메뉴 건너뛰기




Volumn 43, Issue 10, 2011, Pages 2947-2955

Energy and environmental performance of building faç ades integrated with phase change material in subtropical Hong Kong

Author keywords

Building fa ade; EnergyPlus; Payback period; Phase change material

Indexed keywords

AIR CONDITIONING; BUILDING MATERIALS; ENERGY CONSERVATION; ENVIRONMENTAL MANAGEMENT; GREENHOUSE GASES; HOUSING; INVESTMENTS; PHASE CHANGE MATERIALS;

EID: 84988290595     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2011.07.021     Document Type: Article
Times cited : (123)

References (26)
  • 1
    • 78649330915 scopus 로고    scopus 로고
    • Experimental investigation of energy saving in buildings with PCM cold storage
    • U. Strith, V. Butala, Experimental investigation of energy saving in buildings with PCM cold storage, International Journal of Refrigeration 33 (2010) 1676-1683.
    • (2010) International Journal of Refrigeration , vol.33 , pp. 1676-1683
    • Strith, U.1    Butala, V.2
  • 2
    • 77955324706 scopus 로고    scopus 로고
    • Energy efficient PCM-based variable air volume air conditioning system for modern buildings
    • R. Parameshwaran, S. Harikrishnan, S. Kalaiselvam, Energy efficient PCM-based variable air volume air conditioning system for modern buildings, Energy and Buildings 42 (2010) 1353-1360.
    • (2010) Energy and Buildings , vol.42 , pp. 1353-1360
    • Parameshwaran, R.1    Harikrishnan, S.2    Kalaiselvam, S.3
  • 3
    • 34548220059 scopus 로고    scopus 로고
    • Free cooling of a building using PCM heat storage integrated into the ventilation system
    • DOI 10.1016/j.solener.2007.01.010, PII S0038092X07000308, CISBAT 2005
    • C. Arkar, S. Medved, Free cooling of a building usingPCMheat storage integrated into the ventilation system, Solar Energy 81 (2007) 1078-1087. (Pubitemid 47320693)
    • (2007) Solar Energy , vol.81 , Issue.9 , pp. 1078-1087
    • Arkar, C.1    Medved, S.2
  • 4
    • 33749410377 scopus 로고    scopus 로고
    • The evaluation of peak shaving by a thermal storage system using phase-change materials in air distribution systems
    • M. Yamaha, S. Misaki, The evaluation of peak shaving by a thermal storage system using phase-change materials in air distribution systems, HVAC & R Research 12 (2006) 861-869. (Pubitemid 44501637)
    • (2006) HVAC and R Research , vol.12 , Issue.3 C , pp. 861-869
    • Yamaha, M.1    Misaki, S.2
  • 5
    • 12444306322 scopus 로고    scopus 로고
    • PCM-façade-panel for daylighting and room heating
    • H. Weinläder, A. Beck, J. Fricke, PCM-façade-panel for daylighting and room heating, Solar Energy 78 (2005) 177-186.
    • (2005) Solar Energy , vol.78 , pp. 177-186
    • Weinläder, H.1    Beck, A.2    Fricke, J.3
  • 6
    • 0142153034 scopus 로고    scopus 로고
    • Numerical analysis of the thermal behaviour of glazed ventilated facades in Mediterranean climates. Part II: Applications and analysis of results
    • DOI 10.1016/j.solener.2003.07.014
    • D. Faggembauu, M. Costa, M. Soria, A. Oliva, Numerical analysis of the thermal behaviour of ventilated glazed facades in Mediterranean climates, Part II: Applications and analysis of results, Solar Energy 75 (2003) 229-239. (Pubitemid 37365707)
    • (2003) Solar Energy , vol.75 , Issue.3 , pp. 229-239
    • Faggembauu, D.1    Costa, M.2    Soria, M.3    Oliva, A.4
  • 7
    • 33646683384 scopus 로고    scopus 로고
    • Research on thermal storage using rock wool phase-change material ceiling board
    • ASHRAE Transactions - Technical and Symposium Papers presented at the 2006 Winter Meeting of the American Society of Heating, Refrigerating and Air-Conditioning Engineers
    • T. Kondo, T. Lbamoto, Research on thermal storage using rock wool phasechange material ceiling board, ASHRAE Transactions 112 (2006) 526-531. (Pubitemid 43735388)
    • (2006) ASHRAE Transactions , vol.112 PART 1 , pp. 526-531
    • Kondo, T.1    Ibamoto, T.2
  • 8
    • 33646704544 scopus 로고    scopus 로고
