메뉴 건너뛰기




Volumn 27, Issue 12, 2016, Pages 1375-1380

Pulmonary Vein Isolation Using a Second-Generation Cryoballoon in Patients With Paroxysmal Atrial Fibrillation: One-Year Outcome Using a Single Big-Balloon 3-Minute Freeze Technique

Author keywords

atrial fibrillation; catheter ablation; cryoballoon; phrenic nerve paralysis; pulmonary vein isolation

Indexed keywords

ANTIARRHYTHMIC AGENT;

EID: 84992650909     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/jce.13078     Document Type: Article
Times cited : (45)

References (24)
  • 4
    • 84880628001 scopus 로고    scopus 로고
    • Improved in vivo performance of second-generation cryoballoon for pulmonary vein isolation
    • Coulombe N, Paulin J, Su W: Improved in vivo performance of second-generation cryoballoon for pulmonary vein isolation. J Cardiovasc Electrophysiol 2013;24:919-925.
    • (2013) J Cardiovasc Electrophysiol , vol.24 , pp. 919-925
    • Coulombe, N.1    Paulin, J.2    Su, W.3
  • 6
    • 84937523598 scopus 로고    scopus 로고
    • Best practice guide for cryoballoon ablation in atrial fibrillation: The compilation experience of more than 3000 procedures
    • Su W, Kowal R, Kowalski M, Metzner A, Svinarich JT, Wheelan K, Wang P: Best practice guide for cryoballoon ablation in atrial fibrillation: The compilation experience of more than 3000 procedures. Heart Rhythm 2015;12:1658-1666.
    • (2015) Heart Rhythm , vol.12 , pp. 1658-1666
    • Su, W.1    Kowal, R.2    Kowalski, M.3    Metzner, A.4    Svinarich, J.T.5    Wheelan, K.6    Wang, P.7
  • 8
    • 84939505914 scopus 로고    scopus 로고
    • Cryotherapy of cardiac arrhythmia: From basic science to the bedside
    • Avitall B, Kalinski A: Cryotherapy of cardiac arrhythmia: From basic science to the bedside. Heart Rhythm 2015;12:2195-2203.
    • (2015) Heart Rhythm , vol.12 , pp. 2195-2203
    • Avitall, B.1    Kalinski, A.2
  • 13
    • 84939803448 scopus 로고    scopus 로고
    • The impact of freezing time and balloon size on the thermodynamics and isolation efficacy during pulmonary vein isolation using the 2nd generation cryoballoon
    • Takami M, Lehmann HI, Misiri J, Parker KD, Sarmiento RI, Johnson SB, Packer DL: The impact of freezing time and balloon size on the thermodynamics and isolation efficacy during pulmonary vein isolation using the 2nd generation cryoballoon. Circ Arrhythm Electrophysiol 2015;8:836-845.
    • (2015) Circ Arrhythm Electrophysiol , vol.8 , pp. 836-845
    • Takami, M.1    Lehmann, H.I.2    Misiri, J.3    Parker, K.D.4    Sarmiento, R.I.5    Johnson, S.B.6    Packer, D.L.7
  • 21
    • 84944769220 scopus 로고    scopus 로고
    • Clinical significance of early recurrence after pulmonary vein antrum isolation in paroxysmal atrial fibrillation—Insight into the mechanism
    • Miyazaki S, Taniguchi H, Nakamura H, Takagi T, Iwasawa J, Hachiya H, Iesaka Y: Clinical significance of early recurrence after pulmonary vein antrum isolation in paroxysmal atrial fibrillation—Insight into the mechanism. Circ J 2015;79:2353-2359.
    • (2015) Circ J , vol.79 , pp. 2353-2359
    • Miyazaki, S.1    Taniguchi, H.2    Nakamura, H.3    Takagi, T.4    Iwasawa, J.5    Hachiya, H.6    Iesaka, Y.7
  • 22
    • 84955468717 scopus 로고    scopus 로고
    • Early recurrence after pulmonary vein isolation of paroxysmal atrial fibrillation with different ablation technologies—Prospective comparison of radiofrequency vs. second-generation cryoballoon ablation
    • Miyazaki S, Kuroi A, Hachiya H, Nakamura H, Taniguchi H, Ichihara N, Takagi T, Iwasawa J, Iesaka Y: Early recurrence after pulmonary vein isolation of paroxysmal atrial fibrillation with different ablation technologies—Prospective comparison of radiofrequency vs. second-generation cryoballoon ablation. Circ J 2016;80:346-353.
    • (2016) Circ J , vol.80 , pp. 346-353
    • Miyazaki, S.1    Kuroi, A.2    Hachiya, H.3    Nakamura, H.4    Taniguchi, H.5    Ichihara, N.6    Takagi, T.7    Iwasawa, J.8    Iesaka, Y.9
  • 23
    • 70350504285 scopus 로고    scopus 로고
    • Prevalence, predictors, and prognosis of atrial fibrillation early after pulmonary vein isolation: Findings from 3 months of continuous automatic ECG loop recordings
    • Joshi S, Choi AD, Kamath GS, Raiszadeh F, Marrero D, Badheka A, Mittal S, Steinberg JS: Prevalence, predictors, and prognosis of atrial fibrillation early after pulmonary vein isolation: Findings from 3 months of continuous automatic ECG loop recordings. J Cardiovasc Electrophysiol 2009;20:1089–1094.
    • (2009) J Cardiovasc Electrophysiol , vol.20 , pp. 1089-1094
    • Joshi, S.1    Choi, A.D.2    Kamath, G.S.3    Raiszadeh, F.4    Marrero, D.5    Badheka, A.6    Mittal, S.7    Steinberg, J.S.8
  • 24
    • 84898843152 scopus 로고    scopus 로고
    • Incidence and significance of early recurrences of atrial fibrillation after cryoballoon ablation: Insights from the multicenter Sustained Treatment of Paroxysmal Atrial Fibrillation (STOP AF) Trial
    • Andrade JG, Khairy P, Macle L, Packer DL, Lehmann JW, Holcomb RG, Ruskin JN, Dubuc M: Incidence and significance of early recurrences of atrial fibrillation after cryoballoon ablation: Insights from the multicenter Sustained Treatment of Paroxysmal Atrial Fibrillation (STOP AF) Trial. Circ Arrhythm Electrophysiol 2014;7:69-75.
    • (2014) Circ Arrhythm Electrophysiol , vol.7 , pp. 69-75
    • Andrade, J.G.1    Khairy, P.2    Macle, L.3    Packer, D.L.4    Lehmann, J.W.5    Holcomb, R.G.6    Ruskin, J.N.7    Dubuc, M.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.