conference. New York City, USA, August, 2142-2145.
    • (2006) 28Th IEEE EMBS Annual International Conference. New York City , pp. 2142-2145
    • Popovic, M.R.1
  • 10
    • 31144449199 scopus 로고    scopus 로고
    • An electrode configuration technique using an electrode matrix arrangement for FES-based upper arm rehabilitation system
    • O’Dwyer S.B., O’Keeffe D.T., Coote S., and Lyons G.M. (2006) An electrode configuration technique using an electrode matrix arrangement for FES-based upper arm rehabilitation system. Med. Eng. Phys. 28-2:166-176.
    • (2006) Med. Eng. Phys , vol.28 , Issue.2 , pp. 166-176
    • O’Dwyer, S.B.1    O’Keeffe, D.T.2    Coote, S.3    Lyons, G.M.4
  • 12
    • 1842732200 scopus 로고    scopus 로고
    • Clinical evaluation of functional electrical therapy (FET) in chronic hemiplegic subjects
    • Popovic M.B., Popovic D.B., Schwirtlich L, and Sinkjaer T. (2004) Clinical evaluation of functional electrical therapy (FET) in chronic hemiplegic subjects. Neuromod, 7(2):133–140.
    • (2004) Neuromod , vol.7 , Issue.2 , pp. 133-140
    • Popovic, M.B.1    Popovic, D.B.2    Schwirtlich, L.3    Sinkjaer, T.4
  • 13
    • 85007097308 scopus 로고    scopus 로고
    • International Publication Number PCT WO 2005/075018A1
    • WIPO Patent, International Publication Number PCT WO 2005/075018A1