메뉴 건너뛰기




Volumn 6, Issue 8-84, 2016, Pages 54-59

Improving the efficiency of fuel combustion with regard to the uncertainty of measuring oxygen concentration

Author keywords

Excess air coefficient; Measurement uncertainty; Meteorological parameters; Monte Carlo method

Indexed keywords


EID: 85006990857     PISSN: 17293774     EISSN: 17294061     Source Type: Journal    
DOI: 10.15587/1729-4061.2016.85408     Document Type: Article
Times cited : (24)

References (15)
  • 1
    • 85006971248 scopus 로고    scopus 로고
    • Povyshenie jeffektivnosti szhiganija topliva v kotloagregatah
    • Volikov, A. N., Novikov, O. N., Okat'ev, A. N. (2010). Povyshenie jeffektivnosti szhiganija topliva v kotloagregatah. Jenergonadzor-inform, 1 (43), 54-57.
    • (2010) Jenergonadzor-inform , vol.1 , Issue.43 , pp. 54-57
    • Volikov, A.N.1    Novikov, O.N.2    Okat'ev, A.N.3
  • 2
    • 0037360826 scopus 로고    scopus 로고
    • Optimization of excess air for the improvement of environmental performance of a 150 MW boiler fired with Thai lignite
    • Kouprianov, V. I., Tanetsakunvatana, V. (2003). Optimization of excess air for the improvement of environmental performance of a 150 MW boiler fired with Thai lignite. Applied Energy, 74 (3-4), 445-453. doi: 10.1016/s0306-2619(02)00199-x
    • (2003) Applied Energy , vol.74 , Issue.3-4 , pp. 445-453
    • Kouprianov, V.I.1    Tanetsakunvatana, V.2
  • 3
    • 13344286021 scopus 로고    scopus 로고
    • Applications of a cost-based method of excess air optimization for the improvement of thermal efficiency and environmental performance of steam boilers
    • Kuprianov, V. I. (2005). Applications of a cost-based method of excess air optimization for the improvement of thermal efficiency and environmental performance of steam boilers. Renewable and Sustainable Energy Reviews, 9 (5), 474-498. doi: 10.1016/j.rser.2004.05.006
    • (2005) Renewable and Sustainable Energy Reviews , vol.9 , Issue.5 , pp. 474-498
    • Kuprianov, V.I.1
  • 4
    • 80054908165 scopus 로고    scopus 로고
    • Effect of excess air ratio and temperature on NOx emission from grate combustion of biomass in the staged air combustion scenario
    • Houshfar, E., Skreiberg, O., Lovas, T., Todorovic, D., Sorum, L. (2011). Effect of excess air ratio and temperature on NOx emission from grate combustion of biomass in the staged air combustion scenario. Energy & Fuels, 25 (10), 4643-4654. doi: 10.1021/ef200714d
    • (2011) Energy & Fuels , vol.25 , Issue.10 , pp. 4643-4654
    • Houshfar, E.1    Skreiberg, O.2    Lovas, T.3    Todorovic, D.4    Sorum, L.5
  • 5
    • 84947804490 scopus 로고    scopus 로고
    • Method for designing and calculating a boiler flue gas waste heat recovery system and its applications
    • Ning, F.-H., Wang, K., Zhang, H-Q., Cheng, K. (2015). Method for designing and calculating a boiler flue gas waste heat recovery system and its applications. Journal of Engineering for Thermal Energy and Power, 5, 745-749.
    • (2015) Journal of Engineering for Thermal Energy and Power , vol.5 , pp. 745-749
    • Ning, F.-H.1    Wang, K.2    Zhang, H.-Q.3    Cheng, K.4
  • 6
    • 84960845604 scopus 로고    scopus 로고
    • The development of energysaving operation technology of the biodiesel plant as a part of the cogeneration system
    • (79)
    • Chajkovs'ka, Je. Je. (2016). The development of energysaving operation technology of the biodiesel plant as a part of the cogeneration system. Eastern-European Journal of Enterprise Technologies, 1 (8 (79)), 4-10. doi: 10.15587/1729-4061.2016.59479
    • (2016) Eastern-European Journal of Enterprise Technologies , vol.1 , Issue.8 , pp. 4-10
    • Chajkovs'ka, J.J.1
  • 7
    • 84927728908 scopus 로고    scopus 로고
