-
1
-
-
84899643297
-
Results of the destination therapy post-food and drug administration approval study with a continuous flow left ventricular assist device: a prospective study using the INTERMACS registry (Interagency Registry for Mechanically Assisted Circulatory Support)
-
1 Jorde, U.P., Kushwaha, S.S., Tatooles, A.J., et al. Results of the destination therapy post-food and drug administration approval study with a continuous flow left ventricular assist device: a prospective study using the INTERMACS registry (Interagency Registry for Mechanically Assisted Circulatory Support). J Am Coll Cardiol 63 (2014), 1751–1757.
-
(2014)
J Am Coll Cardiol
, vol.63
, pp. 1751-1757
-
-
Jorde, U.P.1
Kushwaha, S.S.2
Tatooles, A.J.3
-
2
-
-
0035892018
-
Long-term use of a left ventricular assist device for end-stage heart failure
-
2 Rose, E.A., Gelijns, A.C., Moskowitz, A.J., et al. Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med 345 (2001), 1435–1443.
-
(2001)
N Engl J Med
, vol.345
, pp. 1435-1443
-
-
Rose, E.A.1
Gelijns, A.C.2
Moskowitz, A.J.3
-
3
-
-
73349129701
-
Advanced heart failure treated with continuous–flow left ventricular assist device
-
3 Slaughter, M.S., Rogers, J.G., Milano, C.A., et al. Advanced heart failure treated with continuous–flow left ventricular assist device. N Engl J Med 361 (2009), 2241–2251.
-
(2009)
N Engl J Med
, vol.361
, pp. 2241-2251
-
-
Slaughter, M.S.1
Rogers, J.G.2
Milano, C.A.3
-
4
-
-
84872849457
-
Fifth INTERMACS annual report: risk factor analysis from more than 6,000 mechanical circulatory support patients
-
4 Kirklin, J.K., Naftel, D.C., Kormos, R.L., et al. Fifth INTERMACS annual report: risk factor analysis from more than 6,000 mechanical circulatory support patients. J Heart Lung Transplant 32 (2013), 141–156.
-
(2013)
J Heart Lung Transplant
, vol.32
, pp. 141-156
-
-
Kirklin, J.K.1
Naftel, D.C.2
Kormos, R.L.3
-
5
-
-
84925722274
-
Clinical outcomes after continuous-flow left ventricular assist device: a systematic review
-
5 McIlvennan, C.K., Magid, K.H., Ambardekar, A.V., Thompson, J.S., Matlock, D.D., Allen, L.A., Clinical outcomes after continuous-flow left ventricular assist device: a systematic review. Circ Heart Fail 7 (2014), 1003–1013.
-
(2014)
Circ Heart Fail
, vol.7
, pp. 1003-1013
-
-
McIlvennan, C.K.1
Magid, K.H.2
Ambardekar, A.V.3
Thompson, J.S.4
Matlock, D.D.5
Allen, L.A.6
-
6
-
-
84930694859
-
Left ventricular assist devices: a rapidly evolving alternative to transplant
-
6 Mancini, D., Colombo, P.C., Left ventricular assist devices: a rapidly evolving alternative to transplant. J Am Coll Cardiol 65 (2015), 2542–2555.
-
(2015)
J Am Coll Cardiol
, vol.65
, pp. 2542-2555
-
-
Mancini, D.1
Colombo, P.C.2
-
7
-
-
34147100144
-
Ventricular arrhythmias during left ventricular assist device support
-
7 Bedi, M., Kormos, R., Winowich, S., McNamara, D.M., Mathier, M.A., Murali, S., Ventricular arrhythmias during left ventricular assist device support. Am J Cardiol 99 (2007), 1151–1153.
-
(2007)
Am J Cardiol
, vol.99
, pp. 1151-1153
-
-
Bedi, M.1
Kormos, R.2
Winowich, S.3
McNamara, D.M.4
Mathier, M.A.5
Murali, S.6
-
8
-
-
0036048966
-
Prolonged sustained ventricular fibrillation without loss of consciousness in patients supported by a left ventricular assist device
-
8 Fasseas, P., Kutalek, S.P., Kantharia, B.K., Prolonged sustained ventricular fibrillation without loss of consciousness in patients supported by a left ventricular assist device. Cardiology 97 (2002), 210–213.
-
(2002)
Cardiology
, vol.97
, pp. 210-213
-
-
Fasseas, P.1
Kutalek, S.P.2
Kantharia, B.K.3
-
9
-
-
0028035002
-
Malignant ventricular arrhythmias are well tolerated in patients receiving long-term left ventricular assist devices
-
9 Oz, M.C., Rose, E.A., Slater, J., Kuiper, J.J., Catanese, K.A., Levin, H.R., Malignant ventricular arrhythmias are well tolerated in patients receiving long-term left ventricular assist devices. J Am Coll Cardiol 24 (1994), 1688–1691.
