메뉴 건너뛰기




Volumn 18, Issue 12, 2016, Pages 772-783

Glycemia, Treatment Satisfaction, Cognition, and Sleep Quality in Adults and Adolescents with Type 1 Diabetes When Using a Closed-Loop System Overnight Versus Sensor-Augmented Pump with Low-Glucose Suspend Function: A Randomized Crossover Study

(23)  Sharifi, Amin a   De Bock, Martin I b   Jayawardene, Dilshani a   Loh, Margaret M a   Horsburgh, Jodie C a   Berthold, Carolyn L b   Paramalingam, Nirubasini b   Bach, Leon A c   Colman, Peter G d   Davis, Elizabeth A b   Grosman, Benyamin e   Hendrieckx, Christel f,g   Jenkins, Alicia J a,h,i   Kumareswaran, Kavita c   Kurtz, Natalie e   Kyoong, Andrew a   MacIsaac, Richard J a,h   Speight, Jane f,g,j   Trawley, Steven f,g   Ward, Glenn M a,h   more..


Author keywords

Artificial pancreas; Closed loop; Continuous subcutaneous insulin infusion; Insulin pumps; Type 1 diabetes

Indexed keywords

GLUCOSE; INSULIN; ANTIDIABETIC AGENT; GLUCOSE BLOOD LEVEL;

EID: 85006983291     PISSN: 15209156     EISSN: 15578593     Source Type: Journal    
DOI: 10.1089/dia.2016.0288     Document Type: Article
Times cited : (78)