    • An energy saving control for combined cycle power plant by supervisory predictive scheme
    • Greece
    • Liu, X. J., Hou, G. L., Yin, C. (2007). An energy saving control for combined cycle power plant by supervisory predictive scheme. Proceedings of the European Control Conference. Greece, 2991-2998.
    • (2007) Proceedings of the European Control Conference , pp. 2991-2998
    • Liu, X.J.1    Hou, G.L.2    Yin, C.3
  • 8
    • 84979741912 scopus 로고    scopus 로고
    • Effect of the separated overfire air location on the combustion optimization and NOx reduction of a 600 MWe FW down-fired utility boiler with a novel combustion system
    • Ma, L., Fang, Q., Tan, P., Zhang, C., Chen, G., Lv, D. et al. (2016). Effect of the separated overfire air location on the combustion optimization and NOx reduction of a 600 MWe FW down-fired utility boiler with a novel combustion system. Applied Energy, 180, 104-115. doi: 10.1016/j.apenergy.2016.07.102
    • (2016) Applied Energy , vol.180 , pp. 104-115
    • Ma, L.1    Fang, Q.2    Tan, P.3    Zhang, C.4    Chen, G.5    Lv, D.6
  • 9
    • 84940642063 scopus 로고    scopus 로고
    • Exergy-based control strategy selection for flue gas recycle in oxy-fuel combustion plant
    • Luo, W., Wang, Q., Guo, J., Liu, Z., Zheng, C. (2015). Exergy-based control strategy selection for flue gas recycle in oxy-fuel combustion plant. Fuel, 161, 87-96. doi: 10.1016/j.fuel.2015.08.036
    • (2015) Fuel , vol.161 , pp. 87-96
    • Luo, W.1    Wang, Q.2    Guo, J.3    Liu, Z.4    Zheng, C.5
  • 10
    • 85006997445 scopus 로고    scopus 로고
    • Pidvyshhennja tochnosti vymirjuvannja koeficijenta nadlyshku povitrja v kotloagregatah iz zastosuvannjam gazoanalizatoriv elektrohimichnogo typu
    • Babak, V. P., Zaporozhets, A. O., Redko, O. O. (2015). Pidvyshhennja tochnosti vymirjuvannja koeficijenta nadlyshku povitrja v kotloagregatah iz zastosuvannjam gazoanalizatoriv elektrohimichnogo typu. Promyslova teplotehnika, 37 (1), 82-96.
    • (2015) Promyslova teplotehnika , vol.37 , Issue.1 , pp. 82-96
    • Babak, V.P.1    Zaporozhets, A.O.2    Redko, O.O.3
  • 11
    • 40949135768 scopus 로고    scopus 로고
    • Assessing the Influence of Meteorological Parameters on the Performance of Polyurethane Foam-Based Passive Air Samplers
    • Klanova, J., Eupr, P., Kohoutek, J., Harner, T. (2008). Assessing the Influence of Meteorological Parameters on the Performance of Polyurethane Foam-Based Passive Air Samplers. Environmental Science & Technology, 42 (2), 550-555. doi: 10.1021/es072098o
    • (2008) Environmental Science & Technology , vol.42 , Issue.2 , pp. 550-555
    • Klanova, J.1    Eupr, P.2    Kohoutek, J.3    Harner, T.4
  • 12
    • 0029667258 scopus 로고    scopus 로고
    • The relationship between synoptic, mesoscale and microscale meteorological parameters during poor air quality events in Athens, Greece
    • Katsoulis, B. D. (1996). The relationship between synoptic, mesoscale and microscale meteorological parameters during poor air quality events in Athens, Greece. Science of The Total Environment, 181 (1), 13-24. doi: 10.1016/0048-9697(95)04953-3
    • (1996) Science of The Total Environment , vol.181 , Issue.1 , pp. 13-24
    • Katsoulis, B.D.1
  • 15
    • 84898810609 scopus 로고    scopus 로고
    • Methodology of risk analysis by Monte Carlo Method applied to power generation with renewable energy
    • Pereira, E. J. da S., Pinho, J. T., Galhardo, M. A. B., Macedo, W. N. (2014). Methodology of risk analysis by Monte Carlo Method applied to power generation with renewable energy. Renewable Energy, 69, 347-355. doi: 10.1016/j.renene.2014.03.054
    • (2014) Renewable Energy , vol.69 , pp. 347-355
    • Pereira, E.J.S.1    Pinho, J.T.2    Galhardo, M.A.B.3    Macedo, W.N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.