-
(1994)
J Am Coll Cardiol
, vol.24
, pp. 1688-1691
-
-
Oz, M.C.1
Rose, E.A.2
Slater, J.3
Kuiper, J.J.4
Catanese, K.A.5
Levin, H.R.6
-
10
-
-
3543107249
-
Left ventricular assist device (LVAD) enables survival during 7 h of sustained ventricular fibrillation
-
10 Salzberg, S.P., Lachat, M.L., Zund, G., Turina, M.I., Left ventricular assist device (LVAD) enables survival during 7 h of sustained ventricular fibrillation. Eur J Cardiothorac Surg 26 (2004), 444–446.
-
(2004)
Eur J Cardiothorac Surg
, vol.26
, pp. 444-446
-
-
Salzberg, S.P.1
Lachat, M.L.2
Zund, G.3
Turina, M.I.4
-
11
-
-
84860835093
-
Twelve hours of sustained ventricular fibrillation supported by a continuous-flow left ventricular assist device
-
11 Sims, D.B., Rosner, G., Uriel, N., Gonzalez-Costello, J., Ehlert, F.A., Jorde, U.P., Twelve hours of sustained ventricular fibrillation supported by a continuous-flow left ventricular assist device. Pacing Clin Electrophysiol 35 (2012), e144–e148.
-
(2012)
Pacing Clin Electrophysiol
, vol.35
, pp. e144-e148
-
-
Sims, D.B.1
Rosner, G.2
Uriel, N.3
Gonzalez-Costello, J.4
Ehlert, F.A.5
Jorde, U.P.6
-
12
-
-
67649088100
-
Incidence of ventricular arrhythmias in patients on long-term support with a continuous-flow assist device (HeartMate II)
-
12 Andersen, M., Videbaek, R., Boesgaard, S., Sander, K., Hansen, P.B., Gustafsson, F., Incidence of ventricular arrhythmias in patients on long-term support with a continuous-flow assist device (HeartMate II). J Heart Lung Transplant 28 (2009), 733–735.
-
(2009)
J Heart Lung Transplant
, vol.28
, pp. 733-735
-
-
Andersen, M.1
Videbaek, R.2
Boesgaard, S.3
Sander, K.4
Hansen, P.B.5
Gustafsson, F.6
-
13
-
-
77949450625
-
Improved survival among ventricular assist device recipients with a concomitant implantable cardioverter-defibrillator
-
13 Cantillon, D.J., Tarakji, K.G., Kumbhani, D.J., Smedira, N.G., Starling, R.C., Wilkoff, B.L., Improved survival among ventricular assist device recipients with a concomitant implantable cardioverter-defibrillator. Heart Rhythm 7 (2010), 466–471.
-
(2010)
Heart Rhythm
, vol.7
, pp. 466-471
-
-
Cantillon, D.J.1
Tarakji, K.G.2
Kumbhani, D.J.3
Smedira, N.G.4
Starling, R.C.5
Wilkoff, B.L.6
-
14
-
-
84884512172
-
The role of implantable cardioverter-defibrillators in patients with continuous flow left ventricular assist devices
-
14 Enriquez, A.D., Calenda, B., Miller, M.A., Anyanwu, A.C., Pinney, S.P., The role of implantable cardioverter-defibrillators in patients with continuous flow left ventricular assist devices. Circ Arrhythm Electrophysiol 6 (2013), 668–674.
-
(2013)
Circ Arrhythm Electrophysiol
, vol.6
, pp. 668-674
-
-
Enriquez, A.D.1
Calenda, B.2
Miller, M.A.3
Anyanwu, A.C.4
Pinney, S.P.5
-
15
-
-
84879227526
-
Ventricular arrhythmias and implantable cardioverter-defibrillator therapy in patients with continuous-flow left ventricular assist devices: need for primary prevention?
-
15 Garan, A.R., Yuzefpolskaya, M., Colombo, P.C., et al. Ventricular arrhythmias and implantable cardioverter-defibrillator therapy in patients with continuous-flow left ventricular assist devices: need for primary prevention?. J Am Coll Cardiol 61 (2013), 2542–2550.
-
(2013)
J Am Coll Cardiol
, vol.61
, pp. 2542-2550
-
-
Garan, A.R.1
Yuzefpolskaya, M.2
Colombo, P.C.3
-
16
-
-
84938211767
-
Impact of implantable cardioverter defibrillators on survival of patients with centrifugal left ventricular assist devices
-
16 Lee, W., Tay, A., Subbiah, R.N., et al. Impact of implantable cardioverter defibrillators on survival of patients with centrifugal left ventricular assist devices. Pacing Clin Electrophysiol 38 (2015), 925–933.
-
(2015)
Pacing Clin Electrophysiol
, vol.38
, pp. 925-933
-
-
Lee, W.1
Tay, A.2
Subbiah, R.N.3
-
17
-
-
84856466614
-
Survival benefit of implantable cardioverter-defibrillators in left ventricular assist device-supported heart failure patients
-
17 Refaat, M.M., Tanaka, T., Kormos, R.L., et al. Survival benefit of implantable cardioverter-defibrillators in left ventricular assist device-supported heart failure patients. J Cardiac Fail 18 (2012), 140–145.
