Volumn 237, Issue , 2016, Pages 132-137

Single-use, electricity-free amplification device for detection of HIV-1

Author keywords

Diagnosis; HIV 1; Nucleic acid amplification; Point of care; RNA

Indexed keywords

ARTICLE; BLOOD SAMPLING; CHEMICAL REACTION; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DISPOSABLE EQUIPMENT; EARLY DIAGNOSIS; FREEZE DRYING; HUMAN; HUMAN IMMUNODEFICIENCY VIRUS 1; HUMAN IMMUNODEFICIENCY VIRUS 1 INFECTION; NON INSTRUMENTED NUCLEIC ACID AMPLIFICATION SINGLE USE DISPOSABLE DEVICE; NUCLEIC ACID AMPLIFICATION; NUCLEIC ACID ANALYSIS; POINT OF CARE SYSTEM; POINT OF CARE TESTING; POLYMERASE CHAIN REACTION SYSTEM; PRIORITY JOURNAL; REPRODUCIBILITY; REVERSE TRANSCRIPTION LOOP MEDIATED ISOTHERMAL AMPLIFICATION; REVERSE TRANSCRIPTION POLYMERASE CHAIN REACTION; STORAGE TEMPERATURE; VIRUS DETECTION; BLOOD; DEVICES; ELECTRICITY; EVALUATION STUDY; GENETICS; HEAT; HIV INFECTIONS; ISOLATION AND PURIFICATION; PROCEDURES; SENSITIVITY AND SPECIFICITY; VIROLOGY;

EID: 84986551058     PISSN: 01660934     EISSN: 18790984     Source Type: Journal    
DOI: 10.1016/j.jviromet.2016.09.007     Document Type: Article
Times cited : (31)

