메뉴 건너뛰기




Volumn 35, Issue , 2016, Pages 278-280

Soft palate trauma induced during GlideScope intubation

Author keywords

Airway management issues; Induction of anesthesia; Quality improvement; Tracheal intubation; Trauma in anesthesia

Indexed keywords

FENTANYL; LIDOCAINE; PROPOFOL; ROCURONIUM;

EID: 84991458128     PISSN: 09528180     EISSN: 18734529     Source Type: Journal    
DOI: 10.1016/j.jclinane.2016.08.011     Document Type: Article
Times cited : (8)

References (7)
  • 1
    • 0042424630 scopus 로고    scopus 로고
    • Use of a new videolaryngoscope (GlideScope®) in the management of a difficult airway
    • [1] Cooper, R.M., Use of a new videolaryngoscope (GlideScope®) in the management of a difficult airway. Can J Anesth 50 (2003), 611–613.
    • (2003) Can J Anesth , vol.50 , pp. 611-613
    • Cooper, R.M.1
  • 2
    • 78650708929 scopus 로고    scopus 로고
    • Routine clinical practice effectiveness of the GlideScope® in difficult airway management: an analysis of 2,004 GlideScope® intubations, complications, and failures from two institutions
    • [2] Aziz, M.F., Healy, D., Kheterpal, S., Fu, R.F., et al. Routine clinical practice effectiveness of the GlideScope® in difficult airway management: an analysis of 2,004 GlideScope® intubations, complications, and failures from two institutions. Anesthesiology 114:1 (2011), 34–41.
    • (2011) Anesthesiology , vol.114 , Issue.1 , pp. 34-41
    • Aziz, M.F.1    Healy, D.2    Kheterpal, S.3    Fu, R.F.4
  • 3
    • 33846605602 scopus 로고    scopus 로고
    • Complications associated with the use of the GSVL
    • [3] Cooper, R.M., Complications associated with the use of the GSVL. Can J Anaesth 54:1 (2007), 54–57.
    • (2007) Can J Anaesth , vol.54 , Issue.1 , pp. 54-57
    • Cooper, R.M.1
  • 4
    • 84991449180 scopus 로고    scopus 로고
    • Difficult airway simulation for novice physicians: a randomized trial comparing traditional and video-assisted laryngoscopy
    • [P150-P150]
    • [4] Ambrosio, A.A., Pfannenstiel, T.J., Bach, K.K., Cornelissen, C., Gaconnet, C., Brigger, M.T., Difficult airway simulation for novice physicians: a randomized trial comparing traditional and video-assisted laryngoscopy. Otolaryngol Head Neck Surg, 149(2 Suppl.), 2013 [P150-P150].
    • (2013) Otolaryngol Head Neck Surg , vol.149 , Issue.2
    • Ambrosio, A.A.1    Pfannenstiel, T.J.2    Bach, K.K.3    Cornelissen, C.4    Gaconnet, C.5    Brigger, M.T.6
  • 5
    • 36749093518 scopus 로고    scopus 로고
    • The GlideScope-specific rigid stylet and standard malleable stylet are equally effective for GlideScope use
    • [5] Turkstra, T.P., Harle, C.C., Armstrong, K.P., Armstrong, P.M., et al. The GlideScope-specific rigid stylet and standard malleable stylet are equally effective for GlideScope use. Can J Anaesth 54:11 (2007), 891–896.
    • (2007) Can J Anaesth , vol.54 , Issue.11 , pp. 891-896
    • Turkstra, T.P.1    Harle, C.C.2    Armstrong, K.P.3    Armstrong, P.M.4
  • 6
    • 73949127956 scopus 로고    scopus 로고
    • The Flex-It™ stylet is less effective than a malleable stylet for orotracheal intubation using the GlideScope®
    • [6] Turkstra, T.P., Jones, P.M., Ower, K.M., Gros, M.L., The Flex-It™ stylet is less effective than a malleable stylet for orotracheal intubation using the GlideScope®. Anesth Analg 109:6 (2009), 1856–1859.
    • (2009) Anesth Analg , vol.109 , Issue.6 , pp. 1856-1859
    • Turkstra, T.P.1    Jones, P.M.2    Ower, K.M.3    Gros, M.L.4
  • 7
    • 33846644972 scopus 로고    scopus 로고
    • Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope
    • [7] Jones, P.M., Turkstra, T.P., Armstrong, K.P., Armstrong, P.M., et al. Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope. Can J Anaesth 54:1 (2007), 21–27.
    • (2007) Can J Anaesth , vol.54 , Issue.1 , pp. 21-27
    • Jones, P.M.1    Turkstra, T.P.2    Armstrong, K.P.3    Armstrong, P.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.