메뉴 건너뛰기




Volumn 23, Issue 4, 2016, Pages 2223-2231

Partial discharge detection in 11.4 kV cast resin power transformer

Author keywords

coil; Partial discharge; time domain detection; winding

Indexed keywords

POWER TRANSFORMERS; RESINS; WINDING;

EID: 84986891103     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2016.7556498     Document Type: Article
Times cited : (15)

References (26)
  • 1
    • 33847740252 scopus 로고    scopus 로고
    • A novel wavelet transform technique for on-line partial discharge measurements part 1: Wt de-noising algorithm
    • H. Zhang, T. R. Blackburn, B. T. Phung and D. Sen, "A novel wavelet transform technique for on-line partial discharge measurements, part 1: wt de-noising algorithm," IEEE Trans. Dielectr. Electr. Insul., Vol. 14, No. 1, pp. 3-13, 2007
    • (2007) IEEE Trans. Dielectr. Electr. Insul , vol.14 , Issue.1 , pp. 3-13
    • Zhang, H.1    Blackburn, T.R.2    Phung, B.T.3    Sen, D.4
  • 2
    • 33847729836 scopus 로고    scopus 로고
    • Partial discharge inception and propagation characteristics of magnet wire for inverter-fed motor under surge voltage application
    • N. Hayakawa, M. Morikawa and H. Okubo, "Partial discharge inception and propagation characteristics of magnet wire for inverter-fed motor under surge voltage application," IEEE Trans. Dielectr. Electr. Insul., Vol. 14, No. 1, pp. 39-45, 2007
    • (2007) IEEE Trans. Dielectr. Electr. Insul , vol.14 , Issue.1 , pp. 39-45
    • Hayakawa, N.1    Morikawa, M.2    Okubo, H.3
  • 4
    • 84903185807 scopus 로고    scopus 로고
    • Partial discharge in electric motor fed by a PWM inverter: Off-line and on-line detection
    • T. Billard, T. Lebey and F. Fresnet, "Partial discharge in electric motor fed by a PWM inverter: off-line and on-line detection", IEEE Trans. Dielectr. Electr. Insul., Vol. 21, No. 3, pp. 1235-1242, 2014
    • (2014) IEEE Trans. Dielectr. Electr. Insul , vol.21 , Issue.3 , pp. 1235-1242
    • Billard, T.1    Lebey, T.2    Fresnet, F.3
  • 5
    • 84961942633 scopus 로고    scopus 로고
    • Relative ability of UHF antenna and VHF capacitor methods to detect partial discharge in turbine generator stator windings
    • G.C. Stone, C. Chan and H.G. Sedding, "Relative ability of UHF antenna and VHF capacitor methods to detect partial discharge in turbine generator stator windings", IEEE Trans. Dielectr. Electr. Insul., Vol. 22, No. 6, pp. 3069-3078, 2015
    • (2015) IEEE Trans. Dielectr. Electr. Insul , vol.22 , Issue.6 , pp. 3069-3078
    • Stone, G.C.1    Chan, C.2    Sedding, H.G.3
  • 6
    • 33847740251 scopus 로고    scopus 로고
    • Study on mathematical model for VHF partial discharge of typical insulated defects in GIS
    • J. Tang, Q. Zhou, M. Tang and Y. Xie, "Study on mathematical model for VHF partial discharge of typical insulated defects in GIS," IEEE Trans. Dielectr. Electr. Insul., Vol. 14, No. 1, pp. 30-38, 2007
    • (2007) IEEE Trans. Dielectr. Electr. Insul , vol.14 , Issue.1 , pp. 30-38
    • Tang, J.1    Zhou, Q.2    Tang, M.3    Xie, Y.4
  • 7
    • 0025451654 scopus 로고
    • Partial discharge: Overview and signal generation
    • S. A. Boggs, "Partial discharge: overview and signal generation," IEEE Electr. Insul. Mag., Vol. 6, No. 4, pp. 33-39, 1990
    • (1990) IEEE Electr. Insul. Mag , vol.6 , Issue.4 , pp. 33-39
    • Boggs, S.A.1
  • 8
    • 0036759963 scopus 로고    scopus 로고
    • Recognition of discharge sources using UHF PD signatures
    • K. Raja, F. Devaux and S. Lelaidier, "Recognition of discharge sources using UHF PD signatures," IEEE Electr. Insul. Mag., Vol. 18, No. 5, pp. 8-14, 2002
    • (2002) IEEE Electr. Insul. Mag , vol.18 , Issue.5 , pp. 8-14
    • Raja, K.1    Devaux, F.2    Lelaidier, S.3
  • 9
    • 0026853416 scopus 로고