    • Diurnal load reduction through phase-change building components
    • ASHRAE Transactions - Technical and Symposium Papers presented at the 2006 Winter Meeting of the American Society of Heating, Refrigerating and Air-Conditioning Engineers
    • J.K. Kissock, S. Limas, Diurnal load reduction through phase-change building components, ASHRAE Transactions 112 (2006) 509-517. (Pubitemid 43735386)
    • (2006) ASHRAE Transactions , vol.112 PART 1 , pp. 509-517
    • Kissock, K.1    Limas, S.2
  • 9
    • 38349089388 scopus 로고    scopus 로고
    • Experimental investigation and numerical simulation analysis on the thermal performance of a building roof incorporating phase change material (PCM) for thermal management
    • A. Pasupathy, L. Athanasius, R. Velraj, R.V. Seeniraj, Experimental investigation and numerical simulation analysis on the thermal performance of a building roof incorporating phase change material (PCM) for thermal management, Applied Thermal Engineering 28 (2008) 556-565.
    • (2008) Applied Thermal Engineering , vol.28 , pp. 556-565
    • Pasupathy, A.1    Athanasius, L.2    Velraj, R.3    Seeniraj, R.V.4
  • 10
    • 33644759172 scopus 로고    scopus 로고
    • Study of a floor supply air conditioning system using granular phase change material to augment building mass thermal storage - Heat response in small scale experiments
    • DOI 10.1016/j.enbuild.2005.07.010, PII S037877880500143X
    • K. Nagano, S. Takeda, T. Mochida, K. Shimakura, T. Nakamura, Study of a floor supply air conditioning system using granular phase change material to augment building mass thermal storage-heat response in small scale experiments, Energy and Buildings 38 (2006) 436-446. (Pubitemid 43343823)
    • (2006) Energy and Buildings , vol.38 , Issue.5 , pp. 436-446
    • Nagano, K.1    Takeda, S.2    Mochida, T.3    Shimakura, K.4    Nakamura, T.5
  • 11
    • 27744501598 scopus 로고    scopus 로고
    • Phase-change wallboard and mechanical night ventilation in commercial buildings
    • University of California
    • C. Stetiu, H.E. Feustel, Phase-change wallboard and mechanical night ventilation in commercial buildings, Lawrence Berkeley National Laboratory, University of California 1998.
    • (1998) Lawrence Berkeley National Laboratory
    • Stetiu, C.1    Feustel, H.E.2
  • 12
    • 64849110980 scopus 로고    scopus 로고
    • Experimental assessment of a phase change material for wall building use
    • F. Kuznik, J. Virgone, Experimental assessment of a phase change material for wall building use, Applied Energy 86 (2009) 2038-2046.
    • (2009) Applied Energy , vol.86 , pp. 2038-2046
    • Kuznik, F.1    Virgone, J.2
  • 13
    • 34447249059 scopus 로고    scopus 로고
    • Experimental study and evaluation of latent heat storage in phase change materials wallboards
    • DOI 10.1016/j.enbuild.2006.11.012, PII S0378778806002957
    • L. Shilei, F. Guohui, Z. Neng, D. Li, Experimental study and evaluation of latent heat storage in phase change materials wallboards, Energy and Buildings 39 (2007) 1088-1091. (Pubitemid 47043369)
    • (2007) Energy and Buildings , vol.39 , Issue.10 , pp. 1088-1091
    • Shilei, L.1    Guohui, F.2    Neng, Z.3    Li, D.4
  • 14
    • 77649183812 scopus 로고    scopus 로고
    • Experimental study of using PCM in brick constructive solutions for passive cooling
    • A. Castell, I. Martorell, M. Medrano, G. Perez, L.R. Cabeza, Experimental study of using PCM in brick constructive solutions for passive cooling, Energy and Buildings 42 (2010) 534-540.
    • (2010) Energy and Buildings , vol.42 , pp. 534-540
    • Castell, A.1    Martorell, I.2    Medrano, M.3    Perez, G.4    Cabeza, L.R.5
  • 15
    • 77950860427 scopus 로고    scopus 로고
    • Cooling strategies, summer comfort and energy performance of a rehabilitated passive standard office building
    • U. Eicker, Cooling strategies, summer comfort and energy performance of a rehabilitated passive standard office building, Applied Energy 87 (2010) 2031-2039.