References (31)
  • 1
    • 84946427627 scopus 로고    scopus 로고
    • Home use of an artificial beta cell in type 1 diabetes
    • Thabit H, Tauschmann M, Allen JM, et al.: Home use of an artificial beta cell in type 1 diabetes. N Engl J Med 2015; 373:2129-2140.
    • (2015) N Engl J Med , vol.373 , pp. 2129-2140
    • Thabit, H.1    Tauschmann, M.2    Allen, J.M.3
  • 2
    • 84964720111 scopus 로고    scopus 로고
    • Variability of insulin requirements over 12 weeks of closed-loop insulin delivery in adults with type 1 diabetes
    • Ruan Y, Thabit H, Leelarathna L, et al.: Variability of insulin requirements over 12 weeks of closed-loop insulin delivery in adults with type 1 diabetes. Diabetes Care 2016; 39:830-832.
    • (2016) Diabetes Care , vol.39 , pp. 830-832
    • Ruan, Y.1    Thabit, H.2    Leelarathna, L.3
  • 3
    • 77249157244 scopus 로고    scopus 로고
    • Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: A phase 2 randomized crossover trial
    • Hovorka R, Allen JM, Elleri D, et al.: Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomized crossover trial. Lancet 2010; 375:743-751.
    • (2010) Lancet , vol.375 , pp. 743-751
    • Hovorka, R.1    Allen, J.M.2    Elleri, D.3
  • 4
    • 84992268896 scopus 로고    scopus 로고
    • Feasibility of outpatient fully integrated closed-loop control: First studies of wearable artificial pancreas
    • Kovatchev BP, Renard E, Cobelli C, et al.: Feasibility of outpatient fully integrated closed-loop control: first studies of wearable artificial pancreas. Diabetes Care 2013;36: 1851-1858.
    • (2013) Diabetes Care , vol.36 , pp. 1851-1858
    • Kovatchev, B.P.1    Renard, E.2    Cobelli, C.3
  • 5
    • 84904574791 scopus 로고    scopus 로고
    • Outpatient gly-cemic control with a bionic pancreas in type 1 diabetes
    • Russell SJ, El-Khatib FH, Sinha M, et al.: Outpatient gly-cemic control with a bionic pancreas in type 1 diabetes. N Engl J Med 2014;371:313-325.
    • (2014) N Engl J Med , vol.371 , pp. 313-325
    • Russell, S.J.1    El-Khatib, F.H.2    Sinha, M.3
  • 6
    • 84910135134 scopus 로고    scopus 로고
    • MD-logic overnight control for 6 weeks of home use in patients with type 1 diabetes: Randomized crossover trial
    • Nimri R, Muller I, Atlas E, et al.: MD-logic overnight control for 6 weeks of home use in patients with type 1 diabetes: randomized crossover trial. Diabetes Care 2014;37:3025-3032.
    • (2014) Diabetes Care , vol.37 , pp. 3025-3032
    • Nimri, R.1    Muller, I.2    Atlas, E.3
  • 7
    • 84908316913 scopus 로고    scopus 로고
    • Home use of closed-loop insulin delivery for overnight glucose control in adults with type 1 diabetes: A 4-week, multicentre, randomized crossover study
    • Thabit H, Lubina-Solomon A, Stadler M, et al.: Home use of closed-loop insulin delivery for overnight glucose control in adults with type 1 diabetes: a 4-week, multicentre, randomized crossover study. Lancet Diabetes Endocrinol 2014;2:701-709.
    • (2014) Lancet Diabetes Endocrinol , vol.2 , pp. 701-709
    • Thabit, H.1    Lubina-Solomon, A.2    Stadler, M.3
  • 8
    • 84903547471 scopus 로고    scopus 로고
    • Day and night home closed-loop insulin delivery in adults with type 1 diabetes: Three-center randomized crossover study
    • Leelarathna L, Dellweg S, Mader JK, et al.: Day and night home closed-loop insulin delivery in adults with type 1 diabetes: three-center randomized crossover study. Diabetes Care 2014;37:1931-1937.
    • (2014) Diabetes Care , vol.37 , pp. 1931-1937
    • Leelarathna, L.1    Dellweg, S.2    Mader, J.K.3
  • 9
    • 84899117172 scopus 로고    scopus 로고
    • Overnight closed-loop insulin delivery in young people with type 1 diabetes: A free-living, randomized clinical trial
    • Hovorka R, Elleri D, Thabit H, et al.: Overnight closed-loop insulin delivery in young people with type 1 diabetes: a free-living, randomized clinical trial. Diabetes Care 2014; 37:1204-1211.
    • (2014) Diabetes Care , vol.37 , pp. 1204-1211
    • Hovorka, R.1    Elleri, D.2    Thabit, H.3
  • 10
    • 84880274350 scopus 로고    scopus 로고
    • Threshold-based insulin-pump interruption for reduction of hypogly-cemia
    • Bergenstal RM, Klonoff DC, Garg SK, et al.: Threshold-based insulin-pump interruption for reduction of hypogly-cemia. N Engl J Med 2013;369:224-232.
    • (2013) N Engl J Med , vol.369 , pp. 224-232
    • Bergenstal, R.M.1    Klonoff, D.C.2    Garg, S.K.3
  • 11
    • 84884610823 scopus 로고    scopus 로고