    • Digital techniques for partial discharge measurements
    • B. H. Ward, "Digital techniques for partial discharge measurements," IEEE Trans. Power Delivery, Vol. 7, No. 2, pp. 469-479, 1992
    • (1992) IEEE Trans. Power Delivery , vol.7 , Issue.2 , pp. 469-479
    • Ward, B.H.1
  • 10
    • 0027634116 scopus 로고
    • Partial discharge XVII: The early history of partial discharge research
    • D. A. Nattrass, "Partial discharge XVII: The early history of partial discharge research," IEEE Electr. Insul. Mag., Vol. 9, No. 4, pp. 27-30, 1993
    • (1993) IEEE Electr. Insul. Mag , vol.9 , Issue.4 , pp. 27-30
    • Nattrass, D.A.1
  • 11
    • 55149124192 scopus 로고    scopus 로고
    • Study of partial discharge measurement in power equipment using acoustic technique and wavelet transform
    • L. J. Chen, W. M. Lin, T. P. Tsao, and Y. H. Lin, "Study of partial discharge measurement in power equipment using acoustic technique and wavelet transform," IEEE Trans. Power Delivery, Vol. 22, No. 3, pp. 1575-1580, 2007
    • (2007) IEEE Trans. Power Delivery , vol.22 , Issue.3 , pp. 1575-1580
    • Chen, L.J.1    Lin, W.M.2    Tsao, T.P.3    Lin, Y.H.4
  • 12
    • 0036079176 scopus 로고    scopus 로고
    • Comparative investigations on UHF and acoustic PD detection sensitivity in transformers
    • K. Raja and T. Floribert, "Comparative investigations on UHF and acoustic PD detection sensitivity in transformers," IEEE Intl. Sympos. Electr. Insul., pp. 150-153, 2002
    • (2002) IEEE Intl. Sympos. Electr. Insul , pp. 150-153
    • Raja, K.1    Floribert, T.2
  • 13
    • 84872148244 scopus 로고    scopus 로고
    • Location of PD sources in power transformers by UHF and acoustic measurements
    • S. Coenen and S. Tenbohlen, "Location of PD sources in power transformers by UHF and acoustic measurements", IEEE Trans. Dielectr. Electr. Insul., Vol. 19, No. 6, pp. 1934-1940, 2012
    • (2012) IEEE Trans. Dielectr. Electr. Insul , vol.19 , Issue.6 , pp. 1934-1940
    • Coenen, S.1    Tenbohlen, S.2
  • 14
    • 84855702544 scopus 로고    scopus 로고
    • Electromagnetic waves from partial discharges in windings and their detection by patch antenna
    • Y.Shibuya, S. Matsumoto, T. Konno and K. Umezu, "Electromagnetic waves from partial discharges in windings and their detection by patch antenna", IEEE Trans. Dielectr. Electr. Insul., Vol. 18, No. 6, pp. 2013-2023, 2011
    • (2011) IEEE Trans. Dielectr. Electr. Insul , vol.18 , Issue.6 , pp. 2013-2023
    • Shibuya, Y.1    Matsumoto, S.2    Konno, T.3    Umezu, K.4
  • 15
    • 84860112302 scopus 로고    scopus 로고
    • Partial discharge signal propagation characteristics inside the winding of oil-immersed power transformer using the equivalent circuit of winding model in the oil
    • S. Okabe, G. Uetaand H.Wada, "Partial discharge signal propagation characteristics inside the winding of oil-immersed power transformer using the equivalent circuit of winding model in the oil", IEEE Trans. Dielectr. Electr. Insul., Vol. 19, No. 2, pp. 472-480, 2012
    • (2012) IEEE Trans. Dielectr. Electr. Insul , vol.19 , Issue.2 , pp. 472-480
    • Okabe, S.1    Uetaand, G.2    Wada, H.3
  • 16
    • 23944440123 scopus 로고    scopus 로고
    • Radiometric location of partial discharge sources on energized high-voltage plant
    • P. J. Moore, I. E. Portugues, and I. A. Glover, "Radiometric location of partial discharge sources on energized high-voltage plant", IEEE Trans. on Power Delivery, Vol. 20, No. 3, pp. 2264-2272, 2005
    • (2005) IEEE Trans. on Power Delivery , vol.20 , Issue.3 , pp. 2264-2272
    • Moore, P.J.1    Portugues, I.E.2    Glover, I.A.3
  • 17
    • 0036693153 scopus 로고    scopus 로고
    • Appling UHF partial discharge detection to power transformers
