메뉴 건너뛰기




Volumn 91, Issue 3, 2016, Pages 529-539

Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANIMAL EXPERIMENT; ARTICLE; ARTIFACT; ELECTROMYOGRAPHY; ELECTRONEUROGRAPHY; GASTROCNEMIUS MUSCLE; IN VIVO STUDY; INTEGRATED CIRCUIT; NEURAL DUST; NEUROLOGICAL IMPLANT; NONHUMAN; PERIPHERAL NERVOUS SYSTEM; PRIORITY JOURNAL; RAT; SCIATIC NERVE; SENSOR; SIGNAL PROCESSING; TEMPERATURE; ULTRASOUND; WIRELESS COMMUNICATION; ANIMAL; DEVICES; ELECTROPHYSIOLOGY; PHYSIOLOGY; PROCEDURES; PROSTHESES AND ORTHOSES; REMOTE SENSING;

EID: 84991109329     PISSN: 08966273     EISSN: 10974199     Source Type: Journal    
DOI: 10.1016/j.neuron.2016.06.034     Document Type: Article
Times cited : (423)

References (39)
  • 2
    • 28544444354 scopus 로고    scopus 로고
    • High-frequency electrical conduction block of mammalian peripheral motor nerve
    • Bhadra, N., Kilgore, K.L., High-frequency electrical conduction block of mammalian peripheral motor nerve. Muscle Nerve 32 (2005), 782–790.
    • (2005) Muscle Nerve , vol.32 , pp. 782-790
    • Bhadra, N.1    Kilgore, K.L.2
  • 4
    • 85027927027 scopus 로고    scopus 로고
    • A 4.78 mm2 fully-integrated neuromodulation SoC combining 64 acquisition channels with digital compression and simultaneous dual stimulation
    • Biederman, W., Yeager, D.J., Narevsky, N., Leverett, L., Neely, R., Carmena, J.M., Alon, E., Rabaey, J.M., A 4.78 mm2 fully-integrated neuromodulation SoC combining 64 acquisition channels with digital compression and simultaneous dual stimulation. IEEE J. Solid State Circuits 50 (2015), 1038–1047.
    • (2015) IEEE J. Solid State Circuits , vol.50 , pp. 1038-1047
    • Biederman, W.1    Yeager, D.J.2    Narevsky, N.3    Leverett, L.4    Neely, R.5    Carmena, J.M.6    Alon, E.7    Rabaey, J.M.8
  • 7
    • 85027950263 scopus 로고    scopus 로고
    • A mm-sized implantal medical device (IMD) with ultrasonic power transfer and a hybrid bi-directional data link
    • Charthad, J., Weber, M.J., Chang, T.C., Arbabian, A., A mm-sized implantal medical device (IMD) with ultrasonic power transfer and a hybrid bi-directional data link. IEEE J. Solid State Circuits 50 (2015), 1741–1753.
    • (2015) IEEE J. Solid State Circuits , vol.50 , pp. 1741-1753
    • Charthad, J.1    Weber, M.J.2    Chang, T.C.3    Arbabian, A.4
  • 8
    • 0034766340 scopus 로고    scopus 로고
    • An implantable neuroprosthesis for restoring bladder and bowel control to patients with spinal cord injuries: a multicenter trial
    • Creasey, G.H., Grill, J.H., Korsten, M., U, H.S., Betz, R., Anderson, R., Walter, J., Implanted Neuroprosthesis Research Group. An implantable neuroprosthesis for restoring bladder and bowel control to patients with spinal cord injuries: a multicenter trial. Arch. Phys. Med. Rehabil. 82 (2001), 1512–1519.
    • (2001) Arch. Phys. Med. Rehabil. , vol.82 , pp. 1512-1519
    • Creasey, G.H.1    Grill, J.H.2    Korsten, M.3    Betz, R.4    Anderson, R.5    Walter, J.6
  • 9
    • 84862850321 scopus 로고    scopus 로고
    • Concurrent recordings of bladder afferents from multiple nerves using a microfabricated PDMS microchannel electrode array
    • Delivopoulos, E., Chew, D.J., Minev, I.R., Fawcett, J.W., Lacour, S.P., Concurrent recordings of bladder afferents from multiple nerves using a microfabricated PDMS microchannel electrode array. Lab Chip 12 (2012), 2540–2551.
