메뉴 건너뛰기




Volumn 53, Issue 6, 2016, Pages 715-716

Glucose sampling: importance of citrate

Author keywords

[No Author keywords available]

Indexed keywords

CITRIC ACID; GLUCOSE; ANTICOAGULANT AGENT; GLUCOSE BLOOD LEVEL; HEPARIN; SODIUM FLUORIDE;

EID: 84991206660     PISSN: 00045632     EISSN: 17581001     Source Type: Journal    
DOI: 10.1177/0004563216645621     Document Type: Editorial
Times cited : (7)

References (5)
  • 1
    • 84926338262 scopus 로고    scopus 로고
    • Classification and diagnosis of diabetes
    • American Diabetes Association. Classification and diagnosis of diabetes. Diabetes Care 2015; 38: S8–S16.
    • (2015) Diabetes Care , vol.38 , pp. S8-S16
  • 2
    • 79957759364 scopus 로고    scopus 로고
    • Executive summary: guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus
    • Sacks DB, Arnold M, Bakris GL. Executive summary: guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem 2011; 57: 793–798.
    • (2011) Clin Chem , vol.57 , pp. 793-798
    • Sacks, D.B.1    Arnold, M.2    Bakris, G.L.3
  • 3
    • 84924755738 scopus 로고    scopus 로고
    • What is the most suitable blood collection tube for glucose estimation?
    • Dimeski G, Yow KS, Brown NN. What is the most suitable blood collection tube for glucose estimation? Ann Clin Biochem 2015; 52: 270–275.
    • (2015) Ann Clin Biochem , vol.52 , pp. 270-275
    • Dimeski, G.1    Yow, K.S.2    Brown, N.N.3
  • 4
    • 65949094591 scopus 로고    scopus 로고
    • Acidification of blood is superior to sodium fluoride as an inhibitor of glycolysis
    • Gambino R, Piscitelli J, Ackattupathil TA. Acidification of blood is superior to sodium fluoride as an inhibitor of glycolysis. Clin Chem 2009; 55: 1019–1021.
    • (2009) Clin Chem , vol.55 , pp. 1019-1021
    • Gambino, R.1    Piscitelli, J.2    Ackattupathil, T.A.3
  • 5
    • 84872038947 scopus 로고    scopus 로고
    • It's time for a better blood collection tube to improve the reliability of glucose results
    • Peake MJ, Bruns DE, Sacks DB. It's time for a better blood collection tube to improve the reliability of glucose results. Diabetes Care 2013; 36: e2–e2.
    • (2013) Diabetes Care , vol.36 , pp. e2
    • Peake, M.J.1    Bruns, D.E.2    Sacks, D.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.