메뉴 건너뛰기




Volumn 9, Issue 7, 2016, Pages 769-782

Transthoracic 3D Echocardiographic Left Heart Chamber Quantification Using an Automated Adaptive Analytics Algorithm

Author keywords

3 dimensional echocardiography; automation; cardiac chamber quantification

Indexed keywords

ADULT; ALGORITHM; ARTICLE; AUTOMATION; CARDIOVASCULAR MAGNETIC RESONANCE; CONTROLLED STUDY; ECHOCARDIOGRAPH; FEASIBILITY STUDY; FEMALE; HEART LEFT ATRIUM; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART LEFT VENTRICLE ENDSYSTOLIC VOLUME; HEART LEFT VENTRICLE VOLUME; HEART VOLUME; HUMAN; IMAGING SOFTWARE; LEFT ATRIAL VOLUME; MAJOR CLINICAL STUDY; MALE; MEASUREMENT ACCURACY; PRIORITY JOURNAL; REPRODUCIBILITY; TEST RETEST RELIABILITY; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY; AGED; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; DIAGNOSTIC IMAGING; HEART ATRIUM; HEART ATRIUM FUNCTION; HEART LEFT VENTRICLE FUNCTION; HEART MUSCLE ISCHEMIA; HEART STROKE VOLUME; HEART VENTRICLE; MIDDLE AGED; NUCLEAR MAGNETIC RESONANCE IMAGING; OBSERVER VARIATION; PATHOPHYSIOLOGY; PREDICTIVE VALUE; PROCEDURES; VALIDATION STUDY; WORKFLOW;

EID: 84990946954     PISSN: 1936878X     EISSN: 18767591     Source Type: Journal    
DOI: 10.1016/j.jcmg.2015.12.020     Document Type: Article
Times cited : (182)