    • (2012) Lab Chip , vol.12 , pp. 2540-2551
    • Delivopoulos, E.1    Chew, D.J.2    Minev, I.R.3    Fawcett, J.W.4    Lacour, S.P.5
  • 10
    • 51949105156 scopus 로고    scopus 로고
    • A 2uW 100 nV/rtHz chopper-stabilized instrumentation amplifier for chronic measurement of neural field potentials
    • Denison, T., Consoer, K., Santa, W., Avestruz, A.T., Cooley, J., Kelly, A., A 2uW 100 nV/rtHz chopper-stabilized instrumentation amplifier for chronic measurement of neural field potentials. IEEE J. Solid State Circuits 42 (2007), 2934–2945.
    • (2007) IEEE J. Solid State Circuits , vol.42 , pp. 2934-2945
    • Denison, T.1    Consoer, K.2    Santa, W.3    Avestruz, A.T.4    Cooley, J.5    Kelly, A.6
  • 11
    • 84876227647 scopus 로고    scopus 로고
    • Drug discovery: a jump-start for electroceuticals
    • Famm, K., Litt, B., Tracey, K.J., Boyden, E.S., Slaoui, M., Drug discovery: a jump-start for electroceuticals. Nature 496 (2013), 159–161.
    • (2013) Nature , vol.496 , pp. 159-161
    • Famm, K.1    Litt, B.2    Tracey, K.J.3    Boyden, E.S.4    Slaoui, M.5
  • 12
    • 84991044150 scopus 로고    scopus 로고
    • Information for manufacturers seeking market clearance of diagnostic ultrasound systems and transducers.
    • Food and Drug Administration (2008). Information for manufacturers seeking market clearance of diagnostic ultrasound systems and transducers. http://www.fda.gov/downloads/UCM070911.pdf.
    • (2008)
  • 14
    • 0024634621 scopus 로고
    • Nonlinear muscle recruitment during intramuscular and nerve stimulation
    • Gruner, J.A., Mason, C.P., Nonlinear muscle recruitment during intramuscular and nerve stimulation. J. Rehabil. Res. Dev. 26 (1989), 1–16.
    • (1989) J. Rehabil. Res. Dev. , vol.26 , pp. 1-16
    • Gruner, J.A.1    Mason, C.P.2
  • 15
    • 84991061771 scopus 로고    scopus 로고
    • IEEE standards for safety levels with respect to human exposure to radio frequency electromagnetic fields, 3 khz to 300 ghz.
    • International Committee on Electromagnetic Safety (2006). IEEE standards for safety levels with respect to human exposure to radio frequency electromagnetic fields, 3 khz to 300 ghz. http://emfguide.itu.int/pdfs/C95.1-2005.pdf.
    • (2006)
  • 17
    • 84959366202 scopus 로고    scopus 로고
    • A wireless fully passive neural recording device for unobtrusive neuropotential monitoring
    • Kiourti, A., Lee, C.W.L., Chae, J., Volakis, J.L., A wireless fully passive neural recording device for unobtrusive neuropotential monitoring. IEEE Trans. Biomed. Eng. 63 (2016), 131–137.
    • (2016) IEEE Trans. Biomed. Eng. , vol.63 , pp. 131-137
    • Kiourti, A.1    Lee, C.W.L.2    Chae, J.3    Volakis, J.L.4
  • 18
  • 20
    • 79960346562 scopus 로고    scopus 로고
    • Miniature ultrasonically powered wireless nerve cuff stimulator
    • Larson, P.J., Towe, B.C., Miniature ultrasonically powered wireless nerve cuff stimulator. Proc. IEEE Eng. Med. Biol. Soc. 2011 (2011), 265–268.
    • (2011) Proc. IEEE Eng. Med. Biol. Soc. , vol.2011 , pp. 265-268
    • Larson, P.J.1    Towe, B.C.2
  • 21
    • 84879952295 scopus 로고    scopus 로고
    • A wideband dual-antenna receiver for wireless recording from animals behaving in large arenas
    • Lee, S.B., Yin, M., Manns, J.R., Ghovanloo, M., A wideband dual-antenna receiver for wireless recording from animals behaving in large arenas. IEEE Trans. Biomed. Eng. 60 (2013), 1993–2004.
    • (2013) IEEE Trans. Biomed. Eng. , vol.60 , pp. 1993-2004
    • Lee, S.B.1    Yin, M.2    Manns, J.R.3    Ghovanloo, M.4
  • 23
    • 84953431734 scopus 로고    scopus 로고
    • High-density surface electromyography provides reliable estimates of motor unit behaviour
    • Martinez-Valdes, E., Laine, C.M., Falla, D., Mayer, F., Farina, D., High-density surface electromyography provides reliable estimates of motor unit behaviour. Clin. Neurophysiol. 127 (2016), 2534–2541.
