메뉴 건너뛰기




Volumn 49, Issue 18, 2016, Pages 1351-1353

Direct bilirubin in clinical practice — Interpretation and haemolysis interference guidance reassessed

Author keywords

Direct bilirubin; Haemolysis; Hyperbilirubinaemia; Serum indices; Test interpretation

Indexed keywords

ALBUMIN; BILIRUBIN GLUCURONIDE; HEMOGLOBIN; TRIACYLGLYCEROL; VANADIC ACID; BILIRUBIN;

EID: 84999740162     PISSN: 00099120     EISSN: 18732933     Source Type: Journal    
DOI: 10.1016/j.clinbiochem.2016.09.005     Document Type: Article
Times cited : (13)

References (16)
  • 1
    • 84920261439 scopus 로고    scopus 로고
    • Clinical decision limits for interpretation of direct bilirubin — a CALIPER study of healthy multiethnic children and case report reviews
    • [1] Devgun, M.S., Chan, M.K., El-Nujumi, A.M., Abara, R., Armbruster, D., Adeli, K., Clinical decision limits for interpretation of direct bilirubin — a CALIPER study of healthy multiethnic children and case report reviews. Clin. Biochem. 48 (2015), 93–96.
    • (2015) Clin. Biochem. , vol.48 , pp. 93-96
    • Devgun, M.S.1    Chan, M.K.2    El-Nujumi, A.M.3    Abara, R.4    Armbruster, D.5    Adeli, K.6
  • 2
    • 84945457358 scopus 로고    scopus 로고
    • Systematic assessment of the hemolysis index: pros and cons
    • June
    • [2] Lippi, G., Systematic assessment of the hemolysis index: pros and cons. Adv. Clin. Chem., June 2015, 10.1016/bs.acc.2015.05.002.
    • (2015) Adv. Clin. Chem.
    • Lippi, G.1
  • 3
    • 42149136735 scopus 로고    scopus 로고
    • Bilirubin in clinical practice: a review
    • [3] Fevery, J., Bilirubin in clinical practice: a review. Liver Int., 2008, 592–605, 10.1111/j.1478-3231.2008.01716.x.
    • (2008) Liver Int. , pp. 592-605
    • Fevery, J.1
  • 4
    • 67650088580 scopus 로고    scopus 로고
    • Unbound (free) bilirubin: improving the paradigm for evaluating neonatal jaundice
    • [4] Ahlfors, C.E., Wennberg, R.P., Ostrow, J.D., Tiribelli, C., Unbound (free) bilirubin: improving the paradigm for evaluating neonatal jaundice. Clin. Chem. 55 (2009), 1288–1299.
    • (2009) Clin. Chem. , vol.55 , pp. 1288-1299
    • Ahlfors, C.E.1    Wennberg, R.P.2    Ostrow, J.D.3    Tiribelli, C.4
  • 5
    • 84999829199 scopus 로고    scopus 로고
    • Report no 215
    • (Accessed 19/01/2016)
    • [5] UKNEQAS, Report no 215. http://www.birminghamquality.org.uk (Accessed 19/01/2016).
    • UKNEQAS1
  • 7
    • 84999829224 scopus 로고    scopus 로고
    • Mannheim, Germany.. Accessed 19/01/
    • [7] Roche Diagnostics GmbH, Mannheim, Germany. www.roche.com. Accessed 19/01/2016.
    • (2016)
  • 9
    • 84999643091 scopus 로고    scopus 로고
    • Serum Index Gen.2, 010572179190c701v4.0, –02, cobas c, Roche Diagnostics, Gmbh, Mannheim, Germany.
    • [9] Serum Index Gen.2, 010572179190c701v4.0, 2014–02, cobas c, Roche Diagnostics, Gmbh, Mannheim, Germany.
    • (2014)
  • 10
    • 84999762398 scopus 로고    scopus 로고
    • Wako Chemicals, GmbH, Neuss, Germany.. Accessed19/01/
    • [10] Direct Bilirubin L-Type. Wako Chemicals, GmbH, Neuss, Germany. www.wako-chemicals.de. Accessed19/01/2016.
    • (2016)
  • 11
    • 0027960559 scopus 로고
    • Interference with clinical laboratory analyses
    • [11] Kroll, M.H., Elin, R.J., Interference with clinical laboratory analyses. Clin. Chem. 40 (1994), 1996–2005.
    • (1994) Clin. Chem. , vol.40 , pp. 1996-2005
    • Kroll, M.H.1    Elin, R.J.2
  • 12
    • 84901587186 scopus 로고    scopus 로고
    • Harmonization of automated hemolysis index assessment and use: is it possible?
    • [12] Dolci, A., Panteghini, M., Harmonization of automated hemolysis index assessment and use: is it possible?. Clin. Chim. Acta 432 (2014), 38–43.
    • (2014) Clin. Chim. Acta , vol.432 , pp. 38-43
    • Dolci, A.1    Panteghini, M.2
  • 13
    • 0024401592 scopus 로고
    • Delay in centrifugation and measurement of serum constituents in normal subjects
    • [13] Devgun, M.S., Delay in centrifugation and measurement of serum constituents in normal subjects. Clin. Physiol. Biochem. 7 (1989), 189–197.
    • (1989) Clin. Physiol. Biochem. , vol.7 , pp. 189-197
    • Devgun, M.S.1
  • 14
    • 79959295985 scopus 로고    scopus 로고
    • Evaluation of the interference of hemoglobin, bilirubin, and lipids on Roche Cobas 6000 assays
    • [14] Zhang Ji, J., Meng, Q.H., Evaluation of the interference of hemoglobin, bilirubin, and lipids on Roche Cobas 6000 assays. Clin. Chim. Acta 412 (2011), 1550–1553.
    • (2011) Clin. Chim. Acta , vol.412 , pp. 1550-1553
    • Zhang Ji, J.1    Meng, Q.H.2
  • 15
    • 84875165566 scopus 로고    scopus 로고
    • Advanced bilirubin measurement by a photometric method
    • [15] Penhaker, M., Kasik, V., Hrvolova, B., Advanced bilirubin measurement by a photometric method. Elektron. Elektrotech. 19 (2013), 47–50.
    • (2013) Elektron. Elektrotech. , vol.19 , pp. 47-50
    • Penhaker, M.1    Kasik, V.2    Hrvolova, B.3
  • 16
    • 84872484134 scopus 로고    scopus 로고
    • Novel mutations in the Dubin–Johnson syndrome gene ABCC2/MRP2 and associated biochemical changes
    • [16] Devgun, M.S., El-Nujumi, A.M., O'Dowd, G.J., Barbu, V., Poupon, R., Novel mutations in the Dubin–Johnson syndrome gene ABCC2/MRP2 and associated biochemical changes. Ann. Clin. Biochem. 49 (2012), 609–612.
    • (2012) Ann. Clin. Biochem. , vol.49 , pp. 609-612
    • Devgun, M.S.1    El-Nujumi, A.M.2    O'Dowd, G.J.3    Barbu, V.4    Poupon, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.