References (16)
  • 1
    • 47349116645 scopus 로고    scopus 로고
    • Real-time 3-dimensional echocardiographic quantification of left ventricular volumes: multicenter study for validation with magnetic resonance imaging and investigation of sources of error
    • 1 Mor-Avi, V., Jenkins, C., Kuhl, H.P., et al. Real-time 3-dimensional echocardiographic quantification of left ventricular volumes: multicenter study for validation with magnetic resonance imaging and investigation of sources of error. J Am Coll Cardiol Img 1 (2008), 413–423.
    • (2008) J Am Coll Cardiol Img , vol.1 , pp. 413-423
    • Mor-Avi, V.1    Jenkins, C.2    Kuhl, H.P.3
  • 2
    • 33747431187 scopus 로고    scopus 로고
    • Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference
    • 2 Sugeng, L., Mor-Avi, V., Weinert, L., et al. Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference. Circulation 114 (2006), 654–661.
    • (2006) Circulation , vol.114 , pp. 654-661
    • Sugeng, L.1    Mor-Avi, V.2    Weinert, L.3
  • 3
    • 84865093929 scopus 로고    scopus 로고
    • Real-time 3D echocardiographic quantification of left atrial volume: multicenter study for validation with CMR
    • 3 Mor-Avi, V., Yodwut, C., Jenkins, C., et al. Real-time 3D echocardiographic quantification of left atrial volume: multicenter study for validation with CMR. J Am Coll Cardiol Img 5 (2012), 769–777.
    • (2012) J Am Coll Cardiol Img , vol.5 , pp. 769-777
    • Mor-Avi, V.1    Yodwut, C.2    Jenkins, C.3
  • 4
    • 84055198661 scopus 로고    scopus 로고
    • EAE/ASE recommendations for image acquisition and display using three-dimensional echocardiography
    • 4 Lang, R.M., Badano, L.P., Tsang, W., et al. EAE/ASE recommendations for image acquisition and display using three-dimensional echocardiography. J Am Soc Echocardiogr 25 (2012), 3–46.
    • (2012) J Am Soc Echocardiogr , vol.25 , pp. 3-46
    • Lang, R.M.1    Badano, L.P.2    Tsang, W.3
  • 5
    • 84925515752 scopus 로고    scopus 로고
    • Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging
    • 5 Lang, R.M., Badano, L.P., Mor-Avi, V., et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc Echocardiogr 28 (2015), 1–39.e14.
    • (2015) J Am Soc Echocardiogr , vol.28 , pp. 1-39.e14
    • Lang, R.M.1    Badano, L.P.2    Mor-Avi, V.3
  • 6
    • 84870441475 scopus 로고    scopus 로고
    • Sources of variation and bias in assessing left ventricular volumes and dyssynchrony using three-dimensional echocardiography
    • 6 Muraru, D., Badano, L.P., Ermacora, D., Piccoli, G., Iliceto, S., Sources of variation and bias in assessing left ventricular volumes and dyssynchrony using three-dimensional echocardiography. Int J Cardiovasc Imaging 28 (2012), 1357–1368.
    • (2012) Int J Cardiovasc Imaging , vol.28 , pp. 1357-1368
    • Muraru, D.1    Badano, L.P.2    Ermacora, D.3    Piccoli, G.4    Iliceto, S.5
  • 7
    • 84886725241 scopus 로고    scopus 로고
    • Interinstitutional measurements of left ventricular volumes, speckle-tracking strain, and dyssynchrony using three-dimensional echocardiography
    • 7 Tsang, W., Kenny, C., Adhya, S., et al. Interinstitutional measurements of left ventricular volumes, speckle-tracking strain, and dyssynchrony using three-dimensional echocardiography. J Am Soc Echocardiogr 26 (2013), 1253–1257.
    • (2013) J Am Soc Echocardiogr , vol.26 , pp. 1253-1257
    • Tsang, W.1    Kenny, C.2    Adhya, S.3
  • 8
    • 79960843071 scopus 로고    scopus 로고
    • Feasibility of single-beat full-volume capture real-time three-dimensional echocardiography and auto-contouring algorithm for quantification of left ventricular volume: validation with cardiac magnetic resonance imaging
    • 8 Chang, S.A., Lee, S.C., Kim, E.Y., et al. Feasibility of single-beat full-volume capture real-time three-dimensional echocardiography and auto-contouring algorithm for quantification of left ventricular volume: validation with cardiac magnetic resonance imaging. J Am Soc Echocardiogr 24 (2011), 853–859.
    • (2011) J Am Soc Echocardiogr , vol.24 , pp. 853-859
    • Chang, S.A.1    Lee, S.C.2    Kim, E.Y.3
  • 9
    • 84863342262 scopus 로고    scopus 로고
    • Feasibility, accuracy, and reproducibility of real-time full-volume 3D transthoracic echocardiography to measure LV volumes and systolic function: a fully automated endocardial contouring algorithm in sinus rhythm and atrial fibrillation
    • 9 Thavendiranathan, P., Liu, S., Verhaert, D., et al. Feasibility, accuracy, and reproducibility of real-time full-volume 3D transthoracic echocardiography to measure LV volumes and systolic function: a fully automated endocardial contouring algorithm in sinus rhythm and atrial fibrillation. J Am Coll Cardiol Img 5 (2012), 239–251.