    • (2016) Clin. Neurophysiol. , vol.127 , pp. 2534-2541
    • Martinez-Valdes, E.1    Laine, C.M.2    Falla, D.3    Mayer, F.4    Farina, D.5
  • 24
    • 84886526256 scopus 로고    scopus 로고
    • An electroacoustic recording device for wireless sensing of neural signals
    • Meng, H., Sahin, M., An electroacoustic recording device for wireless sensing of neural signals. Proc. IEEE Eng. Med. Biol. Soc., 2013, 3086–3088.
    • (2013) Proc. IEEE Eng. Med. Biol. Soc. , pp. 3086-3088
    • Meng, H.1    Sahin, M.2
  • 27
    • 77949487799 scopus 로고    scopus 로고
    • Ultrasonic transcutaneous energy transfer for powering implanted devices
    • Ozeri, S., Shmilovitz, D., Ultrasonic transcutaneous energy transfer for powering implanted devices. Ultrasonics 50 (2010), 556–566.
    • (2010) Ultrasonics , vol.50 , pp. 556-566
    • Ozeri, S.1    Shmilovitz, D.2
  • 28
    • 84870038215 scopus 로고    scopus 로고
    • The vagus nerve and the inflammatory reflex–linking immunity and metabolism
    • Pavlov, V.A., Tracey, K.J., The vagus nerve and the inflammatory reflex–linking immunity and metabolism. Nat. Rev. Endocrinol. 8 (2012), 743–754.
    • (2012) Nat. Rev. Endocrinol. , vol.8 , pp. 743-754
    • Pavlov, V.A.1    Tracey, K.J.2
  • 32
    • 80053571396 scopus 로고    scopus 로고
    • A fully passive wireless microsystem for recording of neuropotential using RF backscattering methods
    • Schwerdt, H.N., Xu, W., Shekhar, S., Abbaspour-Tamijani, A., Towe, B.C., Miranda, F.A., Chae, J., A fully passive wireless microsystem for recording of neuropotential using RF backscattering methods. IEEE JMEMS 20 (2011), 1119–1130.
    • (2011) IEEE JMEMS , vol.20 , pp. 1119-1130
    • Schwerdt, H.N.1    Xu, W.2    Shekhar, S.3    Abbaspour-Tamijani, A.4    Towe, B.C.5    Miranda, F.A.6    Chae, J.7
  • 33
    • 84886289534 scopus 로고    scopus 로고
    • Neural dust: an ultrasonic, low power solution for chronic brain-machine interface
    • Published online July 8, 2013. arXiv:1307:2196.
    • Seo, D., Carmena, J.M., Rabaey, J.M., Alon, E., and Maharbiz, M.M. (2013). Neural dust: an ultrasonic, low power solution for chronic brain-machine interface. Published online July 8, 2013. arXiv:1307:2196. http://arxiv.org/abs/1307.2196.
    • (2013)
    • Seo, D.1    Carmena, J.M.2    Rabaey, J.M.3    Alon, E.4    Maharbiz, M.M.5
  • 34
    • 84926195286 scopus 로고    scopus 로고
    • Model validation of untethered, ultrasonic neural dust motes for cortical recording
    • Seo, D., Carmena, J.M., Rabaey, J.M., Maharbiz, M.M., Alon, E., Model validation of untethered, ultrasonic neural dust motes for cortical recording. J. Neurosci. Methods 244 (2014), 114–122.
    • (2014) J. Neurosci. Methods , vol.244 , pp. 114-122
    • Seo, D.1    Carmena, J.M.2    Rabaey, J.M.3    Maharbiz, M.M.4    Alon, E.5
  • 39
    • 84926363156 scopus 로고    scopus 로고
    • Wireless neurosensor for full-spectrum electrophysiology recordings during free behavior
    • Yin, M., Borton, D.A., Komar, J., Agha, N., Lu, Y., Li, H., Laurens, J., Lang, Y., Li, Q., Bull, C., et al. Wireless neurosensor for full-spectrum electrophysiology recordings during free behavior. Neuron 84 (2014), 1170–1182.
    • (2014) Neuron , vol.84 , pp. 1170-1182
    • Yin, M.1    Borton, D.A.2    Komar, J.3    Agha, N.4    Lu, Y.5    Li, H.6    Laurens, J.7    Lang, Y.8    Li, Q.9    Bull, C.10