Volumn 27, Issue 3, 2016, Pages 226-239

Detection and discrimination of tachycardia in ICDs manufactured by St. Jude Medical;Erkennung und Klassifizierung von Tachykardien bei ICDs von St. Jude Medical

Author keywords

Implantable cardioverter defibrillator; Sudden cardiac death; Tachyarrhythmia, ventricular; Tachycardia, supraventricular; Ventricular fibrillation

Indexed keywords

ALGORITHM; ARTICLE; ATRIAL FIBRILLATION; AUTOMATION; BIOMEDICAL TECHNOLOGY ASSESSMENT; DISEASE CLASSIFICATION; EQUIPMENT DESIGN; HEART ATRIUM FLUTTER; HEART VENTRICLE FIBRILLATION; HEART VENTRICLE TACHYCARDIA; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; MEDICAL DEVICE COMPLICATION; RISK REDUCTION; SENSITIVITY ANALYSIS; SINUS TACHYCARDIA; SUDDEN CARDIAC DEATH; SUPRAVENTRICULAR TACHYCARDIA; TACHYCARDIA; ARTIFACT; COMPUTER ASSISTED DIAGNOSIS; COMPUTER ASSISTED THERAPY; DEVICE FAILURE ANALYSIS; DEVICES; DISCRIMINANT ANALYSIS; ELECTROCARDIOGRAPHY; EVIDENCE BASED MEDICINE; HUMAN; MEDICAL ERROR; PREVENTION AND CONTROL; PROCEDURES; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; TACHYCARDIA, VENTRICULAR; TREATMENT OUTCOME;

EID: 84986272533     PISSN: 09387412     EISSN: 14351544     Source Type: Journal    
DOI: 10.1007/s00399-016-0455-1     Document Type: Article
Times cited : (10)