    • (2010) Applied Energy , vol.87 , pp. 2031-2039
    • Eicker, U.1
  • 16
    • 77950864369 scopus 로고    scopus 로고
    • Evaluation of the thermal performance of frame walls enhanced with paraffin and hydrated salt phase change materials using a dynamic wall simulator
    • A.C. Evers, M.A. Medina, Y. Fang, Evaluation of the thermal performance of frame walls enhanced with paraffin and hydrated salt phase change materials using a dynamic wall simulator, Building and Environment 45 (2010) 1762-1768.
    • (2010) Building and Environment , vol.45 , pp. 1762-1768
    • Evers, A.C.1    Medina, M.A.2    Fang, Y.3
  • 17
    • 41549108149 scopus 로고    scopus 로고
    • Optimization of a phase change material wallboard for building use
    • F. Kuznik, J. Virgone, J. Noel, Optimization of a phase change material wallboard for building use, Applied Thermal Engineering 28 (2008) 1291-1298.
    • (2008) Applied Thermal Engineering , vol.28 , pp. 1291-1298
    • Kuznik, F.1    Virgone, J.2    Noel, J.3
  • 20
    • 44349164431 scopus 로고    scopus 로고
    • Raising evaporative cooling potentials using combined cooled ceiling and MPCM slurry storage
    • DOI 10.1016/j.enbuild.2008.02.028, PII S0378778808000583
    • X. Wang, J. Niu, A.H.C. Passsen, Raising evaporative cooling potentials using combined cooled ceiling and MPCM slurry storage, Energy and Buildings 40 (2008) 1691-1698. (Pubitemid 351749546)
    • (2008) Energy and Buildings , vol.40 , Issue.9 , pp. 1691-1698
    • Wang, X.1    Niu, J.2    Van Paassen, A.H.C.3
  • 21
    • 79959816675 scopus 로고    scopus 로고
    • EnergyPlus Development Team Input Output Reference: The Encyclopedic Reference to EnergyPlus Input and Output
    • EnergyPlus Development Team, Input Output Reference: The Encyclopedic Reference to EnergyPlus Input and Output, EnergyPlus Version 6.0 (2010).
    • (2010) EnergyPlus Version 6.0
  • 22
    • 85043030515 scopus 로고    scopus 로고
    • DuPont Energain Energy-saving thermal mass systems, DuPont de Nemours (Luxembourg).
    • DuPont Energain, Energy-saving thermal mass systems, DuPont de Nemours (Luxembourg). http://www.energain.dupont.com.
  • 23
    • 85043046547 scopus 로고    scopus 로고
    • DuPont Energain Examples of residential and non-residential buildings with Energain® product to improve room climate and energy efficiency of the building, DuPont de Nemours (Luxembourg).
    • DuPont Energain, Examples of residential and non-residential buildings with Energain® product to improve room climate and energy efficiency of the building, DuPont de Nemours (Luxembourg). http://energain.co.uk/Energain/en GB/references/index.html.
  • 24
    • 24944467894 scopus 로고    scopus 로고
    • Generation of a typical meteorological year for Hong Kong
    • DOI 10.1016/j.enconman.2005.02.010, PII S0196890405000543
    • A.L.S. Chan, T.T. Chow, K.F. Fong, Z. Lin, Generation of a typical meteorological year for Hong Kong, Energy Conversion and Management 83 (1) (2006) 87-96. (Pubitemid 41312925)
    • (2006) Energy Conversion and Management , vol.47 , Issue.1 , pp. 87-96
    • Chan, A.L.S.1    Chow, T.T.2    Fong, S.K.F.3    Lin, J.Z.4
  • 26
    • 85043061289 scopus 로고    scopus 로고
    • Guidelines to account for and report on greenhouse gas emissions and removals for buildings (commercial, residential or institutional purposes) in Hong Kong, 2010 Edition, Electrical and Mechanical Services Department and Environmental Protection Department, The Government of Hong Kong Special Administrative Region
    • Guidelines to account for and report on greenhouse gas emissions and removals for buildings (commercial, residential or institutional purposes) in Hong Kong, 2010 Edition, Electrical and Mechanical Services Department and Environmental Protection Department, The Government of Hong Kong Special Administrative Region.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.