References (24)
  • 1
    • 40949106494 scopus 로고    scopus 로고
    • State of the art for diagnosis of HIV infection
    • Branson, B.M., State of the art for diagnosis of HIV infection. Clin. Infect. Dis. 45:Suppl. 4 (2007), S221–S225.
    • (2007) Clin. Infect. Dis. , vol.45 , pp. S221-S225
    • Branson, B.M.1
  • 4
    • 46949094566 scopus 로고    scopus 로고
    • Rapid detection of HIV-1 by reverse-transcription, loop-mediated isothermal amplification (RT-LAMP)
    • Curtis, K.A., Rudolph, D.L., Owen, S.M., Rapid detection of HIV-1 by reverse-transcription, loop-mediated isothermal amplification (RT-LAMP). J. Virol. Methods 151 (2008), 264–270.
    • (2008) J. Virol. Methods , vol.151 , pp. 264-270
    • Curtis, K.A.1    Rudolph, D.L.2    Owen, S.M.3
  • 5
    • 66449113153 scopus 로고    scopus 로고
    • Sequence-specific detection method for reverse transcription, loop-mediated isothermal amplification of HIV-1
    • Curtis, K.A., Rudolph, D.L., Owen, S.M., Sequence-specific detection method for reverse transcription, loop-mediated isothermal amplification of HIV-1. J. Med. Virol. 81 (2009), 966–972.
    • (2009) J. Med. Virol. , vol.81 , pp. 966-972
    • Curtis, K.A.1    Rudolph, D.L.2    Owen, S.M.3
  • 6
    • 65449166818 scopus 로고    scopus 로고
    • Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxy naphthol blue
    • Goto, M., Honda, E., Ogura, A., Nomoto, A., Hanaki, K., Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxy naphthol blue. Biotechniques 46 (2009), 167–172.
    • (2009) Biotechniques , vol.46 , pp. 167-172
    • Goto, M.1    Honda, E.2    Ogura, A.3    Nomoto, A.4    Hanaki, K.5
  • 7
    • 76249126232 scopus 로고    scopus 로고
    • Dried blood spots can expand access to virological monitoring of HIV treatment in resource-limited settings
    • Johannessen, A., Troseid, M., Calmy, A., Dried blood spots can expand access to virological monitoring of HIV treatment in resource-limited settings. J. Antimicrob. Chemother. 64 (2009), 1126–1129.
    • (2009) J. Antimicrob. Chemother. , vol.64 , pp. 1126-1129
    • Johannessen, A.1    Troseid, M.2    Calmy, A.3
  • 11
    • 77950930510 scopus 로고    scopus 로고
    • Simple amplification-based assay: a nucleic acid-based point-of-care platform for HIV-1 testing
    • Lee, H.H., Dineva, M.A., Chua, Y.L., Ritchie, A.V., Ushiro-Lumb, I., Wisniewski, C.A., Simple amplification-based assay: a nucleic acid-based point-of-care platform for HIV-1 testing. J. Infect. Dis. 201:Suppl. 1 (2010), S65–S72.
    • (2010) J. Infect. Dis. , vol.201 , pp. S65-S72
    • Lee, H.H.1    Dineva, M.A.2    Chua, Y.L.3    Ritchie, A.V.4    Ushiro-Lumb, I.5    Wisniewski, C.A.6
  • 14
    • 79955141396 scopus 로고    scopus 로고
    • An isothermal amplification reactor with an integrated isolation membrane for point-of-care detection of infectious diseases
    • Liu, C., Geva, E., Mauk, M., Qiu, X., Abrams, W.R., Malamud, D., Curtis, K., Owen, S.M., Bau, H.H., An isothermal amplification reactor with an integrated isolation membrane for point-of-care detection of infectious diseases. Analyst 136 (2011), 2069–2076.
    • (2011) Analyst , vol.136 , pp. 2069-2076
    • Liu, C.1    Geva, E.2    Mauk, M.3    Qiu, X.4    Abrams, W.R.5    Malamud, D.6    Curtis, K.7    Owen, S.M.8    Bau, H.H.9
  • 15
    • 30844461475 scopus 로고    scopus 로고
    • Sequence specific visual detection of LAMP reactions by addition of cationic polymers
    • Mori, Y., Hirano, T., Notomi, T., Sequence specific visual detection of LAMP reactions by addition of cationic polymers. BMC Biotechnol., 6, 2006, 3.
    • (2006) BMC Biotechnol. , vol.6 , pp. 3
    • Mori, Y.1    Hirano, T.2    Notomi, T.3
  • 16
    • 0035940965 scopus 로고    scopus 로고
    • Detection of loop-mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation
    • Mori, Y., Nagamine, K., Tomita, N., Notomi, T., Detection of loop-mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation. Biochem. Biophys. Res. Commun. 289 (2001), 150–154.
    • (2001) Biochem. Biophys. Res. Commun. , vol.289 , pp. 150-154
    • Mori, Y.1    Nagamine, K.2    Tomita, N.3    Notomi, T.4
  • 17
    • 0036599262 scopus 로고    scopus 로고
    • Accelerated reaction by loop-mediated isothermal amplification using loop primers
    • Nagamine, K., Hase, T., Notomi, T., Accelerated reaction by loop-mediated isothermal amplification using loop primers. Mol. Cell. Probes 16 (2002), 223–229.
    • (2002) Mol. Cell. Probes , vol.16 , pp. 223-229
    • Nagamine, K.1    Hase, T.2    Notomi, T.3
  • 18
    • 84941804483 scopus 로고    scopus 로고
    • Starting Antiretroviral Treatment Early Improves Outcomes for HIV-Infected Individuals
    • (accessed 07.24.15)
    • NIH, Starting Antiretroviral Treatment Early Improves Outcomes for HIV-Infected Individuals. 2015 http://www.niaid.nih.gov/news/newsreleases/2015/Pages/START.aspx (accessed 07.24.15).
    • (2015)
    • NIH1
  • 20
    • 84930646352 scopus 로고    scopus 로고
    • Detection of acute HIV-1 infection by RT-LAMP
    • Rudolph, D.L., Sullivan, V., Owen, S.M., Curtis, K.A., Detection of acute HIV-1 infection by RT-LAMP. PLoS One, 10, 2015, e0126609.
    • (2015) PLoS One , vol.10 , pp. e0126609
    • Rudolph, D.L.1    Sullivan, V.2    Owen, S.M.3    Curtis, K.A.4
  • 21
    • 84924143523 scopus 로고    scopus 로고
    • Evaluation of non-instrumented nucleic acid amplification by loop-mediated isothermal amplification (NINA-LAMP) for the diagnosis of malaria in Northwest Ethiopia
    • Sema, M., Alemu, A., Bayih, A.G., Getie, S., Getnet, G., Guelig, D., Burton, R., LaBarre, P., Pillai, D.R., Evaluation of non-instrumented nucleic acid amplification by loop-mediated isothermal amplification (NINA-LAMP) for the diagnosis of malaria in Northwest Ethiopia. Malar. J., 14, 2015, 44.
    • (2015) Malar. J. , vol.14 , pp. 44
    • Sema, M.1    Alemu, A.2    Bayih, A.G.3    Getie, S.4    Getnet, G.5    Guelig, D.6    Burton, R.7    LaBarre, P.8    Pillai, D.R.9
  • 23
    • 84922727461 scopus 로고    scopus 로고
    • Visual detection of isothermal nucleic acid amplification using pH-sensitive dyes
    • Tanner, N.A., Zhang, Y., Evans, T.C. Jr., Visual detection of isothermal nucleic acid amplification using pH-sensitive dyes. Biotechniques 58 (2015), 59–68.
    • (2015) Biotechniques , vol.58 , pp. 59-68
    • Tanner, N.A.1    Zhang, Y.2    Evans, T.C.3
  • 24
    • 77950931634 scopus 로고    scopus 로고
    • A rapid and automated sample-to-result HIV load test for near-patient application
    • Tanriverdi, S., Chen, L., Chen, S., A rapid and automated sample-to-result HIV load test for near-patient application. J. Infect. Dis. 201:Suppl. 1 (2010), S52–S58.
    • (2010) J. Infect. Dis. , vol.201 , pp. S52-S58
    • Tanriverdi, S.1    Chen, L.2    Chen, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.