References (13)
  • 1
    • 0037306491 scopus 로고    scopus 로고
    • Clinical investigation of a new dual-chamber implantable cardioverter defibrillator with improved rhythm discrimination capabilities
    • PID: 12693494
    • Bailin SJ, Niebauer M, Tomassoni G et al (2003) Clinical investigation of a new dual-chamber implantable cardioverter defibrillator with improved rhythm discrimination capabilities. J Cardiovasc Electrophysiol 14:144–149
    • (2003) J Cardiovasc Electrophysiol , vol.14 , pp. 144-149
    • Bailin, S.J.1    Niebauer, M.2    Tomassoni, G.3
  • 2
    • 84947201448 scopus 로고    scopus 로고
    • Acceptance and psychological impact of implantable defibrillators amongst adults with congenital heart disease
    • PID: 25528316
    • Bedair R, Babu-Narayan SV, Dimopoulos K et al (2014) Acceptance and psychological impact of implantable defibrillators amongst adults with congenital heart disease. Int J Cardiol 181:218–224. doi:10.1016/j.ijcard.2014.12.028
    • (2014) Int J Cardiol , vol.181 , pp. 218-224
    • Bedair, R.1    Babu-Narayan, S.V.2    Dimopoulos, K.3
  • 3
    • 41149165849 scopus 로고    scopus 로고
    • Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II
    • PID: 18387436
    • Daubert JP, Zareba W, Cannom DS et al (2008) Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II. J Am Coll Cardiol 51:1357–1365. doi:10.1016/j.jacc.2007.09.073
    • (2008) J Am Coll Cardiol , vol.51 , pp. 1357-1365
    • Daubert, J.P.1    Zareba, W.2    Cannom, D.S.3
  • 4
    • 78049517782 scopus 로고    scopus 로고
    • 2010 Focused Update of ESC Guidelines on device therapy in heart failure: an update of the 2008 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure and the 2007 ESC Guidelines for cardiac and resynchronization therapy. Developed with the special contribution of the Heart Failure Association and the European Heart Rhythm Association
    • PID: 20974767
    • Dickstein K, Vardas PE, Auricchio A et al (2010) 2010 Focused Update of ESC Guidelines on device therapy in heart failure: an update of the 2008 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure and the 2007 ESC Guidelines for cardiac and resynchronization therapy. Developed with the special contribution of the Heart Failure Association and the European Heart Rhythm Association. Europace 12:1526–1536. doi:10.1093/europace/euq392
    • (2010) Europace , vol.12 , pp. 1526-1536
    • Dickstein, K.1    Vardas, P.E.2    Auricchio, A.3
  • 5
    • 77956932471 scopus 로고    scopus 로고
    • Contributions of remote monitoring to the follow-up of implantable cardioverter-defibrillator leads under advisory
    • PID: 20591841
    • Guedon-Moreau L, Chevalier P, Marquie C et al (2010) Contributions of remote monitoring to the follow-up of implantable cardioverter-defibrillator leads under advisory. Eur Heart J 31:2246–2252. doi:10.1093/eurheartj/ehq203
    • (2010) Eur Heart J , vol.31 , pp. 2246-2252
    • Guedon-Moreau, L.1    Chevalier, P.2    Marquie, C.3
  • 6
    • 50949090502 scopus 로고    scopus 로고
    • Prognostic importance of defibrillator shocks in patients with heart failure
    • COI: 1:CAS:528:DC%2BD1cXhtVymurbN, PID: 18768944
    • Poole JE, Johnson GW, Hellkamp AS et al (2008) Prognostic importance of defibrillator shocks in patients with heart failure. N Engl J Med 359:1009–1017
    • (2008) N Engl J Med , vol.359 , pp. 1009-1017
    • Poole, J.E.1    Johnson, G.W.2    Hellkamp, A.S.3
  • 7
    • 84886409725 scopus 로고    scopus 로고
    • Survival after shock therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy-defibrillator recipients according to rhythm shocked. The ALTITUDE survival by rhythm study
    • PID: 23810882
    • Powell BD, Saxon LA, Boehmer JP et al (2013) Survival after shock therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy-defibrillator recipients according to rhythm shocked. The ALTITUDE survival by rhythm study. J Am Coll Cardiol 62:1674–1679. doi:10.1016/j.jacc.2013.04.083
    • (2013) J Am Coll Cardiol , vol.62 , pp. 1674-1679
    • Powell, B.D.1    Saxon, L.A.2    Boehmer, J.P.3
  • 8
    • 78650692944 scopus 로고    scopus 로고
    • Long-term outcome after ICD and CRT implantation and influence of remote device follow-up: the ALTITUDE survival study
    • PID: 21098452
    • Saxon LA, Hayes DL, Gilliam FR et al (2010) Long-term outcome after ICD and CRT implantation and influence of remote device follow-up: the ALTITUDE survival study. Circulation 122:2359–2367. doi:10.1161/CIRCULATIONAHA.110.960633
    • (2010) Circulation , vol.122 , pp. 2359-2367
    • Saxon, L.A.1    Hayes, D.L.2    Gilliam, F.R.3
  • 9
    • 0037022208 scopus 로고    scopus 로고
    • Quality of life in the antiarrhythmics versus implantable defibrillators trial: impact of therapy and influence of adverse symptoms and defibrillator shocks
    • PID: 11827924
    • Schron EB, Exner DV, Yao Q et al (2002) Quality of life in the antiarrhythmics versus implantable defibrillators trial: impact of therapy and influence of adverse symptoms and defibrillator shocks. Circulation 105:589–594
    • (2002) Circulation , vol.105 , pp. 589-594
    • Schron, E.B.1    Exner, D.V.2    Yao, Q.3
  • 10
    • 84947869344 scopus 로고    scopus 로고
    • Reduction of inappropriate ICD therapies in patients with primary prevention of sudden cardiac death: DECREASE study
    • Schwab JO, Bonnemeier H, Kleemann T et al (2015) Reduction of inappropriate ICD therapies in patients with primary prevention of sudden cardiac death: DECREASE study. Clin Res Cardiol Off J Ger Card Soc 104:1021–1032. doi:10.1007/s00392-015-0870-z
    • (2015) Clin Res Cardiol Off J Ger Card Soc , vol.104 , pp. 1021-1032
    • Schwab, J.O.1    Bonnemeier, H.2    Kleemann, T.3
  • 11
    • 52949096237 scopus 로고    scopus 로고
    • Morphology discrimination in implantable cardioverter-defibrillators: consistency of template match percentage during atrial tachyarrhythmias at different heart rates
    • PID: 18662939
    • Theuns DAMJ, Rivero-Ayerza M, Goedhart DM et al (2008) Morphology discrimination in implantable cardioverter-defibrillators: consistency of template match percentage during atrial tachyarrhythmias at different heart rates. Europace 10:1060–1066. doi:10.1093/europace/eun194
    • (2008) Europace , vol.10 , pp. 1060-1066
    • Theuns, D.A.M.J.1    Rivero-Ayerza, M.2    Goedhart, D.M.3
  • 12
    • 84866661097 scopus 로고    scopus 로고
    • 2012 ACCF/AHA/HRS focused update of the 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines
    • PID: 22975230
    • Tracy CM, Epstein AE, Darbar D et al (2012) 2012 ACCF/AHA/HRS focused update of the 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol 60:1297–1313. doi:10.1016/j.jacc.2012.07.009
    • (2012) J Am Coll Cardiol , vol.60 , pp. 1297-1313
    • Tracy, C.M.1    Epstein, A.E.2    Darbar, D.3
  • 13
    • 55249106435 scopus 로고    scopus 로고
    • Tools and strategies for the reduction of inappropriate implantable cardioverter defibrillator shocks
    • PID: 18708639
    • Tzeis S, Andrikopoulos G, Kolb C, Vardas PE (2008) Tools and strategies for the reduction of inappropriate implantable cardioverter defibrillator shocks. Europace 10:1256–1265. doi:10.1093/europace/eun205
    • (2008) Europace , vol.10 , pp. 1256-1265
    • Tzeis, S.1    Andrikopoulos, G.2    Kolb, C.3    Vardas, P.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.