    • Effect of sensor-augmented insulin pump therapy and automated insulin suspension vs standard insulin pump therapy on hypogly-cemia in patients with type 1 diabetes: A randomized clinical trial
    • Ly TT, Nicholas JA, Retterath A, et al.: Effect of sensor-augmented insulin pump therapy and automated insulin suspension vs standard insulin pump therapy on hypogly-cemia in patients with type 1 diabetes: a randomized clinical trial. JAMA 2013;310:1240-1247.
    • (2013) JAMA , vol.310 , pp. 1240-1247
    • Ly, T.T.1    Nicholas, J.A.2    Retterath, A.3
  • 12
    • 84948440168 scopus 로고    scopus 로고
    • Day and night closed-loop control using the integrated medtronic hybrid closed-loop system in type 1 diabetes at diabetes camp
    • Ly TT, Roy A, Grosman B, et al.: Day and night closed-loop control using the integrated medtronic hybrid closed-loop system in type 1 diabetes at diabetes camp. Diabetes Care 2015;38:1205-1211.
    • (2015) Diabetes Care , vol.38 , pp. 1205-1211
    • Ly, T.T.1    Roy, A.2    Grosman, B.3
  • 13
    • 84962367740 scopus 로고    scopus 로고
    • Feasibility of outpatient 24-hour closed-loop insulin delivery
    • De Bock MI, Roy A, Cooper MN, et al.: Feasibility of outpatient 24-hour closed-loop insulin delivery. Diabetes Care 2015;38:e186-e187.
    • (2015) Diabetes Care , vol.38 , pp. e186-e187
    • De Bock, M.I.1    Roy, A.2    Cooper, M.N.3
  • 14
    • 54849147700 scopus 로고    scopus 로고
    • Continuous glucose monitoring and intensive treatment of type i diabetes
    • The Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group. Continuous glucose monitoring and intensive treatment of type I diabetes. N Engl J Med 2008 359:1464-1476
    • (2008) N Engl J Med , vol.359 , pp. 1464-1476
  • 15
    • 77956080251 scopus 로고    scopus 로고
    • Evaluation of an algorithm to guide patients with type 1 diabetes treated with continuous subcutaneous insulin infusion on how to respond to real-time continuous glucose levels: A random-ized controlled trial
    • Jenkins AJ, Krishnamurthy B, Best JD, et al.: Evaluation of an algorithm to guide patients with type 1 diabetes treated with continuous subcutaneous insulin infusion on how to respond to real-time continuous glucose levels: a random-ized controlled trial. Diabetes Care 2010;33:1242-1248.
    • (2010) Diabetes Care , vol.33 , pp. 1242-1248
    • Jenkins, A.J.1    Krishnamurthy, B.2    Best, J.D.3
  • 16
    • 84923928162 scopus 로고    scopus 로고
    • Closing the loop overnight at home setting: Psychosocial impact for adolescents with type 1 diabetes and their parents
    • Barnard KD, Wysocki T, Allen JM, et al.: Closing the loop overnight at home setting: psychosocial impact for adolescents with type 1 diabetes and their parents. BMJ Open Diabetes Res Care 2014;2:e000025.
    • (2014) BMJ Open Diabetes Res Care , vol.2 , pp. e000025
    • Barnard, K.D.1    Wysocki, T.2    Allen, J.M.3
  • 17
    • 84355162122 scopus 로고    scopus 로고
    • Plasma 1, 5 anhydroglucitol levels, a measure of short-term glycae-mia: Assay assessment and lower levels in diabetic vs. Non-diabetic subjects
    • Januszewski AS, Karschimkus C, Davis KE, et al.: Plasma 1, 5 anhydroglucitol levels, a measure of short-term glycae-mia: assay assessment and lower levels in diabetic vs. non-diabetic subjects. Diabetes Res Clin Pract 2012;95:e17-e19.
    • (2012) Diabetes Res Clin Pract , vol.95 , pp. e17-e19
    • Januszewski, A.S.1    Karschimkus, C.2    Davis, K.E.3
  • 18
    • 0015371351 scopus 로고
    • A sensitive, precise radioimmunoassay of serum insulin relying on charcoal separation of bound and free hormone moieties
    • Albano JD, Ekins RP, Maritz G, Turner RC: A sensitive, precise radioimmunoassay of serum insulin relying on charcoal separation of bound and free hormone moieties. Acta Endocrinol (Copenh). 1972; 70:487-509.
    • (1972) Acta Endocrinol (Copenh). , vol.70 , pp. 487-509
    • Albano, J.D.1    Ekins, R.P.2    Maritz, G.3    Turner, R.C.4
  • 20
    • 0032972427 scopus 로고    scopus 로고
    • Diabetes treatment satisfaction questionnaire. Change version for use alongside status version provides appropriate solution where ceiling effects occur
    • Bradley C: Diabetes treatment satisfaction questionnaire. Change version for use alongside status version provides appropriate solution where ceiling effects occur. Diabetes Care 1999;22:530-532.
    • (1999) Diabetes Care , vol.22 , pp. 530-532
    • Bradley, C.1
  • 21
    • 0030922532 scopus 로고    scopus 로고
    • The problem areas in diabetes scale. An evaluation of its clinical utility