-
(2012)
J Cardiac Fail
, vol.18
, pp. 140-145
-
-
Refaat, M.M.1
Tanaka, T.2
Kormos, R.L.3
-
18
-
-
84903515434
-
Safety and efficacy of the MitraClip system for severe mitral regurgitation: a systematic review
-
18 Vakil, K., Roukoz, H., Sarraf, M., et al. Safety and efficacy of the MitraClip system for severe mitral regurgitation: a systematic review. Catheter Cardiovasc Interv 84 (2014), 129–136.
-
(2014)
Catheter Cardiovasc Interv
, vol.84
, pp. 129-136
-
-
Vakil, K.1
Roukoz, H.2
Sarraf, M.3
-
19
-
-
68049122102
-
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement
-
19 Moher, D., Liberati, A., Tetzlaff, J., Altman, D.G., Group, P., Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS, 6, 2009, e1000097.
-
(2009)
PLoS
, vol.6
, pp. e1000097
-
-
Moher, D.1
Liberati, A.2
Tetzlaff, J.3
Altman, D.G.4
Group, P.5
-
20
-
-
84860389488
-
Cardiac resynchronization therapy in patients with minimal heart failure: a systematic review and meta-analysis
-
20 Adabag, S., Roukoz, H., Anand, I.S., Moss, A.J., Cardiac resynchronization therapy in patients with minimal heart failure: a systematic review and meta-analysis. J Am Coll Cardiol 58 (2011), 935–941.
-
(2011)
J Am Coll Cardiol
, vol.58
, pp. 935-941
-
-
Adabag, S.1
Roukoz, H.2
Anand, I.S.3
Moss, A.J.4
-
21
-
-
0031754739
-
The feasibility of creating a checklist for the assessment of the methodological quality both of randomised and non-randomised studies of health care interventions
-
21 Downs, S.H., Black, N., The feasibility of creating a checklist for the assessment of the methodological quality both of randomised and non-randomised studies of health care interventions. Journal of epidemiology and community health 52 (1998), 377–384.
-
(1998)
Journal of epidemiology and community health
, vol.52
, pp. 377-384
-
-
Downs, S.H.1
Black, N.2
-
22
-
-
84880048931
-
Helicopter emergency medical services for adults with major trauma
-
22 Galvagno, S.M. Jr., Thomas, S., Stephens, C., et al. Helicopter emergency medical services for adults with major trauma. Cochrane Database Syst Rev, 3, 2013, CD009228.
-
(2013)
Cochrane Database Syst Rev
, vol.3
, pp. CD009228
-
-
Galvagno, S.M.1
Thomas, S.2
Stephens, C.3
-
24
-
-
84872848201
-
The 2013 International Society for Heart and Lung Transplantation guidelines for mechanical circulatory support: executive summary
-
24 Feldman, D., Pamboukian, S.V., Teuteberg, J.J., et al. The 2013 International Society for Heart and Lung Transplantation guidelines for mechanical circulatory support: executive summary. J Heart Lung Transplant 32 (2013), 157–187.
-
(2013)
J Heart Lung Transplant
, vol.32
, pp. 157-187
-
-
Feldman, D.1
Pamboukian, S.V.2
Teuteberg, J.J.3
-
25
-
-
84883019483
-
Ventricular arrhythmias after left ventricular assist device
-
25 Nakahara, S., Chien, C., Gelow, J., et al. Ventricular arrhythmias after left ventricular assist device. Circ Arrhythm Electrophysiol 6 (2013), 648–654.
-
(2013)
Circ Arrhythm Electrophysiol
, vol.6
, pp. 648-654
-
-
Nakahara, S.1
Chien, C.2
Gelow, J.3
-
26
-
-
34548311569
-
Use of a continuous-flow device in patients awaiting heart transplantation
-
26 Miller, L.W., Pagani, F.D., Russell, S.D., et al. Use of a continuous-flow device in patients awaiting heart transplantation. N Engl J Med 357 (2007), 885–896.
-
(2007)
N Engl J Med
, vol.357
, pp. 885-896
-
-
Miller, L.W.1
Pagani, F.D.2
Russell, S.D.3
-
27
-
-
18144400630
-
Effects of left ventricular assist device therapy on ventricular arrhythmias
-
27 Ziv, O., Dizon, J., Thosani, A., Naka, Y., Magnano, A.R., Garan, H., Effects of left ventricular assist device therapy on ventricular arrhythmias. J Am Coll Cardiol 45 (2005), 1428–1434.
-
(2005)
J Am Coll Cardiol
, vol.45
, pp. 1428-1434
-
-
Ziv, O.1
Dizon, J.2
Thosani, A.3
Naka, Y.4
Magnano, A.R.5
Garan, H.6
-
28
-
-
84860834237
-
Risk of mortality for ventricular arrhythmia in ambulatory LVAD patients
-
28 Brenyo, A., Rao, M., Koneru, S., et al. Risk of mortality for ventricular arrhythmia in ambulatory LVAD patients. J Cardiovasc Electrophysiol 23 (2012), 515–520.
-
(2012)
J Cardiovasc Electrophysiol
, vol.23
, pp. 515-520
-
-
Brenyo, A.1
Rao, M.2
Koneru, S.3
|