    • M. D. Judd, G. F. Cleary, and C. J. Bennoch, "Appling UHF partial discharge detection to power transformers," IEEE Power Eng. Rev., Vol. 22, No. 8, pp. 57-59, 2002
    • (2002) IEEE Power Eng. Rev , vol.22 , Issue.8 , pp. 57-59
    • Judd, M.D.1    Cleary, G.F.2    Bennoch, C.J.3
  • 18
    • 84860294283 scopus 로고    scopus 로고
    • External sensors in partial discharge ultra-high-frequency measurements in gas-insulated substations
    • Ju Tang, Gang Wei and Xiaoxing Zhang, "External sensors in partial discharge ultra-high-frequency measurements in gas-insulated substations" Europ. Trans. Electr. Power, Vol.22, No. 4, pp. 559, 2012
    • (2012) Europ. Trans. Electr. Power , vol.22 , Issue.4 , pp. 559
    • Tang, J.1    Wei, G.2    Zhang, X.3
  • 19
    • 77954876190 scopus 로고    scopus 로고
    • Understanding the partial discharge activity of conducting particles in GIS under DC voltages using the UHF technique
    • R. Sarathi and R. Umamaheswari, "Understanding the partial discharge activity of conducting particles in GIS under DC voltages using the UHF technique" Europ. Trans. Electr. Power, Vol.20, No.5, pp.591, 2010
    • (2010) Europ. Trans. Electr. Power , vol.20 , Issue.5 , pp. 591
    • Sarathi, R.1    Umamaheswari, R.2
  • 20
    • 33845619445 scopus 로고    scopus 로고
    • Partial discharge location in power transformers using wideband RF detection
    • Z. Tang, C. Li, X. Cheng, W. Wang, J. Li, and J. Li, "Partial discharge location in power transformers using wideband RF detection" IEEE Trans. on Dielectr. Electr. Insul., Vol. 13, No. 6, pp. 1193-1199, 2006
    • (2006) IEEE Trans. on Dielectr. Electr. Insul , vol.13 , Issue.6 , pp. 1193-1199
    • Tang, Z.1    Li, C.2    Cheng, X.3    Wang, W.4    Li, J.5    Li, J.6
  • 21
    • 1542359634 scopus 로고    scopus 로고
    • A non-intrusive partial discharge measurement system based on RF technology
    • Toronto, ON, Canada Jul
    • P. J. Moore, I. E. Portugues and I. A. Glover, "A non-intrusive partial discharge measurement system based on RF technology," IEEE Power Eng. Soc. General Meeting, Toronto, ON, Canada, Jul. 2003, 0-7803-7989-6
    • (2003) IEEE Power Eng. Soc. General Meeting , pp. 07803-79896
    • Moore, P.J.1    Portugues, I.E.2    Glover, I.A.3
  • 22
    • 77249169254 scopus 로고    scopus 로고
    • J.A frequency-based RF partial discharge detector for low-power wireless sensing
    • P.C. Baker, M.D. Juddand and S.D.J. McArthur, "J.A frequency-based RF partial discharge detector for low-power wireless sensing" IEEE Trans. Dielectr. Electr. Insul., Vol. 17, No. 1, pp. 133-140, 2010
    • (2010) IEEE Trans. Dielectr. Electr. Insul , vol.17 , Issue.1 , pp. 133-140
    • Baker, P.C.1    Juddand, M.D.2    McArthur, S.D.J.3
  • 23
    • 84898432494 scopus 로고    scopus 로고
    • RF-based monitoring and classification of partial discharge on wet silicone rubber surface
    • I. Shurrab, A. El-hag, K. Assaleh, R. Ghunem and S. Jayaram, " RF-based monitoring and classification of partial discharge on wet silicone rubber surface", IEEE Trans. Dielectr. Electr. Insul., Vol. 20, No. 6, pp. 2188-2194, 2013
    • (2013) IEEE Trans. Dielectr. Electr. Insul , vol.20 , Issue.6 , pp. 2188-2194
    • Shurrab, I.1    El-Hag, A.2    Assaleh, K.3    Ghunem, R.4    Jayaram, S.5
  • 26
    • 84903187141 scopus 로고    scopus 로고
    • Partial discharge detection by RF coil in 161-kV power transformer
    • Mu-Kuen Chen, Jeng-Ming Chen and Chao-Yuan Cheng, "Partial discharge detection by RF coil in 161-kV power transformer", IEEE Trans. Dielectr. Electr. Insul., Vol. 21, No. 3, pp. 1405-1414, 2014
    • (2014) IEEE Trans. Dielectr. Electr. Insul , vol.21 , Issue.3 , pp. 1405-1414
    • Chen, M.1    Chen, J.2    Cheng, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.