    • Welch GW, Jacobson AM, Polonsky WH. The problem areas in diabetes scale. An evaluation of its clinical utility. Diabetes Care 1997;20:760-766.
    • (1997) Diabetes Care , vol.20 , pp. 760-766
    • Welch, G.W.1    Jacobson, A.M.2    Polonsky, W.H.3
  • 22
    • 79956220310 scopus 로고    scopus 로고
    • Psychometric properties of the Hypoglycemia Fear Survey-II for adults with type 1 diabetes
    • Gonder-Frederick LA, Schmidt KM, Vajda KA, et al. Psychometric properties of the Hypoglycemia Fear Survey-II for adults with type 1 diabetes. Diabetes Care 2011;34:801-806.
    • (2011) Diabetes Care , vol.34 , pp. 801-806
    • Gonder-Frederick, L.A.1    Schmidt, K.M.2    Vajda, K.A.3
  • 23
    • 84868354226 scopus 로고    scopus 로고
    • Assessing fear of hypoglycemia in children with type 1 diabetes and their parents
    • Gonder-Frederick L, Nyer M, Shepard JA, et al.: Assessing fear of hypoglycemia in children with type 1 diabetes and their parents. Diabetes Manag (Lond) 2011;1:627-639.
    • (2011) Diabetes Manag (Lond) , vol.1 , pp. 627-639
    • Gonder-Frederick, L.1    Nyer, M.2    Shepard, J.A.3
  • 24
    • 0000435568 scopus 로고
    • Development and use of Stanford Sleepiness Scale (SSS)
    • Hoddes E, Zarcone V, Dement W: Development and use of Stanford Sleepiness Scale (SSS). Psychophysiology 1972; 9:150.
    • (1972) Psychophysiology , vol.9 , pp. 150
    • Hoddes, E.1    Zarcone, V.2    Dement, W.3
  • 25
    • 33746223031 scopus 로고    scopus 로고
    • Practice effects associated with the repeated assessment of cognitive function using the CogState battery at 10-minute, one week and one month test-retest intervals
    • Falleti MG, Maruff P, Collie A, et al.: Practice effects associated with the repeated assessment of cognitive function using the CogState battery at 10-minute, one week and one month test-retest intervals.JClin Exp Neuropsychol 2006;28: 1095-1112.
    • (2006) J Clin Exp Neuropsychol , vol.28 , pp. 1095-1112
    • Falleti, M.G.1    Maruff, P.2    Collie, A.3
  • 26
    • 0024389366 scopus 로고
    • The Pittsburgh Sleep Quality Index: A new instrument for psychiatric practice and research
    • Buysse DJ, Reynolds CF, 3rd, Monk TH, et al.: The Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research. Psychiatry Res 1989;28:193-213.
    • (1989) Psychiatry Res , vol.28 , pp. 193-213
    • Buysse, D.J.1    Reynolds, C.F.2    Monk, T.H.3
  • 27
    • 79953021776 scopus 로고    scopus 로고
    • Multinational study of subcutaneous model-predictive closed-loop control in type 1 diabetes mellitus: Summary of the results
    • Kovatchev B, Cobelli C, Renard E, et al.: Multinational study of subcutaneous model-predictive closed-loop control in type 1 diabetes mellitus: summary of the results. J Diabetes Sci Technol 2010;4:1374-1381.
    • (2010) J Diabetes Sci Technol , vol.4 , pp. 1374-1381
    • Kovatchev, B.1    Cobelli, C.2    Renard, E.3
  • 28
    • 84926287781 scopus 로고    scopus 로고
    • Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: An open-label randomized controlled crossover trial
    • Haidar A, Legault L, Messier V, et al.: Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomized controlled crossover trial. Lancet Diabetes En-docrinol 2015;3:17-26.
    • (2015) Lancet Diabetes En-docrinol , vol.3 , pp. 17-26
    • Haidar, A.1    Legault, L.2    Messier, V.3
  • 29
    • 84874368884 scopus 로고    scopus 로고
    • Nocturnal glucose control with an artificial pancreas at a diabetes camp
    • Phillip M, Battelino T, Atlas E, et al.: Nocturnal glucose control with an artificial pancreas at a diabetes camp. N Engl J Med 2013;368:824-833.
    • (2013) N Engl J Med , vol.368 , pp. 824-833
    • Phillip, M.1    Battelino, T.2    Atlas, E.3
  • 30
    • 84865453569 scopus 로고    scopus 로고
    • Fully integrated artificial pancreas in type 1 diabetes: Modular closed-loop glucose control maintains near normoglycemia
    • Breton M, Farret A, Bruttomesso D, et al.: Fully integrated artificial pancreas in type 1 diabetes: modular closed-loop glucose control maintains near normoglycemia. Diabetes 2012;61:2230-2237.
    • (2012) Diabetes , vol.61 , pp. 2230-2237
    • Breton, M.1    Farret, A.2    Bruttomesso, D.3
  • 31
    • 0023100526 scopus 로고
    • Puberty decreases insulin sensitivity
    • Bloch CA, Clemons P, Sperling MA: Puberty decreases insulin sensitivity. J Pediatr 1987;110:481-487.
    • (1987) J Pediatr , vol.110 , pp. 481-487
    • Bloch, C.A.1    Clemons, P.2    Ma, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.