    • (2012) J Am Coll Cardiol Img , vol.5 , pp. 239-251
    • Thavendiranathan, P.1    Liu, S.2    Verhaert, D.3
  • 10
    • 84885578213 scopus 로고    scopus 로고
    • Novel single-beat full-volume capture real-time three-dimensional echocardiography and auto-contouring algorithm for quantification of left ventricular volume: validation with cardiac magnetic resonance imaging
    • 10 Zhang, Q.B., Sun, J.P., Gao, R.F., et al. Novel single-beat full-volume capture real-time three-dimensional echocardiography and auto-contouring algorithm for quantification of left ventricular volume: validation with cardiac magnetic resonance imaging. Int J Cardiol 168 (2013), 2946–2948.
    • (2013) Int J Cardiol , vol.168 , pp. 2946-2948
    • Zhang, Q.B.1    Sun, J.P.2    Gao, R.F.3
  • 11
    • 77955499761 scopus 로고    scopus 로고
    • Single-beat versus multibeat real-time 3D echocardiography for assessing left ventricular volumes and ejection fraction: a comparison study with cardiac magnetic resonance
    • 11 Macron, L., Lim, P., Bensaid, A., et al. Single-beat versus multibeat real-time 3D echocardiography for assessing left ventricular volumes and ejection fraction: a comparison study with cardiac magnetic resonance. Circ Cardiovasc Imaging 3 (2010), 450–455.
    • (2010) Circ Cardiovasc Imaging , vol.3 , pp. 450-455
    • Macron, L.1    Lim, P.2    Bensaid, A.3
  • 12
    • 50249143000 scopus 로고    scopus 로고
    • Relative importance of errors in left ventricular quantitation by two-dimensional echocardiography: insights from three-dimensional echocardiography and cardiac magnetic resonance imaging
    • 12 Chukwu, E.O., Barasch, E., Mihalatos, D.G., et al. Relative importance of errors in left ventricular quantitation by two-dimensional echocardiography: insights from three-dimensional echocardiography and cardiac magnetic resonance imaging. J Am Soc Echocardiogr 21 (2008), 990–997.
    • (2008) J Am Soc Echocardiogr , vol.21 , pp. 990-997
    • Chukwu, E.O.1    Barasch, E.2    Mihalatos, D.G.3
  • 13
    • 78650113495 scopus 로고    scopus 로고
    • A meta-analysis and investigation for the source of bias of left ventricular volumes and function by three-dimensional echocardiography in comparison with magnetic resonance imaging
    • 13 Shimada, Y.J., Shiota, T., A meta-analysis and investigation for the source of bias of left ventricular volumes and function by three-dimensional echocardiography in comparison with magnetic resonance imaging. Am J Cardiol 107 (2011), 126–138.
    • (2011) Am J Cardiol , vol.107 , pp. 126-138
    • Shimada, Y.J.1    Shiota, T.2
  • 14
    • 84872033896 scopus 로고    scopus 로고
    • Reproducibility of echocardiographic techniques for sequential assessment of left ventricular ejection fraction and volumes: application to patients undergoing cancer chemotherapy
    • 14 Thavendiranathan, P., Grant, A.D., Negishi, T., Plana, J.C., Popovic, Z.B., Marwick, T.H., Reproducibility of echocardiographic techniques for sequential assessment of left ventricular ejection fraction and volumes: application to patients undergoing cancer chemotherapy. J Am Coll Cardiol 61 (2013), 77–84.
    • (2013) J Am Coll Cardiol , vol.61 , pp. 77-84
    • Thavendiranathan, P.1    Grant, A.D.2    Negishi, T.3    Plana, J.C.4    Popovic, Z.B.5    Marwick, T.H.6
  • 15
    • 84859785202 scopus 로고    scopus 로고
    • Underestimation of left atrial volume by three-dimensional echocardiography validated by magnetic resonance imaging: a meta-analysis and investigation of the source of bias
    • 15 Shimada, Y.J., Shiota, T., Underestimation of left atrial volume by three-dimensional echocardiography validated by magnetic resonance imaging: a meta-analysis and investigation of the source of bias. Echocardiography 29 (2012), 385–390.
    • (2012) Echocardiography , vol.29 , pp. 385-390
    • Shimada, Y.J.1    Shiota, T.2
  • 16
    • 64649092670 scopus 로고    scopus 로고
    • Left atrial volume measurement with automated border detection by 3-dimensional echocardiography: comparison with magnetic resonance imaging
    • 16 Artang, R., Migrino, R.Q., Harmann, L., Bowers, M., Woods, T.D., Left atrial volume measurement with automated border detection by 3-dimensional echocardiography: comparison with magnetic resonance imaging. Cardiovasc Ultrasound, 7, 2009, 16.
    • (2009) Cardiovasc Ultrasound , vol.7 , pp. 16
    • Artang, R.1    Migrino, R.Q.2    Harmann, L.3    Bowers, M.4    Woods, T.D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.